METHODS OF ANALYSIS FOR THE OFFICIAL CONTROL OF FEEDINGSTUFFS RULES *
Table of Provisions (12)
Statutory Text (12 Articles)
METHODS OF ANALYSIS FOR THE
OFFICIAL CONTROL OF FEEDINGSTUFFS
SUBSIDIARY LEGISLATION 437.77
METHODS OF ANALYSIS FOR THE OFFICIAL
CONTROL OF FEEDINGSTUFFS RULES *
12th August, 2005
LEGAL NOTICE 285 of 2005, as amended by Legal Notice 62 of 2006.
(1) The title of these rules is the Methods of Analysis for
the Official Control of Feedingstuffs Rules.
(2) The scope of these rules is to implement the rules found
under European Union Council Directive 76/372/EEC establishing
methods of analysis for the official control of feedingstuffs.
Amended by
L.N. 62 of 2006.
DETERMINATION OF AFLATOXIN B 1
A.
ONE-DIMENSIONAL THIN LAYER CHROMATOGRAPHIC METHOD
1. Purpose and scope
The method makes it possible to determine the level of aflatoxin B 1 in raw
materials and straight feedingstuffs. This method can not be applied in the presence
of citrus pulp. The lower limit of determination is 0,01 mg/kg (10 ppb).
In the presence of interfering substances it is necessary to repeat the analysis using
method B (high performance liquid chromatography).
2. Principle
The sample is subjected to extraction with chloroform. The extract is filtered, and
an aliquot portion taken and purified by column chromatography on silica gel. The
eluate is evaporated and the residue redissolved in a specific volume of chloroform
or of a mixture of benzene and acetonitrile. An aliquot portion of this solution is
subjected to thin-layer chromatography (TLC). The quantity of aflatoxin B 1 is
determined under UV irradiation of the chromatogram, either visually or by
fluorodensitometry, by comparison with known quantities of standard aflatoxin B 1 .
The identity of the aflatoxin B 1 extracted from the feedingstuff must be confirmed
by the procedure indicated.
3. Reagents
NB: All the reagents must be of ‘analytical reagent’ quality unless otherwise
stated.
3.1.
Acetone.
3.2.
Chloroform, stabilized with 0ꞏ5 to 1ꞏ0% of 96% ethanol (v/v).
3.3.
N-hexane.
3.4.
Methanol.
3.5.
Anhydrous diethyl ether, free from peroxides.
3.6.
Mixture of benzene and acetonitrile: 98/2 (v/v).
3.7.
Mixture of chloroform (3.2) and methanol (3.4): 97/3 (v/v).
3.8.
Silica gel, for column chromatography, particle size 0ꞏ05 to 0ꞏ20 mm.
3.9.
Absorbent cotton wool, previously defatted with chloroform, or glass
wool.
3.10.
Sodium sulphate, anhydrous, granular.
3.11.
Inert gas, e.g. nitrogen.
3.12.
1 N Hydrochloric acid.
3.13.
50% (v/v) sulphuric acid.
3.14.
Kieselguhr (hyflosupercel), washed in acid.
3.15.
Silica gel G-HR or equivalent, for TLC.
3.16.
Standard solution with about 0ꞏ1 µg of aflatoxin B 1 per ml in chloroform
(3.2) or the benzene/acetonitrile mixture (3.6), prepared and checked as indicated in
Section 7.
Standard solution for qualitative testing purposes containing about 0ꞏ1
µg of aflatoxin B 1 and B 2 per ml in chloroform (3.2) or the benzene/acetonitrile
mixture (3.6). These concentrations are given as a guide. They must be adjusted so
as to obtain the same intensity of fluorescence for both aflatoxins.
Developing solvents
Chloroform (3.2)/acetone (3.1): 9/1 (v/v), unsaturated tank;
Diethyl ether (3.5)/methanol (3.4)/water: 96/3/1 (v/v/v), unsaturated
Diethyl ether (3.5)/methanol (3.4)/water: 94/4ꞏ5/1ꞏ5 (v/v/v), saturated
Chloroform (3.2)/methanol (3.4): 94/6 (v/v), saturated tank;
Chloroform (3.2)/methanol (3.4): 97/3 (v/v), saturated tank.
For the purposes of these rules -
"the competent authority" means the Veterinary
Services within Malta as provided under article 2 of
the Veterinary Services Act, or any other authority to
which such responsibility has been delegated by the
Veterinary Services.
The competent authority shall require that analyses for
official controls of feedingstuffs, as regards their content of
aflatoxin B 1 , be carried out in accordance with the methods
described in the Schedule.
*These rules have been repealed by Legal Notice 37 of 2025.
Apparatus
Grinder-mixer.
Shaking apparatus or magnetic stirrer.
Fluted filter papers, Schleicher and Schüll No 588 or equivalent,
diameter: 24 cm
Glass tube for chromatography (internal diameter: 22 mm, length: 300
mm), with a PTFE cock and a 250-ml reservoir.
Rotary vacuum evaporator, with a 500-ml round-bottom flask.
500-ml conical flasks, with ground-glass stoppers.
TLC apparatus.
Glass plates for TLC, 200 × 200 mm, prepared as follows (the quantities
indicated are sufficient to cover five plates). Put 30 g of silica gel G-HR (3.15) into a
conical flask. Add 60 ml water, stopper and shake for a minute. Spread the
suspension on the plates so as to obtain a uniform layer 0ꞏ25 mm thick. Leave to dry
in the air and then store in a desiccator containing silica gel. At the time of use,
activate the plates by keeping them in the oven at 110ºC for one hour.
Ready-to-use plates are suitable if they give results similar to those obtained with
the plates prepared as indicated above.
Long-wavelength (360 nm) UV lamp. The intensity of irradiation must
make it possible for a spot of 1 ng of aflatoxin B 1 to be still clearly distinguished on
a TLC plate at a distance of 10 cm from the lamp.
10 ml graduated tubes with polyethylene stoppers.
UV spectrophotometer.
Fluorodensitometer (optional).
Procedure
Preparation of the sample (see under ‘Observations’, Part C, point 1).
Grind the sample so that the whole of it will pass through a sieve with a 1-mm
mesh (in accordance with recommendation ISO R 565).
Extraction
Put 50 g of ground, homogenized sample into a 500-ml conical flask (4.6). Add 25
g of Kieselguhr (3.14), 25 ml of water and 250 ml of chloroform (3.2). Stopper the
flask, shake or stir for 30 minutes with the apparatus (4.2) and filter through a fluted
filter paper (4.3). Discard the first 10 ml of the filtrate and then collect 50 ml.
5.3.
Column clean-up
Insert into the lower end of a chromatography tube (4.4) a cotton or glass wool
plug (3.9), fill two-thirds of the tube with chloroform (3.2) and add 5 g of sodium
sulphate (3.10).
Check that the upper surface of the sodium sulphate layer is flat, thenadd 10 g of
silica gel (3.8) in small portions. Stir carefully after each addition to eliminate air
bubbles. Leave to stand for 15 minutes and then carefully add 15 g of sodium
sulphate (3.10). Let the liquid fall until it is just above the upper surface of the
sodium sulphate layer.
Mix the 50 ml of extract collected in 5.2 with 100 ml of n-hexane (3.3) and
quantitatively transfer the mixture to the column. Let the liquid fall until it is just
above the upper surface of the sodium sulphate layer. Discard this washing. Then
add 100 ml of diethylether (3.5) and again allow it to fall to the upper surface of the
sodium sulphate layer. During these operations see that the rate of flow is 8 to 12 ml
per minute and that the column does not run dry. Discard the liquid that comes out.
Then elute with 150 ml of the chloroform/methanol mixture (3.7) and collect the
whole of the eluate.
Evaporate the latter almost to dryness at a temperature not exceeding 50ºC and
under a stream of inert gas (3.11) with the rotary evaporator (4.5). Quantitatively
transfer the residue, using chloroform (3.2) or the benzeneacetonitrile mixture (3.6),
to a 10 ml graduated tube (4.10). Concentrate the solution under a stream of inert gas
(3.11) and then adjust the volume to 2 ml with chloroform (3.2) or the benzene/
acetonitrile mixture (3.6).
5.4.
Thin-layer chromatography
Spot on a TLC plate (4.8), 2 cm from the lower edge and at intervals of 2 cm, the
volumes indicated below of the standard solution and the extract
- 10, 15, 20, 30 and 40 µl of the standard aflatoxin B 1 solution (3.16);
- 10 µl of the extract obtained in 5.3 and, superimposed on the same point, 20 µl of
the standard solution (3.16);
- 10 and 20 µl of the extract obtained in 5.3.
Develop the chromatogram in the dark with one of the developing solvents (3.18).
The choice of the solvent must be made beforehand, by depositing 25 µl of the
qualitative standard solution (3.17) on the plate and checking that, when developed,
aflatoxin B 1 and B 2 are completely separated. Let the solvents evaporate in the dark
and then irradiate with UV light, placing the plate 10 cm from the lamp (4.9). The
spots of aflatoxin B 1 give a blue fluorescence.
5.5.
Quantitative determinations
Determine either visually or by fluorodensitometry as indicated below.
5.5.1.
Visual measurements
Determine the quantity of aflatoxin B 1 in the extract by matching the fluorescence
intensity of the extract spots with that of one of the standard solution spots.
Interpolate if necessary. The fluorescence obtained by the superimposition of the
extract on the standard solution must be more intense than that of the 10 µl of extract
and there must not be more than one visible spot. If the fluorescence intensity given
by the 10 µl of extract is greater than that of the 40 µl of standard solution, dilute the
extract 10 or 100 times with chloroform (3.2) or the benzene/acetonitrile mixture
(3.6) before subjecting it again to thin-layer chromatography.
5.5.2.
Measurements by fluorodensitometry
Measure the fluorescence intensity of the aflatoxin B 1 spots with the
fluorodensitometer (4.12) at an excitation wavelength of 365 nm and an emission
wavelength of 443 nm. Determine the quantity of aflatoxin B 1 in the extract spots by
comparison of their fluorescence intensities with that of the standard aflatoxin B 1
spots.
5.6.
Confirmation of the identity of aflatoxin B 1
Confirm the identity of the aflatoxin B 1 in the extract by the processes indicated
below.
5.6.1.
Treatment with sulphuric acid Spray sulphuric acid (3.13) onto the
chromatogram obtained in 5.4. The fluorescence of the aflatoxin B 1 spots must turn
from blue to yellow under UV irradiation.
5.6.2.
Two-dimensional chromatography involving the formation of aflatoxin
B 1 - hemiacetal (aflatoxin B 2a )
NB: The operations described below must be carried out following carefully the
diagram in figure 3.
5.6.2.1.
Application of the solutions
Score two straight lines on the plate (4.8) parallel to two contiguous sides (6 cm in
from each side) to limit migration of the solvent fronts. Spot the following solutions
on the plate using capillary pipettes or microsyringes
-
on point A: a volume of purified extract of the sample, obtained in 5.3,
containing about 2ꞏ5 nm of aflatoxin B 1 ;
-
on points B and C: 25 µl of the standard solution (3.16).
5.6.2.2.
Development
Develop the chromatogram indirection I, in the dark, using the developing solvent
(3.18.1) (1 cm layer in an unsaturated tank) until the solvent front reaches the
solvent limit line.
Remove the plate f rom the tank and allow to dry in the dark at ambient
temperature for five minutes. Then spray hydrochloric acid (3.12) along a band 2ꞏ5
cm high, covering points A and B (indicated by the hatched area in figure 3) until it
darkens, protecting the rest of the plate with a glass sheet. Allow to react for 10
minutes in the dark and dry with a stream of air at ambient temperature.
Next, develop the chromatogram indirection II, in the dark, using the developing
solvent (3.18.1) (1 cm layer in an unsaturated tank) until the solvent front reaches
the solvent limit line. Remove the plate from the tank and allow to dry at ambient
temperature.
5.6.2.3. Interpretation of the chromatogram Examine the chromatogram under
UV light (4.9) and check for the following features.
(a) Appearance of a blue fluorescent spot of aflatoxin B 1 originating from
the standard solution applied at C (migration in the direction I).
(b) Appearance of a blue fluorescent spot of unreacted (with the
hydrochloric acid) aflatoxin B 1 and a more intense blue fluorescent spot
of aflatoxin B 1 - hemiacetal, both originating from the standard solution
applied at B (migration in direction II).
(c) Appearance of spots matching those described in (b), originating from
the sample extract applied at A. The position of these spots is defined
first by the migration distance of the aflatoxin B 1 from point A in
direction I (the same as that traveled by the standard applied at C), and
then by the migration distances from there in direction II of the
aflatoxin B 1 - hemiacetal (same as those travelled by the standard
applied at B). The fluorescence intensities of hemiacetal spots
originating from the extract and from the standard applied at B should
match.
Calculation of the results
6.1.
From the visual measurements
The content in micrograms of aflatoxin B 1 per kg of sample (ppb) is given by the
formula
W • X
in which
Y and X are respectively the volumes in microlitres of the standard solution of
aflatoxin B 1 (3.16) and of the extract having a similar intensity of fluorescence;
S = concentration in micrograms of aflatoxin B 1 per ml in the standard solution
(3.16);
V = final volume of the extract in microlitres, allowing for any dilution that was
necessary;
W = weight in grammes of the sample corresponding to the volume of extract
subjected to column clean-up.
6.2.
From the fluorodensitometric measurements
The content in micrograms of aflatoxin B 1 per kg of sample is given by the
formula
S • V
W • Y
in which
Y = volume in microlitres of the extract spotted on the plate (10 or 20 µl);
S = quantity in nanograms of aflatoxin B 1 in the extract spot (proportional to the
value of Y taken), deduced from the measurements;
V = final volume of the extract in microlitres, allowing for any dilution that was
necessary;
W = weight in grammes of the sample corresponding to the volume of extract
subjected to column clean-up.
Preparation and testing of the standard solution (3.16)
7.1.
Determination of the concentration of aflatoxin B 1
Prepare a standard solution of aflatoxin B 1 in the chloroform (3.2) or the benzene/
acetonitrile mixture (3.6) with a concentration of 8 to 10 µg/ml. Determine the
absorption spectrum between 330 and 370 nm with the aid of the spectrophotometer
(4.11).
Measure the optical density (A) at 363 nm in the case of the chloroform solution[
or at 348 nm in the case of the solution in the benzene/acetonitrile mixture.
Calculate the concentration in micrograms of aflatoxin B 1 per ml of solution from
the formulae below
312 • A • 1000
for the chloroform solution;
20600
312 • A • 1000
for the solution in the benzene/acetonitrile mixture.
19800
Dilute as appropriate, away from day light, to obtain a working standard solution
with a concentration of aflatoxin B 1 of about 0ꞏ1 µg/ml. If kept in a refrigerator at
4ºC, this solution is stable for two weeks.
7.2.
Testing of chromatographic purity
Spot on a plate (4.8) 5 µl of the standard solution of aflatoxin B 1 containing 8 to
10 µg/ml (7.1). Develop the chromatogram as indicated in 5.4. In UV light the
chromatogram should show only one spot and no fluorescence must be perceptible in
the original deposit zone.
Repeatability
The difference between the results of two parallel determinations carried out on
the same sample by the same analyst should not exceed
-
25% related to the highest result for contents of aflatoxin B 1 from 10
and up to 20 µg/kg;
-
5 µg, in absolute value, for contents greater than 20 and up to 50 µg/kg;
-
10% related to the highest value for contents above 50 µg/kg.
Reproducibility
See under ‘Observations’, Part C, point 2.
B.
DETERMINATION OF AFLATOXIN B 1 . HIGH PERFORMANCE LIQUID
CHROMATOGRAPHIC METHOD
1. Purpose and scope
This method is for the determination of aflatoxin B 1 in animal feedingstuffs
including those containing citrus pulp. The lower limit of determination is 0,001 mg/
kg (1 ppb).
2. Principle
The sample is extracted with chloroform. The extract is filtered and an aliquot
portionis purified on a Florisil cartridge followed by a C 18 cartridge. The final
separation and determination is achieved by high performance liquid
chromatography (HPLC) using a reversed phase C 18 column, followed by post-
column derivatization with iodine in water, and fluorescence detection.
Note: mycotoxins are extremely toxic substances. Manipulations should be
performed in a designated fume cupboard. Special precautions should be taken when
toxins are in a dry form because of their electrostatic nature and resulting tendency
to disperse in working areas.
3. Reagents
3.1.
Chloroform, stabilized with 0,5 to 1,0% of ethanol, by mass. See
observation10.2.
3.2.
Methanol, HPLC grade for preatation of 3.6.
3.3.
Acetone.
3.4.
Acetonitril, HPLC grade.
3.5.
Eluting solvents{ Prepare one day before use, or remove air in the
solvents ultrasonically.
3.5.1.
Mixture of acetone (3.3) and water, 98 + 2 (v/v).
3.5.2.
Mixture of water and methanol (3.2), 80 + 20 (v/v).
3.5.3.
Mixture of water and acetone (3.3), 85 + 15 (v/v).
3.6.
Mobile phase for HPLC
Mixture of water, methanol (3.2) and acetonitril (3.4), 130 + 70 + 40 (v+v+v).
NB: The composition of the mobile phase solvent may need to be adjusted,
depending on the characteristics of the HPLC column used.
3.7.
Saturated iodine solution: add 2 g of iodine to 400 ml of water. Mix for
at least 90 min and filter through a membrane filter (4.15). Protect the saturated
solution from light to prevent photo degradation.
3.8.
Acid washed Celite 545, or equivalent.
3.9.
Florisil cartridge (Waters SEP-PAK), or equivalent.
3.10.
C 18 cartridge (Waters SEP-PAK), or equivalent.
3.11.
Inert gas e.g. nitrogen.
3.12.
Aflatoxin B 1 standard solution in chloroform, concentration 10 µg/ml.
Check the concentration of the solution as follows: determine the absorption
spectrum of the solution between 330 and 370 nm by means of the
spectrophotometer (4.23). Measure the absorbance (A) at the maximum near 363 nm.
Calculate the concentration of aflatoxin B 1 in micrograms per millilitre of solution
from the formula
Concentration (èmg/ml) = 312 x A x 1000 = 13,991 x A
22 300
3.12.1.
Aflatoxine B 1 stock standard solution in chloroform.
Transfer quantitatively 2,5 ml of the aflatoxin B 1 standard solution (3.12) to a 50
ml volumetric flask and adjust to the mark with chloroform (3.1). Store this solution
in a cool place (4ºC) in the dark, well sealed and wrapped in aluminium foil.
3.13.
Aflatoxin B 1 calibraltion solutions HPLC.
NB: Use alcid-washed glassware for preparation of these solutions (see 4,
Apparatus).
3.13.1.
Calibration solution 4 ng/ml.
Allow the volumetric flask with stock standard solution (3.12.1) to warm up to
room temperature in the aluminium foil (a few hours). Transfer 400 µl of the stock
standard solution (200 ng aflatoxin B 1 ) into a 50 ml volumetric flask, and evaporate
the solution to dryness in a current of inet gas (3.11).
Dissolve the residue obtained in approximately 20 ml of water/acetone mixture
(3.5.3), make up to the mark with the water/acetone mixture and mix well.
3.13.2.
Calibrationsolution 3 ng/ml.
Transfer quantitatively 7,5 ml of the calibration solution (3.13.1) into a 10 ml
volumetric flask, make up to the mark with the water/acetone mixture (3.5.3), and
mix well.
3.13.3.
Calibration solution, 2 ng]/l.
Transfer quantitatively 25 ml of the calibration solution (3.13.1) to a 50 ml
volumetric flask, make up to the mark with the water/acetone mixture (3.5.3) and
mix well.
This solution is also referred to as the reference standard, to be used for repetitive
injection during HPLC (5.5).
3.13.4.
Calibration solution 1 ng/ml.
Transfer quantitatively 2,5 ml of the calibration solution (3.13.1) to a 10 ml
volumetric flask, make up to the mark with the water/acetone mixture (3.5.3) and
mix well.
3.14.
Ampoule containing a mixture of aflatoxins B 1 , B 2 , G 1 and G 2
concentrations approximately 1, 0,5, 1 and 0,5 µg/ml respectively, in 1 ml
chloroform.
3.14.1.
Chromatographic test solution.
Transfer the content of the ampoule (3.14) into a glass-stoppered test-tube or
screw-capped vial. Transfer 40 µl of this solution into a glass-stoppered test tube
(acid-rinsed) (4.22). Evaporate the chloroform in a stream of inert gas (3.11) and
redissolve into 10 ml of the water/acetone mixture (3.5.3).
3.15.
Reagents for confirmatory test (6).
3.15.1.
Sodium chloride saturated solution.
3.15.2.
Sodium sulphate, anhydrous, granular.
4. Apparatus
Caution: Use of non acid-washed glassware for aqueous aflatoxin solutions may
cause losses. Particular care should be taken with new glassware and disposable
glassware such as autosampler vials and Pasteur pipettes. Therefore laboratory
glassware coming into contact with aqueous solutions of aflatoxins should be soaked
in dilute acid (e.g. sulfuric acid = 2 mol/l) for several hours, then rinsed well with
distilled water to remove all traces of acid (e.g. three times, check with pH-paper). In
practice, this treatment is necessary for the round bottomed flask (4.4), the
volumetric flasks, measuring cylinders, vials or tubes used for calibration solutions
and final extracts (particularly vials for autosamplers), and Pasteur pipettes, if these
are used to transfer calibration solutions or extracts.
4.1.
Grinder-mixer.
4.2.
Sieve of aperture size 1,0 mm, (ISO R 565).
4.3.
Mechanical shaker.
4.4.
Rotary vacuum evaporator, equipped with a 150 to 250 ml round
bottomed flask.
4.5.
High performance liquid chromatograph, injector with a loop suitable
for the injection of 250 ml. See the manufacturers instructions for partial or complete
loop filling.
METHODS OF ANALYSIS FOR THE
OFFICIAL CONTROL OF FEEDINGSTUFFS
HPLC analytical column: 3 µm or 5 µm C 18 packing.
Pulse-free pump for delivery of the iodine post-column reagent.
Valco zero dead volume Tee, stainless steel (1/16" × 0,75 mm).
Spiral reaction coil[ Teflon or stainless steel. Dimensions of 3 000 × 0,5
mm to 5 000 × 0,5 mm have been found to be appropriate in combination with 5 µm
or 3µm HPLC columns.
Thermostatically controlled water-bath adjusted to 60ºC, capable of
temperature regulation to better than 0,1ºC.
Fluorescence detector, with excitation at 365 nm and emission at 435 nm
wavelengths. (For filter instrument: emission wavelength : 400 nm). Detection of at
least 0,05 ng aflatoxin B 1 shall be possible. Some back pressure may be advisable
(e.g. restrictor, Teflon or stainless steel coil connected to the outlet of the detector),
to suppress air bubbles in the flow-cell.
Strip chart recorder.
Electronic integrator (optional).
Fluted filter paper diameter: 24 cm, Macherey-Nagel 617¼ or
equivalent.
Membrane filter with a pore size of 0,45 µm, Millipore HAWP 04700 or
equivalent.
500 ml glass stoppered conical flask.
Glass column (internal diameter
approximately
cm,
length
approximately 30 cm) equipped with a Luer tip.
Luer chloroform-resistant stopcock (e.g. Bio-rad 7328017, Analytichem
A1 6078, J.T. Baker 4514 or equivalent).
Chemically resistant syringe, 10 ml Luer connector.
Syringe suitable for HPLC injection of 250 µl (see 4.5).
100 µl microsyringe for preparation of calibration solutions (check that
the accuracy is within 2% by weighing).
10 ml glass stoppered calibrated tubes.
Spectrophotometer, suitable for making measurements in the UV region
of the spectrum.
Equipment for confirmatory test (6).
Acid-rinsed 100 ml separating funnel with Teflon stopcock.
Heating block, 40 to 50ºC.
5. Procedure
Preparation of the sample.
Grind the sample so that it passes through the sieve (4.2).
Test portion.
Weigh 50 g of the prepared test sample into the conical flask (4.16).
Extraction
Add 25 g of Celite (3.8), 250 ml of chloroform (3.1) and 25 ml of water to the test
portion (5.2). Stopper the flask, and shake for 30 minutes on a mechanical shaker
(4.3). Filter through a fluted filter paper (4.14). Collect 50 ml of the filtrate. If
necessary, take an aliquot of the filtrate and dilute to 50 ml with chloroform so that
the concentration of aflatoxin B 1 is not greater than 4 ng/ml.
5.4.
Clean-up (the procedure should be carried out without significant
interruptions).
Caution
-
protect the laboratory, where the analyses are done, adequately from
daylight. This can be achieved effectively by using
(i)
UV absorbing foil on the windows in combination with subdued
light (no direct sunlight);
(ii) Curtains or blinds in combination with artificial light (fluorescent
tubes are acceptable);
-
Aflatoxin containing solutions must be protected from light as much as
possible (keep in the dark, use aluminium foil).
5.4.1.
Florisil SEP-PAK purification
5.4.1.1.
Preparation of the column-cartridge assembly
Attach a stopcock (4.18) to the shorter stem of a Florisil cartridge (3.9) (see figure
1). Wash the cartridge and remove aid by taking 10 ml chloroform (3.1) and passing
8 ml via the stopcock rapidly through the cartridge using a syringe (4.19). Attach the
longer stem of the cartridge to a glass column (4.17) and pass the remaining 2 ml
chloroform through the cartridge into the column. Close the stopcock. Remove the
syringe.
5.4.1.2.
Purification
Add the filtrate collected in 5.3 to the column-cartridge assembly and drain by
gravity. Rinse with 5 ml of chloroform (3.1), followed by 20 ml of methanol (3.2).
Discard the eluates. During these operations, ensure that the column cartridge
assembly does not run dry.
Elute aflatoxin B 1 with 40 ml of the acetone-water mixture (3.5.1) and collect the
whole of the eluate in the round bottomed flask of the rotary evaporator (4.4).
Concentrate the eluate on the rotary evaporator at 40ºC to 50ºC until no more
acetone is distilled.
(NB: approximately 0,5 ml of liquid remains in the flask at this point. Experiments
have shown that further evaporation is not harmful and that when 0,5 ml of liquid
remains, there is then no significant amount of acetone. Residues of acetone might
lead to losses of aflatoxin B 1 on the C 18 cartridge).
Add 1 ml of methanol (3.2), swirl the flask to dissolve aflatoxin B 1 on the sides of
the flask, add 4 ml water, and mix. Disconnect and discard the cartridge. Rinse the
glass column with water and retain for the C 18 purification step.
5.4.2.
C 18 SEP-PAK purification
5.4.2.1.
Preparation of the column-cartridge assembly.
Attach a stopcock (4.18) to the shorter stem of a C 18 -cartridge (3.10) (see figure
1). Prime the cartridge and remove any air by passing 10 ml methanol (3.2) via the
stopcock rapidly through the cartridge with a syringe (4.19) (Air bubbles in the
cartridge are visible as light spots on the otherwise greyish background).
Take 10 ml water, and pass 8 ml through the cartridge (Avoid introduction of air
into the cartridge, when switching from methanol to water). Attach the longer stem
of the cartridge to a glass column (4.17) and pass the remaining 2 ml water through
the cartridge in the column. Close the stopcock. Remove the syringe.
5.4.2.2.
Purification
Transfer the extract collected in 5.4.1.2 quantitatively to the glass column (4.17),
rinsing the flask twice with 5 ml water/methanol mixture (3.5.2) and drain by
gravity. During these operations, ensure that the column-cartridge assembly does not
run dry. (When air bubbles develop in the constriction near the cartridge, stop the
flow and tap the top of the glass column, to remove the air bubbles. Then continue).
Elute with 25 ml water/methanol mixture. Discard the eluate. Elute the aflatoxin B 1
with 50 ml water/acetone mixture (3.5.3), and collect the whole of the eluate in a 50
ml volumetric flask. Make up to the mark with water and mix: the resulting test
solution is used for chromatography (5.5).
Caution: Filtration of the final extract prior to HPLC is normally not necessary. If
considered necessary, cellulose filters are not to be used, because they may lead to
losses of aflatoxin B 1 . Teflon filters are acceptable.
5.5.
High performance liquid chromatography
(See Figure 2 for setting-up of the equipment). Allow sufficient time for
conditioning and stabilizing the instruments.
Note 1
The flow-rates given for the mobile phase and the post-column reagent are
indicative only. They may need to be adjusted depending on the characteristics of the
HPLC column.
Note 2
The detector response to aflatoxin B 1 depends on the temperature, therefore
compensation should be made for drift (see Figure 3). By injecting a fixed amoung
of aflatoxin B 1 reference standard (3.13.3) at regular intervals (i.e. every third
injection), the aflatoxin B 1 peak values between these reference standards can be
corrected using the mean response, provided that the difference between responses
of consecutive reference standards is very small (< 10%). Therefore injections must
be made without interruptions. If interruption is necessary, the last injection before
interruption and the first injection after interruption must be the reference standard
(3.13.3). Because the calibration curve is linear and passes through the origin, the
amounts of aflatoxin B 1 in the sample extracts are determined directly by reference
to the adjacent standards.
5.5.1.
HPLC pump settings
Set the HPLC pump (4.5) to give a flow of 0,5 or 0,3 ml/min for a 5 µm or a 3 µm
HPLC column (4.6) respectively using the mobile phase (3.6).
5.5.2.
Post-column pump settings
Set the pump (4.7) to give a flow of 0,2 to 0,4 ml/min of the iodine-saturated water
solution (3.7). As a rough guide: Flows of approximately 0,4 or 0,2 ml/min are
advisable in combination with flows of 0,5 and 0,3 ml/min of the mobile phase (3.6)
respectively.
5.5.3.
Fluorescence detector
Set the fluorescence detector (4,11) to exc. = 365 nm and em = 435 nm (filter
instrument; > 400 nm). Adjust the detector attenuator to obtain approximately 80%
full scale deflection of the recorder pen for 1 ng of aflatoxin B 1 .
5.5.4.
Injector
For all solutions, inject 250 µl amounts following the instructions of the
manufacturer of the injector.
5.5.5.
Check of chromatographic separation
Inject the chromatographic test solution (3.14.1). Valleys should be less than 5%
of the sum of peak heights of the adjacent peaks.
5.5.6.
Check of the stability of the system
Before each series of analyses, respectively inject the reference standard (3.13.3),
until stable peak areas are achieved (NB Peak responses for aflatoxin B 1 between
consecutive injections should not differ by more than 6%). Proceed without delay
with the check of linearity (5.5.7).
5.5.7.
Check of linearity
Inject the aflatoxin B 1 calibration solutions (3.13.1 to 3.13.4). Every third
injection use the reference standard (3.13.3), for correction of drift in response (NB
Peak responses for this reference standard must not differ by more than 10% in 90
minutes). Correct for drift according to the formula in 7. The calibration graph
should be linear and pass through the origin, within twice standard error of Y-
estimate. Values found must not differ by more than 3% from the nominal values. If
these requirements are fulfilled, continue without delay. If not, identify and correct
the sources of the problem before continuing.
5.5.8.
Injection of sample extracts
Inject the purified sample extracts (5.4.2.2). After every two sample extracts
repeat the injection of the reference standard (3.13.3) according to the following
sequence: reference standard, extract, extract, reference standard, extract, extract,
reference standard etc.
6. Confirmatory test
6.1.
Further treatment of the extract (5.4.2.2)
Add 5 ml sodium chloride solution (3.15.1) to the final extract obtained at 5.4.2.2.
Extract three times each with 2 ml chloroform (3.1) for one minute, in the separating
funnel (4.24.1). Pour the combined chloroform extracts over approximately 1 g
sodium sulphate (3.15.2) into a 10 ml test tube. A small funnel (diameter: 4 cm) can
be used with a piece of cottonwool in the constriction, covered with a approximately
1 g sodium sulphate.
Wash the sodium sulphate layer with a few ml of chloroform and collect the
washing in the same test tube. Evaporate the chloroform extract to dryness in the
same test-tube using the heating block (4.24.2) and redissolve in 1 ml of chloroform.
6.2.
Preparation of derivative and thin layer chromatography
See Annex to European Council Directive 76/372/EEC method A, point 5.6.2.
7. Calculation of results
Calculate the aflatoxin B 1 content (µm/kg) present in the sample, using the
formula
aflatoxin B 1 content in èmg/kg =
m x V e x t
V m x M x
V f
V c
where
m = amount of aflatoxin B 1 in ng represented by the B 1 peak of the sample,
calculated as follows
P(sample)
m -
x 2 r(st)
P(st 1 ) + P(st 2 )
P(sample) = peak area of aflatoxin B 1 for the sample
P(st 1 ) = peak area of aflatoxin B 1 resulting from the preceeding injection of
reference standard (3.13.3)
P(st 2 ) = peak area of aflatoxin B 1 resulting from the following injection of
reference standard (3.13.3)
r(st) = injected amount of aflatoxin B 1 in the reference standard (3.13.3) in ng
V m = volume of the injected sample extract in ml
V e x t = final volume of sample extract in ml, allowing for any dilution that was
made (5.3)
M = mass of sample in g
V f = volume of filtrate transferred to Florisil cartridge (5.4.1.2) in ml
V c = volume of chloroform, used for the extraction of the sample in ml
If the procedure is followed as in this protocol, the formula reduces to
aflatoxin B 1 content in µg/kg = 20 × m.
7.1.
Calculations of the results may also be done by peak height
measurement.
8. Repeatability
see under 10.1
9. Reproducibility
see under 10.1
Observations
10.1.
Precision
A collaborative study * , carried out at the international level on mixed feeding
stuffs gave the results for repeatability and reproducibility indicated in Table 1. The
term repeatability (r) used here is defined as the largest ratio which is not significant
at the 95% probability level for comparison of two readings of the same sample in
the same laboratory under similar conditions. The term reproducibility (R) is
similarly defined for comparing two different laboratories. In accordance to ISO
3534 - 1977, 2.35 † and European Union Commission Decision 89/610/EEC r and R
are also given in Table 1 in terms of coefficients of variation.
Table 1
Repeatability (r) and reproducibility (R) expressed as ratios
and corresponding coefficients of variation
(15 laboratories)
*Egmond, H.P. van, Heisterkamp, S.H. and Paulsch, W.E. (1991). Food Additives and Contaminants 8, 17-
†ISO 3534-1977.
Level
r
R
CV r (*)
CV R
(µg/kg)
(%)
(%)
8 & 14
1,4
1,7
(*) CV = coefficient of variation
10.2.
Stabilization of chloroform (3.1)
The adsorption characteristics of the florisil cartridge may be changed if
stabilizers other than ethanol are used. This should be verified in accordance with
10.3 when the chloroform described is not available.
10.3.
Accuracy
The correct applications of the method shall be verified by making replicate
measurements on certified reference materials. If these are not available, the
performance of the method should be verified by recovery experiments made on the
fortified blank samples. The deviation of the mean from the actual value, expressed
as a percentage of the actual value, shall not lie outside the limits -20 to +10%.
Figure 1: Column-cartridge assembly
Figure 2: Flow diagram of the LC system with iodine post-column derivatization
Figure 3: Compensation for drift in aflatoxin B 1 response by injecting reference
standard (3.13.3) at regular intervals
C.
OBSERVATIONS CONCERNING METHODS A AND B
1. Defatting
Samples containing more than 5% fats must be defatted with light petroleum (bp
40 to 60 degrees C) after the preparations indicated in 5.1.
In such cases, the analytical results must be expressed in terms of the weight of the
non-defatted sample.
2. Reproducibility of the results for Method A
The reproducibility of the results, i.e. the variation between the results obtained by
two or more laboratories on the same sample has been estimated at
± 50% of the mean value for mean values of aflatoxin B, from 10 and up
to 20 mg/kg;
± 10 mg/kg of the mean value for mean values greater than 20 and up to
50 mg/kg;
± 20% of the mean value for mean values above 50 mg/kg.
Appendix to Annex
Figure 1
Figure 2
Figure 3