LARGE COMBUSTION PLANTS REGULATIONS *
Table of Provisions (15)
Statutory Text (15 Articles)
SUBSIDIARY LEGISLATION 549.56
LARGE COMBUSTION PLANTS REGULATIONS *
23rd March, 2010
LEGAL NOTICE 172 of 2010.
(1) The title of these regulations is the Large Combustion
Plants Regulations.
(2) These regulations transpose Directive 2001/80/EC of the
European Parliament and of the Council of 23 October 2001 on the
limitation of emissions of certain pollutants into the air from large
combustion plants.
(3) These regulations apply to combustion plants designed for
production of energy with the exception of those which make direct
use of the products of combustion in the manufacturing process, if
their rated thermal input is equal to or greater than 50 MWTH,
irrespective of the type of fuel used (solid, liquid or gaseous).
These regulations shall not apply to the following combustion
plants
(a) plants in which the products of combustion are used
for the direct heat, drying, or any other treatment of
objects or materials e.g. reheating furnaces, furnaces
for heat treatment;
(b) post-combustion plants i.e. any technical apparatus
designed to purify the waste gases by combustion
which is not operated as an independent combustion
plant;
(c) facilities for the regeneration of catalytic cracking
catalysts;
(d) facilities for the conversion of hydrogen sulphide into
sulphur;
(e) reactors used in the chemical industry;
(f)
coke battery furnaces;
(g) cowpers;
(h) any technical apparatus used in the propulsion of a
vehicle, ship or aircraft;
(i)
gas turbines used on offshore platforms;
(j)
gas turbines for which development planning
permission was issued before 27 November 2002
provided that they were put into operation no later
*these regulations were revoked by Legal Notice 11 of 2013 - but see regulation 23(1)
of the said legal notice, reproduced hereunder
"23.(1) The Large Combustion Plants Regulations, 2010, hereinafter referred to as
"the revoked regulations", are revoked with effect from 1 January 2016; however
regulations 1(3)(j), 3 and 4 as well as Schedules I to VII of the revoked regulations
shall be applicable to the combustion plants within the scope of regulation 5(3) of
these regulations, until the 01 January 2020.".
than 27 November 2003
without
prejudice
to
regulations 9(1), 14 and 17;
(k) plants powered by diesel engines irrespective of the
fuel used or petrol and gas engines.
EMISSION LIMIT VALUES FOR SOLID FUELS
Emission limit values expressed in mg.Nm -3 (at an oxygen content of 6%) to be
applied by ‘new’ and ‘existing’ plants pursuant to regulation 3(1) and regulation
4(1)
A.
Emission Limit values for SO 2
Rated Thermal Input (P TH )
Emission Limit Value (ELV)
2000 Mg SO 2 .Nm -3
50MW TH < P TH < 100 MW TH
calculated using the equation: ELV(mg SO 2 .Nm -3 ) = -
100MW TH < P TH < 500MW TH
4P TH + 2400
400mg SO 2 .Nm -3
P TH > 500MW TH
See figure 1 below
Figure 1: Emission Limit Values for SO 2 at 6% O 2 .
B.
Emission limit values for NO X measured as NO 2 .
Rated Thermal Input (P TH )
Emission Limit Value
Emission Limit Value (ELV)
(ELV)
as from 01 January 2016
600 mg NO 2 .Nm -3
600 mg NO 2 .Nm -3
50MW TH < P TH < 100 MW TH
500 mg NO 2 .Nm -3
200 mg NO 2 .Nm -3
P TH > 500MW TH
C.
Emission limit values for dust .
Rated Thermal Input (P TH )
Emission Limit Value (ELV)
100 mg dust .Nm -3
P TH < 500 MW TH
50 mg dust .Nm -3 (1)
P TH > 500 MW TH
A limit value of 100 mg dust.Nm -3 may be applied to plants permitted pursuant to
regulation 4(1) with a rated thermal input greater or equal to 500 MW TH burning solid fuel
with a heat content less than 5800 kJ.kg -1 (net heat value), a moisture content greater than
45% by weight, a combined moisture and ash content greater than 60% and a calcium oxide
content greater than 10%.
For the purpose of these regulations and unless the context
otherwise requires
"biomass" means products consisting of any whole or part of
vegetable matter from agriculture or forestry which can be used as
a fuel for the purpose of recovering its energy content and the
following waste used as fuel
(a) vegetable waste from agriculture and industry;
(b) vegetable waste from the food processing industry, if
the heat generated is recovered;
(c) fibrous vegetable waste from virgin pulp production
and from the production of paper from pulp, if it is co-
incinerated at the place of production and the heat
generated is recovered;
(d) cork waste;
(e) wood waste with the exception of wood waste which
may contain halogenated organic compounds or heavy
metals as a result of treatment with wood preservatives
or coating, and which includes in particular such wood
waste originating from construction and demolition
waste;
"combustion unit" means any plant in which fuel is oxidised in
order to use the heat thus generated;
"competent authority" means the Environment and Resources
Authority;
"director" means the Director of the Environment Protection
Directorate of the Environment and Resources Authority and
includes any person or body of persons acting on his behalf or
under his authority;
" e m i s s i o n " m e a n s t h e d i s c h a rg e o f s u b s t a n c e s f r o m t h e
combustion plant to air;
"emission limit value" means the permissible mass concentration
of an air pollutant in the waste gas discharged by the combustion
plant expressed in mg.Nm-3 or ng.Nm-3 as the case may be. The
mass concentration measured in the waste gas shall be expressed at
standard conditions according to the following equation
T
101.3
EMISSION LIMIT VALUES FOR SOLID FUELS
Emission limit values expressed in mg.Nm -3 (at an oxygen content of 6%) to be
applied by ‘new’ plants pursuant to regulations 3(2)
A.
Emission Limit values for SO 2 .
Type of Fuel
50 MW TH < P TH < 100 100 MW TH < P TH < 300
P TH > 300 MW TH
MW TH
MW TH
200 mg SO 2 .Nm -3
200 mg SO 2 .Nm -3
200 mg SO 2 .Nm -3
Biomass
850 mg SO 2 .Nm -3
200 mg SO 2 .Nm -3
200 mg SO 2 .Nm -3
General case
B.
Emission Limit values for NO X .
Type of Fuel
50 MW TH < P TH < 100 100 MW TH < P TH < 300
P TH > 300 MW TH
MW TH
MW TH
-3
300 mg NO 2 .Nm -3
200 mg NO 2 .Nm -3
Biomass
400 mg NO 2 .Nm
-3
200 mg NO 2 .Nm -3
200 mg NO 2 .Nm -3
General case
400 mg NO 2 .Nm
Where PTH is the rated thermal input of the combustion plant in MWTH.
C.
Emission Limit values for dust.
Rated Thermal Input (P TH )
Emission Limit Value (ELV)
50 mg dust .Nm -3
50 > P TH > 100 MW TH
30 mg dust .Nm -3
P TH > 100 MW TH
EMISSION LIMIT VALUES FOR LIQUID FUELS
Emission limit values expressed in mg.Nm -3 (at an oxygen content of 3%) to be
applied by ‘new’ and ‘existing’ plants pursuant to regulation 3(1) and regulation
4(1).
A.
Emission Limit values for SO 2
Rated Thermal Input (P TH )
Emission Limit Value (ELV)
1700 Mg SO 2 .Nm -3
50MW TH < P TH < 300 MW TH
calculated using the equation: ELV(mg SO 2 .Nm -3 ) = -
300MW TH < P TH < 500MW TH
6.5P TH + 3650
400mg SO 2 .Nm -3
P TH > 500MW TH
See figure 2 below
Figure 2: Emission Limit Values for SO 2 at 3% O 2 .
B.
Emission limit values for NO X measured as NO 2 .
Rated Thermal Input (P TH )
Emission Limit Value (ELV)
450 mg NO 2 .Nm -3
50MW TH < P TH < 500 MW TH
400mg NO 2 .Nm -3
P TH > 500MW TH
C.
Emission limit values for dust.
Rated Thermal Input (P TH )
Emission Limit Value (ELV)
50 mg dust .Nm -3
ALL plants
EMISSION LIMIT VALUES FOR LIQUID FUELS
Emission limit values expressed in mg.Nm -3 (at an oxygen content of 3%) to be
applied by ‘new’ and ‘existing’ plants pursuant to regulation 3(2).
A.
Emission Limit values for SO 2 .
Rated Thermal Input (P TH )
Emission Limit Value (ELV)
850 Mg SO 2 .Nm -3
50MW TH < P TH < 100 MW TH
calculated using the equation: ELV(mg SO 2 .Nm -3 ) = -
100MW TH < P TH < 300MW TH
6.5P TH + 500
200mg SO 2 .Nm -3
P TH > 300MW TH
B.
Emission Limit values for NO X .
Rated Thermal Input (P TH )
Emission Limit Value (ELV)
400 mg NO 2 .Nm -3
50MW TH < P TH < 100 MW TH
200mg NO 2 .Nm -3
100MW TH < P TH < 300 MW TH
200mg NO 2 .Nm -3
P TH > 300MW TH
C.
Emission Limit values for dust.
Rated Thermal Input (P TH )
Emission Limit Value (ELV)
50 mg dust .Nm -3
50 > P TH < 100 MW TH
30 mg dust .Nm -3
P TH > 100 MW TH
Where P TH is the rated thermal input of the combustion plant in MW TH .
EMISSION LIMIT VALUES FOR GASEOUS FUELS
Emission limit values expressed in mg.Nm -3 (at an oxygen content of 3%) to be
applied by ‘new’ plants pursuant to regulation 3(1) and regulation 4(1).
A.
Emission Limit values for SO 2 .
Type of Fuel
Emission Limit Value (ELV)
35 mg SO 2 .Nm -3
Gaseous fuels in general
5 mg SO 2 .Nm -3
Liquefied gas
L o w c a l o r i f i c g a s e s f r o m 800mg SO 2 .Nm -3
gasification of refinery residues,
coke oven gas, blast furnace gas
Gas from the gasification of coal 35 mg SO 2 .Nm -3
B.
Emission Limit values for NO X .
Rated Thermal Input (P TH )
Emission Limit Value (ELV)
300 mg NO 2 .Nm -3
50MW TH < P TH < 500 MW TH
200mg NO 2 .Nm -3
P TH > 500MW TH
C.
Emission Limit values for dust.
Type of Fuel
Emission Limit Value (ELV)
5 mg dust .Nm -3
As a rule
10 mg dust .Nm -3
For blast furnace gas
For gases produced by the steel 50 mg dust .Nm -3
industry which can be used
elsewhere
EMISSION LIMIT VALUES FOR GASEOUS FUELS
Emission limit values expressed in mg.Nm -3 (at an oxygen content of 3%) to be
applied by ‘new’ plants pursuant to regulation 3(2).
A.
Emission Limit values for SO 2 .
Type of Fuel
Emission Limit Value (ELV)
35 mg SO 2 .Nm -3
Gaseous fuels in general
5 mg SO 2 .Nm -3
Liquefied gas
Low calorific gases from coke 400mg SO 2 .Nm -3
oven
Low calorific gases from blast 200 mg SO 2 .Nm -3
furnaces
B.
Emission Limit values for NO X .
Type of Fuel
50MW TH < P TH < 300 MW TH
P TH > 300MW TH
150 mg NO 2 .Nm -3
100 mg NO 2 .Nm -3
Natural gas (naturally occurring
methane with no more than 20%
by volume of inerts and other
constituents)
200 mg NO 2 .Nm -3
200 mg NO 2 .Nm -3
Other gases
Where P TH is the rated thermal input of the combustion plant in MW TH .
C.
Emission Limit values for dust.
Type of Fuel
Emission Limit Value (ELV)
5 mg dust .Nm -3
As a rule
10 mg dust .Nm -3
For blast furnace gas
For gases produced by the steel 30 mg dust .Nm -3
industry which can be used
elsewhere
EMISSION LIMIT VALUES FOR GAS TURBINES
Emission limit values are expressed in mg.m -3 (at an oxygen content of 15%) to be
applied by a single gas turbine unit pursuant to regulation. The limit values apply
only above 70% of the load.
Fuels
Emission Limit Value (ELV)
Natural gas (naturally occurring methane with not more 50 mg NO 2 .Nm -3 (1)
than 20% (by volume) of inerts and other constituents)
Liquid fuels (emission limit value applies to gas turbines 120 mg NO 2 .Nm -3
firing light and middle distillates)
120 mg NO 2 .Nm -3
Gaseous fuels other than natural gas
(1) 75 mg NO2.Nm-3 in the following cases
a.
gas turbines used in combined heat and power systems having an overall
efficiency greater than 75%;
b.
gas turbines used in combined cycle plants having an annual overall electrical
efficiency greater than 55%; and
c.
gas turbines for mechanical drives.
For single gas turbines not falling into any of the above categories, but having an efficiency
greater than 35% (determined at ISO base load conditions), the emission limit value shall be
1.42 where is the gas turbine efficiency expressed as a percentage (and at ISO base load
conditions).
Gas turbines for emergency use that operate less than 500hrs per year are excluded from
these limit values. The operator of such plants is required to submit each year to the
competent authority a record of such used time.
DEROGATIONS AS PER REGUALTION 9(5) AND (6)
Notification of a temporary derogation from compliance with
Large Combustion Plants Emission Limit Values.
In view of the written request by [person submitting the request] on behalf of
[operator], dated [date], I [Name of Director], in my capacity as Director of
Environment Protection have examined all the information handed by [operator]
together with the above mentioned request and have decided to allow for a
derogation from [type of derogation to be applied to plant] for the [name of the
plant] operated by [name of operator] having its registered address at [registered
address of the operator] and subject to the IPPC Permit [IPPC permit number] issued
on the [date of issue of the permit] for a period not exceeding [time].
This derogation is subject to the following conditions
[Signature]
[Name, SURNAME]
Director of Environment Protection
Attached a copy of the request for derogation and technical information related to
the case.
REQUIREMENTS FOR THE AUTOMATED MEASURING SYSTEMS
AND FOR THE VALIDATION OF RESULTS
The value of the 95% confidence interval of a single measured result shall not
exceed the following percentages of the emission limit values
Sulphur dioxide
20%
Nitrogen oxides
20%
Total dust
30%
The validated hourly and daily mean values shall be determined from the
measured hourly average values after having subtracted the value of the confidence
interval specified above.
Any day in which more than three hourly average values are invalid due to
malfunction of the automated measuring system shall be invalidated. If more than 10
days a year are invalidated for such situations, the competent authority shall require
the operator to take adequate measures to improve the reliability of the automated
measuring system.
INFORMATION TO BE REPORTED WITH THE EMISSIONS INVENTORY
Emissions inventories prepared by the operator under regulation 17, shall include
the following information
Name of the Installation;
Name of the combustion plant;
Fuel Burn for the combustion plant (Mg.yr -1 )
Heat Value of the fuel fired by the combustion plant (GJ.Mg -1 )
Total annual load of sulphur dioxide for the combustion plant (Mg.yr -1 ).
Total annual load of nitrogen oxides for the combustion plant (Mg.yr -1 ).
Total annual load of dust for the combustion plant (Mg.yr -1 ).
Total annual pollutant loads shall be calculated as follows
d=365
avg
( WGF d [P] d ) [for leap years d=366]
d=1
Where
WGF d is the daily waste gas flow rate in Nm 3
[P] d avg is the daily average concentration of the pollutant in mg.Nm -3 .
INFORMATION TO BE REPORTED WITH THE OPERATING TIME
Reports on combustion plants operating time prepared by the operator under
regulation 17, shall include the following information
Name of the Installation;
Name of the combustion plant;
T O , the total combustion plant operating time (hr);
T R , the remaining combustion plant operating time (hr);
Where
T R = 20000 – T O
94 - O s
[P] M
[P] s =
P
100 - W 20.94 - O M
Where
[P]s is the mass concentration of the pollutant at standard
conditions.
[P]M is the mass concentration of the pollutant measured at the
temperature T in K, at a Pressure P in kPa, at a percentage flue gas
water vapour content of W and at a flue gas oxygen content of O M .
T is the actual flue gas temperature in K.
P is the actual flue gas pressure in kPa.
W is the percentage water vapour content of the flue gas.
OS is the standard oxygen content content by volume in the
waste gas which shall be 3% in the case of liquid and gaseous fuels,
6% in the case of solid fuels and 15% in the case of gas turbines.
O M is the measured oxygen content in the flue gas;
"existing combustion plant" means one or more combustion units
for which development planning permission was granted before 1
July 1987. Two or more combustion units shall be considered as a
single combustion plant if their waste gases are de facto discharged
through a common stack;
"flue" means a compartment or division of a stack for conveying
waste gases from the combustion plant to the outer air;
"fuel" means any solid, liquid or gaseous combustible material
used to fire the combustion unit with the exception of waste
covered by Waste Management (Incineration) Regulations, or any
subsequent regulations substituting those regulations;
"gas turbine plant" means any plant made up of a rotating
machine which converts thermal energy into mechanical work,
consisting mainly of a compressor, a thermal device in which fuel
is oxidised in order to heat the working fluid, and a turbine;
"multi-fuel firing combustion plant" means any combustion plant
which may be fired simultaneously or alternately by two or more
types of fuel;
"new combustion plant" means one or more combustion units for
which development planning permission was granted on or after 1
July 1987. Two or more combustion units shall be considered as a
single combustion plant if their waste gases are de facto discharged
through a common stack or if taking technical and economic
factors into account, their waste gases could in the judgement of
the competent authority be discharged through a common stack;
"operator" means any natural or legal person who operates the
combustion plant, or who has been delegated decisive economic
power over it;
"permit" means the permit issued under regulation 4 of the
Integrated Pollution Prevention and Control Regulations;
"pollutant" means a substance which has been directly or
indirectly i ntro duced int o th e at mosphere as a resultin g of
anthropogenic activity and which has deleterious effects of such a
nature as to endanger human health, harm living resources,
ecosystems and material property, and impair amenities or interfere
with other legitimate uses of the environment;
"stack or chimney" means the structure rising above roof level
and which provides a conduit for waste gases from the combustion
plant and which may embody one or more flues;
"rated thermal input" means the rate at which fuel can be burned
at the maxim um continuous rating of the combustion plant
multiplied by the net heat value of the fuel expressed as megawatts
thermal (MWTH);
"waste gas" means the carrier gas together with any solid, liquid
or gaseous emissions which are discharged with it; the waste gas
volume flow rate shall be expressed in metres cubed per hour at
standard conditions, i.e. at a temperature of 273K and at a pressure
of 101.3 kPa, after correction for the water vapour content, and
hereinafter referred to as normal metre cubed per hour or Nm 3 .hr -1 .
3. (1) Permits for ‘new’ combustion plants which have been
granted development planning consent before 27 November 2002
provided that they are in operation no later than 27 November
2003, shall include conditions relating to compliance with the
emission limit values which shall not be higher than those in
(a) Schedule I for plants firing solid fuels;
(b) Schedule III for plants firing liquid fuels; and
(c) Schedule V for plants firing gaseous fuels.
(2) Permits for ‘new’ combustion plants not covered by sub-
regulation (1) shall include conditions relating to compliance with
the emission limit values which shall not be higher than those in
(a) Schedule II for plants firing solid fuels;
(b) Schedule IV for plants firing liquid fuels; and
(c) Schedule VI for plants firing gaseous fuels.
4. (1) Permits for ‘existing’ plants shall include conditions
relating to compliance with the emission limit values which shall
not be higher than those in
(a) Schedule I for plants firing solid fuels;
(b) Schedule III for plants firing liquid fuels; and
(c) Schedule V for plants firing gaseous fuels.
(2) By way of derogation from sub-regulation (1), ‘existing’
combustion plants may be exempted from compliance with the
above mentioned requirements if the operator has submitted by 30
June 2004 a written declaration to the competent authority stating
that the plants in question will not be operated for more than 20000
operational hours starting on the 1 January 2008 and ending no
later than 31 December 2015.
(3) The operators of ‘existing’ combustion plants covered by
the exemption in sub-regulation (2) are required to submit to the
competent authority a record of the used and unused time allowed
for the plants’ operational life. In calculating the operational time
used by the ‘existing’ combustion plant the operator shall consider
the combustion plant to be operating when any part of it operates,
irrespective of the load factor.
5. Permits for gas turbines within the scope of this regulation,
shall include conditions relating to compliance with the emission
limit values which shall not be higher than those in Schedule VII.
6. The competent authority may impose limit values stricter
than those in regulations 3, 4, and 5 or impose emission limit
values on plants exempt from this requirement through regulation
4(2) in order to ensure compliance with
(a) the Ambient Air Quality Regulations, and any
subsequent regulations dealing with the ambient levels
of atmospheric pollutants;
(b) any additional requirements arising out of the
Integrated Pollution Prevention and Control
Regulations, particularly the requirement to use the
best available techniques; and
(c) any other regulations issued under the Environment
Protection Act and deemed relevant by the competent
authority.
7. (1) Combustion plants, of a rated thermal input equal to or
greater than 400 MW, shall be subject to a limit value for sulphur
dioxide emissions of 800 mg SO 2 .Nm -3 if they do not operate for
more than the following number of hours a year (rolling average
over a period of five years)
(a) 2,000 hours till 31 December 2015;
(b) 1,500 hours from the 1 January 2016 onwards.
(2) This regulation shall not apply to combustion plants subject
to the permitting requirements in regulation 3(2).
8. Operators of combustion plants subject to the permitting
requirements of regulation 3(2) shall investigate the technical and
economic feasibility of providing for the combined generation of
heat and power. Should this feasibility be confirmed the operators
will be required to develop their installations accordingly, keeping
in mind the market and distribution situation.
9. (1) Permits for combustion plants within the scope of these
regulations, shall include conditions on procedures relating to
malfunction or break down of the abatement equipment.
(2) In the case of a breakdown the operator shall operate the
plant using low polluting fuels and if this is not enough to achieve
the relevant limit values, the operator shall reduce or close down
operations if a return to normal operation is not achieved within
twenty-four hours.
(3) The competent authority shall be notified within forty-eight
hours of the occurrence of such breakdown or malfunction.
(4) In no circumstance shall the cumulative duration of
unabated operation in any twelve month period exceed one hundred
and twenty hours. The Director may allow exceptions to the limits
of twenty-four hours and one hundred and twenty hours above in
cases where in his judgement
(a) there is an overriding need to maintain energy
supplies; or
(b) the plant with the breakdown would be replaced for a
limited period by another plant which would cause an
overall increase in emissions.
(5) The Director may allow a suspension for a maximum of six
months from the obligation to comply with the emission limit
values provided for in regulations 3 and 4 for sulphur dioxide in
respect of a combustion plant which to this end normally uses low-
sulphur fuel, in cases where the operator is unable to comply with
these limit values due to an interruption in the supply of low-
sulphur fuel resulting from a serious shortage.
(6) The Director may allow a derogation from the obligation to
comply with the emission limit values provided for in regulations 3
and 4 in cases where a plant which normally uses only gaseous
fuel, and which would otherwise need to be equipped with a waste
gas purification facility, has to resort exceptionally, and for a
period not exceeding ten days except where there is an overriding
need to maintain energy supplies, to the use of other fuels because
of a sudden interruption in the supply of gas. The competent
authority shall immediately be informed of each specific case as it
arises.
(7) In the cases mentioned in sub-regulations (5) and (6), the
operator shall inform the Director in writing of the need to apply
for the exemptions provided for in these two sub-regulations as
soon as the cases in question arise. In doing so the operator shall
forward all the relevant technical information as well as any other
information deemed necessary by the competent authority. The
competent authority shall, at its discretion issue the temporary
derogation according to the provisions of the above mentioned sub-
regulations as per notification in Schedule VIII. The competent
authority shall publish this notification together with all the
information forwarded to it by the operator, on the subsequent issue
of the Gazette.
10. (1) Permits for combustion plants made up of multifiring
units involving the simultaneous use of two or more fuels shall
include conditions relating to compliance with emission limit
values which shall be established as follows
(a) by taking the emission limit value relevant to each
individual fuel and pollutant corresponding to the
rated thermal input of the combustion plant as given in
Schedules I, II, III, IV, V, VI and VII;
(b) by determining fuel-weighted emission limit values,
which are obtained by multiplying the above
individual emission limit value by the thermal input
delivered by each fuel, the product of multiplication
being divided by the sum of the thermal inputs
delivered by all fuels; and
(c) by aggregating the fuel-weighted limit values.
(2) In multi-firing units using distillation and conversion
residues from crude-oil refining for own consumption, alone or
with other fuels, the provisions for the fuel with the highest
emission limit value (determinative fuel) shall apply
notwithstanding sub-regulation (1) of this regulation, if during the
operation of the combustion plant the proportion contributed by
that fuel to the sum of the thermal inputs delivered by all fuels is at
least 50%. Where the proportion of the determinative fuel is lower
than 50%, the emission limit value is determined on a pro rata
basis of the heat input supplied by individual fuels in relation to the
sum of the thermal inputs delivered by all fuels as follows
(a) by taking the emission limit value relevant for each
individual fuel and pollutant corresponding to the
rated thermal input of the combustion plant as given in
Schedules I, II, III, IV, V, VI and VII;
(b) by calculating the emission limit value of the
determinative fuel (fuel with the highest emission limit
value according to Schedules I, II, III, IV, V, VI and
VII and in the case of two fuels having the same
emission limit value, the fuel with the higher thermal
input); this value is obtained by multiplying the
emission limit value laid down in Schedules I, II, III,
IV, V, VI and VII for that fuel by a factor of two, and
subtracting from this product the emission limit value
of the fuel with the lowest emission limit value;
(c) by determining the fuel-weighted emission limit
values, which are obtained by multiplying the
calculated fuel emission limit value by the thermal
input of the determinative fuel and other individual
emission limit values by the thermal input delivered by
each fuel, the product of multiplication being divided
by the sum of the thermal inputs delivered by all fuels;
and
(d) by aggregating the fuel-weighted emission limit
values.
(3) As an alternative to sub-regulation (2), the following
average emission limit values for sulphur dioxide may be applied
(irrespective of the fuel combination used)
(a) for the plants referred to in regulations 3(1) and 4(1)
1000 mg SO 2 .Nm -3 , averaged all over such plants
within the refinery; and
(b) for the ‘new’ plants referred to in regulation 3(2): 600
mg SO 2 .Nm -3 , averaged all over such plants within the
refinery, with the exception of gas turbines
Provided that the competent authority shall ensure that the
application of this provision does not lead to an increase in
emissions from existing plants.
(4) In the case of combustion plants with multifiring units
involving the alternative use of two or more fuels, the emission
limit values to be included in the permit shall be those in Schedules
I, II, III, IV, V, VI and VII corresponding to each fuel used.
(5) The emission limit values determined according to the
procedures prescribed by sub-regulations (1) to (4) are the highest
permissible limit values. Permits issued under regulation 4 of
Integrated Pollution Prevention and Control Regulations may
include stricter emission limit values, particularly in order to
ensure compliance with the BAT requirement.
11. (1) The operators of combustion plants having a rated
electrical output of 300 MW or more and which were issued with a
permit after the 13 May 2009, shall assess whether
(a) suitable geological storage sites for carbon dioxide are
available; and
(b) transport facilities are technically and economically
feasible; and
(c) it is technically and economically feasible to retrofit
for carbon dioxide capture.
(2) If the conditions in sub-regulation (1) are met, the
competent authority shall ensure that the permits issued after the 13
May 2009 include a clause on the setting aside of a suitable space
on the installation site for the equipment necessary to capture and
compress carbon dioxide.
The competent authority shall determine whether the
conditions are met on the basis of the assessment referred to in the
first paragraph of this sub-regulation and other available
information, particularly concerning the protection of the
environment and human health.
12. (1) Permits for combustion plants within the scope of
these regulations shall include conditions related to the minimum
stack height in order to safeguard human health and the
environment.
(2) The stack height shall be calculated according to the
guidance document issued by the competent authority.
13. Where a combustion plant is extended by at least 50
MWTH, the applicable emission limit values shall not be higher to
those set out in Schedules II, IV and VI in respect of sulphur
dioxide, nitrogen oxides and dust.
14. (1) The operator shall monitor the concentrations of
sulphur dioxide, oxides of nitrogen and dust in the waste gases of
the combustion plants within the scope of these regulations.
(2) The operator shall monitor continuously through the use of
automated measurement systems the flue gases of the combustion
plants within the scope of these regulations for sulphur dioxide,
oxides of nitrogen and dust if the rated thermal input of the
combustion plant is 100 MW or more.
(3) In addition to the parameters in sub-regulation (2), the
operator shall monitor the relevant process operation parameters of
oxygen content, temperature, pressure and water vapour content.
The continuous measurement of the water vapour content shall not
be necessary if the sampled exhaust gas is dried prior to analysis.
(4) The operator shall monitor the flue gases of the combustion
plants within the scope of these regulations discontinuously for
sulphur dioxide, oxides of nitrogen and dust if they are not covered
by the monitoring requirement in subregulation (2).
(5) The sampling and analysis of the relevant pollutants and
process parameters as well as reference measurement methods to
calibrate automated measurement systems shall be carried out in
accordance with CEN standard methods. If CEN standards are not
available, ISO standards or any national standard method from any
of the Member Sates of the European Union can be used. In
addition, continuous measuring systems shall be subject to control
by means of parallel measurements with the reference methods at
least every year.
(6) The operator shall carry out any discontinuous monitoring
in accordance with the relevant CEN standards. In the absence of a
CEN standard method an ISO standard method or any national
standard method from any of the European Union Member States
can be used.
(7) Automated measuring
systems
are
subject
to
the
requirements in Schedule IX.
15. The operator shall inform the competent authority of the
results of the continuous measurements, the checking of the
measurement equipment, the individual measurements and all other
measurements within the time frames set by the permit.
16. (1) In the event of continuous measurements, the emission
limit values set out in Schedules I, III and V shall be regarded as
having been complied with if the evaluation of results indicates, for
operating hours within a calendar year, that
(a) none of the calendar monthly mean values exceeds the
emission limit values; and
(b) in the case of
(i)
sulphur dioxide and dust: 97% of all the forty-
eight hourly mean values do not exceed 110% of
the emission limit values; and
(ii) nitrogen oxides: 95% of all the forty-eight
hourly mean values do not exceed 110% of the
emission limit values.
(2) In the event of discontinuous measurements, the emission
limit values set out in Schedules I, II, III, IV, V, VI and VII shall be
regarded as having been complied with if the results of each of the
series of measurements do not exceed the emission limit values.
(3) The emission limit values set out in Schedules II, IV, VI
and VII shall be regarded, for operating hours within a calendar
year, as complied with if
(a) no validated daily average exceeds the relevant figures
prescribed in Schedules II, IV, VI and VII;
(b) 95% of all the validated hourly averages over the year
do not exceed 200% of the relevant figures prescribed
in Schedules II, IV and VI.
Validated values are determined as set out in Schedule IX.
(4) Provided that for the purpose of compliance with sub-
regulations (1) and (3), the periods referred to in regulation 9 as
well as start up and shut down periods shall be disregarded.
17. (1) The operator shall forward an emissions inventory on
a combustion plant basis by combustion plant basis, for sulphur
dioxide, nitrogen oxides and dust (as total suspended particulate).
The pollutant loads (in Mg) shall be calculated by adding the mass
of pollutant emitted by the combustion plant in question each day,
on the basis of volumetric flow rates of waste gases.
(2) Where discontinuous measurements are used, the operator
shall establish appropriate estimation procedures to the satisfaction
of the competent authority.
(3) The emissions inventory shall include the information in
Schedule X.
(4) For combustion plants operating on the derogation in
regulation 4(2), the operator shall report to the competent authority
on a yearly basis the operating time for each combustion plant
operating on this derogation. The report shall include the
information in Schedule XI.
18. A person shall be guilty on an offence under these
regulations if
(a) he fails to comply with any order lawfully given in
terms of any provision of these regulations; or
(b) he contravenes any restriction, prohibition or
requirement imposed by or under these regulations; or
(c) he conspires or attempts, or aids, or abets, any other
person by whatever means, including advertising,
counselling or procurement to contravene the
provisions of these regulations or to fail to comply
with any such provisions, including any order lawfully
given in terms of any of the provision of these
regulations, or to contravene any restriction,
prohibition or requirement imposed by or under the
said regulations.
19. Any person who commits an offence against these
regulations shall, on conviction, be liable
(a) on a first conviction to a fine (multa) of not less than
one thousand two hundred euro (€1,200) but not
exceeding two thousand three hundred euro (€2,300);
(b) on a second or subsequent convictions, to a fine
(multa) of not less than two thousand three hundred
euro (€2,300), but not exceeding eleven thousand six
hundred euro (€11,600) or to imprisonment for a term
not exceeding two years, or to both such fine and
imprisonment
Provided that whenever any person is found guilty of
committing an offence under these regulations by means of vehicle,
the owner of the said vehicle, where applicable, is held liable in the
same manner and degree
Provided further that the court shall order any person who
has been found guilty of committing an offence against these
regulations to pay for the expenses incurred by the public entities
and, or other persons acting on their behalf involved in the
i m p l e m en t a t i o n o f t h e s e r e g u l a t i o n s a n d r e s t i t u t i o n o f t h e
environment as a result of the said offence, the revocation of the
permit issued by the competent authority and the confiscation of
the corpus delicti.
20. (1) The provisions of articles 23 and 30(1) of the Criminal
Code shall, mutatis mutandis, apply to proceedings, in respect of
offences against these regulations, so however that the
disqualification from holding or obtaining a license, permit or
authority shall in no case be for less than one year.
(2) Notwithstanding the provisions of article 370 of the
C r i m i n a l C o d e , p r o c e e d i n g s f o r a n o ff e n c e a g a i n s t t h e s e
regulations shall be taken before the Court of Magistrates (Malta)
or the Court of Magistrates (Gozo), as the case may be, and shall be
in accordance with the provisions of the Criminal Code regulating
t h e p r o c e d u r e b e f o r e t h e sa i d c o u r t s a s c o u r t s o f c r i m i n a l
judicature.
(3) Notwithstanding the provisions of the Criminal Code, the
Attorney General shall always have a right of appeal to the Court of
Cri mi nal App eal f ro m any ju dgm ent gi ven by the Cou rt of
Magistrates (Malta) or the Court of Magistrates (Gozo) in respect
of proceedings for any offence against these regulations.