SAMPLING METHODS AND METHODS OF ANALYSIS FOR THE OFFICIAL CONTROL OF DIOXINS AND THE DETERMINATION OF
Table of Provisions (11)
Statutory Text (11 Articles)
DETERMINATION OF DIOXIN-LIKE PCBs IN FOODSTUFFS
SUBSIDIARY LEGISLATION 437.75
SAMPLING METHODS AND METHODS
OF ANALYSIS FOR THE OFFICIAL CONTROL
OF DIOXINS AND THE DETERMINATION OF
DIOXIN-LIKE PCBs IN FOODSTUFFS RULES *
5th July, 2005
LEGAL NOTICE 241 of 2005.
(1) The title of these rules is the Sampling Methods and
Methods of Analysis for the Official Control of Dioxins and the
Determination of Dioxin-like PCBs in Foodstuffs Rules.
(2) The scope of these rules is to implement the rules found
under European Union Council Directive 2002/69/EC on the
sampling methods and the methods of analysis for the official
control of dioxins and the determination of dioxin-like PCBs in
foodstuffs.
METHODS OF SAMPLING FOR OFFICIAL CONTROL OF THE LEVELS OF
DIOXINS (PCDD/PCDF) AND THE DETERMINATION OF DIOXIN-LIKE PCBs
IN CERTAIN FOODSTUFFS
1. Purpose and scope
Samples intended for the official control of the levels of dioxins (PCDD/PCDF)
content, as well for the determination of the content of dioxin-like PCBs in
foodstuffs shall be taken according to the methods described below. Aggregate
samples thus obtained shall be considered as representative of the lots or sublots
from which they are taken. Compliance with maximum levels laid down in
Commission Regulation (EC) No 466/2001 setting maximum levels for certain
contaminants in foodstuffs shall be established on the basis of the levels determined
in the laboratory samples.
Congener
TEF value
Congener
TEF value
Dibenzo-p-dioxins (PCDDs)
‘Dioxin-like’ PCBsNon-ortho PCBs +
Mono-ortho PCBs
2,3,7,8-TCDD
Non-ortho PCBs
1,2,3,7,8-PeCDD
PCB 77
0,0001
1,2,3,4,7,8-HxCDD
0,1
PCB 81
0,0001
1,2,3,6,7,8-HxCDD
0,1
PCB 126
0,1
1,2,3,7,8,9-HxCDD
0,1
PCB 169
0,01
1,2,3,4,6,7,8-HpCDD 0,01
OCDD
0,0001
Dibenzofurans (PCDFs)
Mono-ortho PCBs
2,3,7,8-TCDF
0,1
PCB 105
0,0001
1,2,3,7,8-PeCDF
0,05
PCB 114
0,0005
2,3,4,7,8-PeCDF
0,5
PCB 118
0,0001
1,2,3,4,7,8-HxCDF
0,1
PCB 123
0,0001
1,2,3,6,7,8-HxCDF
0,1
PCB 156
0,0005
1,2,3,7,8,9-HxCDF
0,1
PCB 157
0,0005
2,3,4,6,7,8-HxCDF
0,1
PCB 167
0,00001
1,2,3,4,6,7,8-HpCDF 0,01
PCB 189
0,0001
1,2,3,4, 7,8,9-HpCDF 0,0001
Abbreviations used: T = tetra; Pe = penta; Hx = hexa; Hp = hepta; O = octa; CDD
= chlorodibenzodioxin; CDF = chlorodibenzofuran; CB = chlorobiphenyl.
2. General provisions
2.1. Personnel
Sampling shall be performed by an authorised qualified person as specified by the
Veterinary Services.
2.2. Material to be sampled
Each lot, which is to be examined, must be sampled separately.
2.3. Precautions to be taken
In the course of sampling and preparation of laboratory samples precautions must
DETERMINATION OF DIOXIN-LIKE PCBs IN FOODSTUFFS
be taken to avoid any changes, which would affect the content of dioxins and dioxin-
like PCBs, adversely affect the analytical determination or make the aggregate
samples unrepresentative.
2.4. Incremental samples
As far as practical incremental samples shall be taken at various places distributed
throughout the lot or sublot. Departure from this procedure must be recorded in the
record provided for under 2.8.
2.5. Preparation of the aggregate sample
The aggregate sample is made up by uniting all incremental samples. It shall be at
least 1 kg unless not practical, e.g. when a single package has been sampled.
2.6. Subdivision of aggregate sample in laboratory samples for enforcement,
defence and referee purposes The laboratory samples for enforcement, trade
(defence) and referee purposes shall be taken from the homogenized aggregate
sample unless this conflicts with Member States' regulations on sampling. The size
of the laboratory samples for enforcement shall be sufficient to allow at least for
duplicate analyses.
2.7. Packaging and transmission of aggregate and laboratory samples
Each aggregate and laboratory sample shall be placed in a clean, inert container
offering adequate protection from contamination, from loss of analytes by adsorption
to the internal wall of the container and against damage in transit. All necessary
precautions shall be taken to avoid change of composition of the aggregate and
laboratory samples, which might arise during transportation or storage.
2.8. Sealing and labelling of aggregate and laboratory samples
Each sample taken for official use shall be sealed at the place of sampling and
identified following the Veterinary Services’ regulations. A record must be kept of
each sampling, permitting each lot to be identified unambiguously and giving the
date and place of sampling together with any additional information likely to be of
assistance to the analyst.
3. Sampling plans
T h e s a m p l i ng m e t h o d ap p l ie d s h a ll e n s u r e t ha t t h e a g g r e g a t e s a mp le is
representative for the lot that is to be controlled.
Number of incremental samples
In the case of milk and oils, for which a homogeneous distribution of the
contaminants in question can be assumed within a given lot, it is sufficient to take
three incremental samples per lot which forms the aggregate sample. Reference to
the lot number shall be given. For other products, the minimum number of
incremental samples to be taken from the lot shall be as given in Table 1.
The aggregate sample uniting all incremental samples shall be at least 1 kg (see
point 2.5). The incremental samples shall be of similar weight. The weight of an
incremental sample should be at least 100 grams. The weight of the incremental
sample is dependent on the size of the particles in the lot. Departure from this
procedure must be recorded in the record provided for under 3.8. In accordance with
the provisions of Commission Decision 97/747/EC of 27 October 1997 fixing the
levels and frequencies of sampling provided for by Council Directive 96/23/EC for
the monitoring of certain substances and residues thereof in certain animal products,
the sample size for hen eggs is at least 12 eggs (for bulk lots as well for lots
DETERMINATION OF DIOXIN-LIKE PCBs IN FOODSTUFFS
consisting of individual packages, Tables 1 and 2).
TABLE 1
Minimum number of incremental samples to be taken from the lot
Weight of lot (in kg)
Minimum number of incremental samples
to be taken
< 50
50 to 500
> 500
If the lot consists of individual packages, then the number of packages, which
shall be taken to form the aggregate sample, is given in Table 2.
TABLE 2
Number of packages (incremental samples) which shall be taken to form the
aggregate sample if the lot consists of individual packages
Number of packages or units in the lot Number of packages or units to be taken
1 to 25
1 package or unit
26 to 100
about 5%, at least 2 packages or units
> 100
about 5%, at maximum 10 packages or units
For the purposes of these rules, and unless context
otherwise requires -
"aggregate sample" means the combined total of all the
incremental samples taken from the lot or sublot;
"the Commission" means the European Commission;
"the Community" means the European Community as established
under the Treaty establishing the European Community;
"the competent authority" means the Veterinary Services within
the territory of Malta as provided under article 2 of the Veterinary
Services Act;
"incremental sample" means a quantity of material taken from a
single place in the lot or sublot;
"laboratory sample" means a representative part/quantity of the
aggregate sample intended for the laboratory;
"lot" means an identifiable quantity of food delivered at one time
and determined by the official to have common characteristics,
such as origin, variety, type of packing, packer, consignor or
markings. In the case of fish and fishery products, also the size of
fish shall be comparable;
"Member State" means a State which is a Member within the
European Community;
"sublot" means the designated part of a large lot in order to apply
the sampling method on that designated part. Each sublot must be
physically separated and identifiable;
*These rules have been repealed by Legal Notice 94 of 2025.
DETERMINATION OF DIOXIN-LIKE PCBs IN FOODSTUFFS
"third country" means a State which is not a Member within the
European Community;
"Veterinary Services" means the competent authority within the
territory of Malta as established under article 2 of the Veterinary
Services Act<
SAMPLE PREPARATION AND REQUIREMENTS FOR METHODS OF
ANALYSIS USED IN OFFICIAL CONTROL OF THE LEVELS OF DIOXINS
(PCDD/PCDF) AND THE DETERMINATION OF DIOXIN-LIKE PCBs IN
CERTAIN FOODSTUFFS
1. Objective and field of application
These requirements should be applied where foodstuffs are analysed for the
official control of the levels of dioxins (polychlorinated dibenzo-p-dioxins (PCDD)
and polychlorinated dibenzofurans (PCDF)) and the determination of dioxin-like
PCBs.
Monitoring for the presence of dioxins in foodstuffs can be performed by a
strategy involving a screening method in order to select those samples with levels of
dioxins and dioxin-like PCBs that are less than 30-40% below or exceed the level of
interest. The concentration of dioxins in those samples with significant levels needs
to be determined/confirmed by a confirmatory method.
Screening methods are methods that are used to detect the presence of dioxins and
dioxin-like PCBs at the level of interest. These methods have a capacity for a high
DETERMINATION OF DIOXIN-LIKE PCBs IN FOODSTUFFS
sample throughput and are used to sift large numbers of samples for potential
positives. They are specifically designed to avoid false negatives.
C o n f i r m a t o r y m e t h o d s a r e m e t h o d s t h a t p r o v i d e f u l l o r c om p l e m e n t a r y
information enabling the dioxins and dioxin-like PCBs to be identified and
quantified unequivocally at the level of interest.
2. Background
Because environmental and biological samples (including samples of foodstuffs)
in general contain complex mixtures of different dioxin congeners, the concept of
Toxic Equivalency Factors (TEFs) has been developed to facilitate risk assessment.
These TEFs have been established to express concentrations of mixtures of 2,3,7,8-
substituted PCDDs and PCDFs, and more recently, some non-ortho and mono-ortho
chlorine substituted PCBs which possesses dioxin-like activity in toxic equivalents
(TEQs) of 2,3,7,8-TCDD (see Annex 1).
The concentrations of the individual substances in a given sample are multiplied
by their respective TEF and subsequently summed to give the total concentration of
dioxin-like compounds expressed as TEQs.
The concept of ‘upperbound’ requires using the limit of quantification for the
contribution of each non-quantified congener to the TEQ.
The concept of ‘lowerbound’ requires using zero for the contribution of each non-
quantified congener to the TEQ.
The concept of ‘mediumbound’ requires using half of the limit of quantification
calculating the contribution of each non-quantified congener to the TEQ.
3. Quality assurance requirements to be complied with for sample preparation
Measures must be taken to avoid cross-contamination at each stage of
the sampling and analysis procedure.
The samples must be stored and transported in glass, aluminium,
polypropylene or polyethylene containers. Traces of paper dust must be
removed from the sample container. Glassware should be rinsed with
solvents previously controlled for the presence of dioxins.
The sample storage and transportation has to be performed in a way that
maintains the integrity of the foodstuff sample.
Insofar as relevant, finely grind and mix thoroughly each laboratory
sample using a process that has been demonstrated to achieve complete
homogenisation (e.g. ground to pass a 1 mm sieve); samples have to be
dried before grinding if moisture content is too high.
Perform a blank analysis by carrying out the entire analytical procedure
omitting only the sample.
Sample weight used for the extraction must be sufficient to fulfil the
requirements with respect to sensitivity.
There are many satisfactory specific sample preparation procedures,
which may be used for the products under consideration. The
procedures have to be validated according to internationally accepted
guidelines.
4. Requirementsfor laboratories
Laboratories shall demonstrate the performance of a method in the
DETERMINATION OF DIOXIN-LIKE PCBs IN FOODSTUFFS
range of the level of interest, e.g. 0,5 ×, 1 × and 2 × the level of interest
with an acceptable coefficient of variation for repeated analysis. For
details of acceptance criteria, see point 5.
Limit of quantification for a confirmatory method should be in the range
of about one fifth of the level of interest, to make sure that acceptable
coefficients of variations are met in the range of the level of interest.
Regular blank controls and spiking experiments or analysis of control
samples (preferably, if available, certified reference material) should be
performed as internal quality control measures.
Successful participation in interlaboratory studies that assess laboratory
proficiency is the best way to prove the competence in specific
analyses. However successful participation in interlaboratory studies
for, e.g. soil or sewage samples, does not necessarily prove the
competence also in the field of food or feedingstuff samples, which
present lower contamination levels. Therefore, the continuous
participation in interlaboratory studies for the determination of dioxins
and dioxin-like PCBs in the relevant feed/food matrices is mandatory.
In accordance with the provisions of Directive 93/99/EEC, laboratories
should be accredited by a recognised body operating in accordance with
ISO Guide 58 to ensure that they are applying analytical quality
assurance. Laboratories should be accredited following the ISO/IEC/
17025:1999 standard.
5. Requirementsto be met by analytical procedure for dioxinsand dioxin-like
Basic requirements for acceptance of analytical procedures
High sensitivity and low limits of detection. For PCDDs and PCDFs,
detectable quantities have to be in the pictogram TEQ (10-12 g) range
because of extreme toxicity of some of these compounds. PCBs are
known to occur at higher levels than the PCDDs and PCDFs. For most
PCB congeners sensitivity in the nanogram (10-9 g) range is already
sufficient. However, for the measurement of the more toxic dioxin-like
PCB congeners (in particular non-ortho substituted congeners), the
same sensitivity must be reached as for the PCDDs and PCDFs.
High selectivity (specificity). A distinction is required for PCDDs,
PCDFs and dioxin-like PCBs from a multitude of other, coextracted and
possibly interfering compounds present at concentrations up to several
orders of magnitude higher than those of the analytes of interest. For
gas chromatography/mass spectrometry (GC/MS) methods a
differentiation among various congeners is necessary, such as between
toxic (e.g. the seventeen 2,3,7,8-substituted PCDDs and PCDFs and
dioxin-like PCBs) and other congeners. Bioassays should be able to
determine TEQ values selectively as the sum of PCDDs, PCDFs and
dioxin-like PCBs.
High accuracy (trueness and precision). The determination should
provide a valid estimate of the true concentration in a sample. High
accuracy (accuracy of the measurement: the closeness of the agreement
between the result of a measurement with the true or assigned value of
the measurement) is necessary to avoid the rejection of a sample
analysis result on the basis of poor reliability of the estimate of TEQ.
Accuracy is expressed as trueness (difference between the mean value
DETERMINATION OF DIOXIN-LIKE PCBs IN FOODSTUFFS
measured for an analyte in a certified material and its certified value,
expressed as percentage of this value) and precision (precision is
usually calculated as a standard deviation including repeatability and
reproducibility, and indicates the closeness of agreement between the
results obtained by applying the experimental procedure several times
under prescribed conditions).
Screening methods can comprise bioassays and GC/MS methods; confirmatory
methods are high-resolution gas chromatography/high resolution mass spectrometry
(HRGC/HRMS) methods. Following criteria have to be complied with on total TEQ
False negative rate
< 1%
Trueness
– 20% to + 20%
< 30%
< 15%
Malta shall ensure that the sampling for the official control
of the levels of dioxins and furans and the determination of the
l e v e l s o f d i o x i n - l i k e P C B s i n f o o d s t u ff s i s c a r r i e d o u t i n
accordance with the methods described in Schedule I.
Malta shall ensure that sample preparation and methods of
analyses used for the official control of the levels of dioxins and
furans and the determination of the levels of dioxin-like PCBs in
foodstuffs comply with the criteria described in Schedule II.
DETERMINATION OF DIOXIN-LIKE PCBs IN FOODSTUFFS
Compliance of the lot or sublot with the specification
The control laboratory shall analyse the laboratory sample for enforcement in
duplicate analysis in case the obtained result of the first analysis is less than 20%
below or above the maximum level, and calculate the mean of the results. The lot is
accepted if the result of the first analysis is more than 20% below the maximum level
or, where duplicate analysis is necessary, if the mean conforms to the respective
maximum level as laid down in Regulation (EC) No 466/2001.
Specific requirements for GC/MS methods to be complied with for
screening or confirmatory purposes
Addition of 13C-labelled 2,3,7,8-chlorine substituted internal PCDD/F
standards (and of 13C-labelled internal dioxin-like PCB standards, if dioxin-like
PCBs have to be determined) must be carried out at the very beginning or start of the
analytical method e.g. prior to extraction in order to validate the analytical
procedure. At least one congener for each of t he t etra to octa- chlorinated
homologous groups for PCDD/F (and at least one congener for each of the
ho m o l o g o us g r ou p s f o r d i o xi n - l i k e P C B s , i f di o x i n - li k e P C B s h a ve t o b e
determined) must be added (alternatively, at least one congener for each mass
spectrometric selected ion recording function used for monitoring PCDD/F and
dioxin-like PCBs). There is a clear preference, certainly in case of confirmatory
methods, of using all 17 13C-labelled 2,3,7,8-substituted internal PCDD/F standards
and all 12 13C-labelled internal dioxin-like PCB standard (if dioxin-like PCBs have
to be determined).
Relative response factors should also be determined for those congeners for which
no 13C-labelled analogue is added by using appropriate calibration solutions.
For foodstuffs of plant origin and foodstuffs of animal origin containing
less than 10% fat, the addition of the internal standards is mandatory
prior to extraction. For foodstuffs of animal origin containing more than
10% fat, the internal standards can be added either before extraction or
after fat extraction. An appropriate validation of the extraction
efficiency should be carried out, depending on the stage at which
internal standards are introduced and on whether results are reported on
product or fat basis.
Prior to GC/MS analysis, 1 or 2 recovery (surrogate) standard(s) must be
Control of recovery is necessary. For confirmatory methods, the
recoveries of the individual internal standards should be in the range of
60% to 120%. Lower or higher recoveries for individual congeners, in
particular for some hepta- and octa- chlorinated dibenzodioxins and
dibenzofurans, are acceptable on the condition that their contribution to
the TEQ value does not exceed 10% of the total TEQ value (based on
PCDD/F only). For screening methods, the recoveries should be in the
DETERMINATION OF DIOXIN-LIKE PCBs IN FOODSTUFFS
range of 30% to 140%.
Separation of dioxins from interfering chlorinated compounds such as
PCBs and chlorinated diphenyl ethers should be carried out by suitable
chromatographic techniques (preferably with a florisil, alumina and/or
carbon column).
Gaschromatographic separation of isomers should be sufficient (< 25 %
peak to peak between 1,2,3,4,7,8-HxCDF and 1,2,3,6,7,8-HxCDF).
Determination should be performed according to EPA Method 1613
revision B: Tetra- through octa-chlorinated dioxins and furans by
isotope dilution HRGC/HRMS or another with equivalent performance
criteria.
The difference between upperbound level and lower bound level should not
exceed 20% for foodstuffs with a dioxin contamination of about 1 pg WHO-TEQ/g
fat (based on PCDD/PCDF only). For foodstuffs with a low fat content, the same
requirements for contamination levels of about 1 pg WHO-TEQ/g product have to be
applied. For lower contamination levels, for example 0,50 pg WHO-TEQ/g product,
the difference between upperbound and lowerbound level may be in the range of 25
Screening methodsof analysis
7.1. Introduction
Different analytical approaches can be performed using a screening method: a
pure screening approach and a quantitative approach.
Screening approach
The response of samples is compared to that of a reference sample at the level of
interest. Samples with a response less than the reference are declared negative, those
with a higher response are suspected positives.
Requirements
A blank and a reference sample(s) have to be included in each test
series, which is extracted and tested at the same time under identical
conditions. The reference sample must show a clearly elevated response
in comparison to a blank.
Extra reference samples 0,5 × and 2 × the level of interest should be
included to demonstrate the proper performance of the test in the range
of interest for the control of the level of interest.
When testing other matrices, the suitability of the reference sample(s) has to
be demonstrated, preferentially by including samples shown by HRGC/HRMS to
contain a TEQ level around that of the reference sample or else a blank spiked at this
Since no internal standards can be used in bioassays, tests on
repeatability are very important to obtain information on the standard
deviation within one test series. The coefficient of variation should be
below 30%.
For bioassays, the target compounds, possible interferences and
maximum tolerable blank levels should be defined.
Quantitative approach
The quantitative approach requires standard dilution series, duplicate or triplicate
DETERMINATION OF DIOXIN-LIKE PCBs IN FOODSTUFFS
clean up and measuring as well as blank and recovery controls. The result may be
expressed as TEQ, thereby assuming that the compounds responsible for the signal
correspond to the TEQ principle. This can be performed by using TCDD (or a
dioxin/furan standard mixture) to produce a calibration curve to calculate the TEQ
level in the extract and thus in the sample. This is subsequently corrected for the
TEQ level calculated for a blank sample (to account for impurities from solvents and
chemicals used), and a recovery (calculated from the TEQ level in a quality control
sample around the level of interest). It is essential to note that part of the apparent
recovery loss may be due to matrix effects and/or differences between the TEF
values in the bioassays and the official TEF values set by WHO.
7.2. Requirements for methods of analysis used for screening
GC/MS methods of analysis and bioassays may be used for screening.
For GC/MS methods the requirements as laid down in point 6 are to be
used. For cell based bioassays specific requirements are laid down in
point 7.3 and for kit-based bioassays in point 7.4.
Information on the number of false-positive and false-negative results
of a large set of samples below and above the maximum level or action
level is necessary, in comparison to the TEQ content as determined by a
confirmatory method of analysis. Actual false negative rates should be
under 1%. The rate of false positive samples should be low enough to
make the use of a screening tool advantageous.
Positive results have always to be confirmed by a confirmatory method of
analysis (HRGC/HRMS). In addition, samples from a wide TEQ-range should be
confirmed by HRGC/HRMS (approximately 2% to 10% of the negative samples).
Information on correspondence between bioassay and HRGC/HRMS results should
be made available.
7.3. Specific requirements for cell-based bioassays
When performing a bioassay, every test run requires a series of
reference concentrations of TCDD or a dioxin/furan mixture (full dose-
response curve with a R2 > 0,95). However, for screening purposes an
expanded low level curve for analysing low level samples could be
used.
A TCDD reference concentration (about 3 × limit of quantification) on a
quality control sheet should be used for the outcome of the bioassay
over a constant time period. An alternative could be the relative
response of a reference sample in comparison to the TCDD calibration
line since the response of the cells may depend on many factors.
Quality control (QC) charts for each type of reference material should
be recorded and checked to make sure the outcome is in accordance
with the stated guidelines.
In particular for quantitative calculations, the induction of the sample
dilution used must be within the linear portion of the response curve.
Samples above the linear portion of the response curve must be diluted
and re-tested. Therefore, at least three or more dilutions at one time are
recommended to be tested.
The percent standard deviation should not be above 15% in a triplicate
determination for each sample dilution and not above 30% between
three independent experiments.
DETERMINATION OF DIOXIN-LIKE PCBs IN FOODSTUFFS
-
The limit of detection may be set as 3 × the standard deviation of the solvent
blank or of the background response. Another approach is to apply a response that is
above the background (induction factor 5 × the solvent blank) calculated from the
calibration curve of the day. The limit of quantification may be set as 5 × to 6 × the
standard deviation of the solvent blank or of the background response or to apply a
response that is above the background (induction factor 10 × the solvent blank)
calculated from the calibration curve of the day.
7.4. Specific requirements for kit-based bioassays (1)
-
Manufacturer’s instructions for sample preparation and analyses have to
be followed.
-
Test kits should not be used after the expiration date.
-
Materials or components designed for use with other kits should not be
used.
-
Test kits should be kept within the specified range of storage
temperature and used at the specified operating temperature.
-
The limit of detection for immunoassays is determined as 3 × the
standard deviation, based on 10 replicate analysis of the blank, to be
divided by the slope value of the linear regression equation.
-
Reference standards should be used for tests at the laboratory to make
sure that the responsiveness to the standard is within an acceptable
range.
Reporting of the result
Insofar as the used analytical procedure makes it possible, the analytical results
should contain the levels of the individual PCDD/F and PCB congeners and be
reported as lowerbound, upperbound and mediumbound in order to include a
maximum of information in the reporting of the results and thereby enabling the
interpretation of the results according to specific requirements.
The report should also include the lipid content of the sample as well the method
used for lipid extraction.
The recoveries of the individual internal standards must be made available in case
the recoveries are outside the range mentioned in point 6, in case the maximum level
is exceeded and in other cases upon request.