SAMPLING METHODS AND METHODS OF ANALYSIS FOR THE OFFICIAL CONTROL OF THE LEVELS OF LEAD, CADMIUM, MERCURY
Table of Provisions (8)
Statutory Text (8 Articles)
CADMIUM, MERCURY AND 3-MCPD IN FOODSTUFFS
SUBSIDIARY LEGISLATION 437.66
SAMPLING METHODS AND METHODS
OF ANALYSIS FOR THE OFFICIAL CONTROL
OF THE LEVELS OF LEAD, CADMIUM, MERCURY
AND 3-MCPD IN FOODSTUFFS RULES
8th April, 2005
LEGAL NOTICE 98 of 2005.
(1) The title of these rules is the Sampling Methods and
Methods of Analysis for the Official Control of the Levels of Lead,
Cadmium, Mercury and 3-MCPD in Foodstuffs Rules.
(2) The scope of these rules is to implement the rules found
under European Union Council Directive 2001/22/EC on the
sampling methods and the methods of analysis for the official
control of the levels of lead, cadmium, mercury and 3-MCPD in
foodstuffs.
METHODS OF SAMPLING FOR OFFICAL CONTROL OF THE LEVELS OF
LEAD, CADMIUM, MERCURY AND 3-MCPD IN CERTAIN FOODSTUFFS
1. PURPOSE AND SCOPE
Samples intended for the official control of the levels of lead, cadmium, mercury
and 3-MCPD contents in foodstuffs shall be taken according to the methods
des c r i bed b e l ow. A gg re ga t e s a mp l e s t hus obtained shall be considered as
representative of the lots or sublots from which they are taken. Compliance with
maximum levels laid down in Regulation (EC) No 466/2001 shall be established on
the basis of the levels determined in the laboratory samples.
2. GENERAL PROVISIONS
2.1. Personnel
Sampling shall be performed by an authorised qualified person as specified by
Malta.
2.2. Material to be sampled
Each lot which is to be examined must be sampled separately.
2.3. Precautions to be taken
In the course of sampling and preparation of laboratory samples precautions must
be taken to avoid any changes which would affect the lead, cadmium, mercury and 3-
MCPD contents, adversely affect the analytical determination or make the aggregate
samples unrepresentative.
2.4. Incremental samples
As far as possible incremental samples shall be taken at various places distributed
throughout the lot or sublot. Departure from this procedure must be recorded in the
record provided for under 2.8.
2.5. Preparation of the aggregate sample
The aggregate sample is made up by uniting all incremental samples. It shall be at
least 1 kg unless not practical, e.g. when a single package has been sampled.
2.6. Subdivision of aggregate sample in laboratory samples for enforcement,
defence and referee purposes
The laboratory samples for enforcement, trade (defence) and referee purposes
shall be taken from the homogenised aggregate sample unless this conflicts with
Veterinary Services’ regulations on sampling. The size of the laboratory samples for
enforcement shall be sufficient to allow at least for duplicate analyses.
2.7. Packaging and transmission of aggregate and laboratory samples
Each aggregate and laboratory sample shall be placed in a clean, inert container
offering adequate protection from contamination, from loss of analytes by adsorption
to the internal wall of the container and against damage in transit. All necessary
precautions shall be taken to avoid change of composition of the aggregate and
laboratory samples which might arise during transportation or storage.
2.8. Sealing and labelling of aggregate and laboratory samples
Each sample taken for official use shall be sealed at the place of sampling and
identified following the Veterinary Services’ regulations. A record must be kept of
each sampling, permitting each lot to be identified unambiguously and giving the
CADMIUM, MERCURY AND 3-MCPD IN FOODSTUFFS
date and place of sampling together with any additional information likely to be of
assistance to the analyst.
3. SAMPLING PLANS
Sampling should ideally take place at the point where the commodity enters the
food chain and a discrete lot becomes identifiable. The sampling method applied
shall ensure that the aggregate sample is representative for the lot that is to be
controlled.
3.1. Number of incremental samples
In the case of liquid products for which a homogeneous distribution of the
contaminant in question can be assumed within a given lot, it is sufficient to take one
incremental sample per lot which forms the aggregate sample. Reference to the lot
number shall be given. Liquid products containing hydrolysed vegetable protein
(HVP) or liquid soya sauce shall be shaken well, or homogenised by other suitable
means, before the incremental sample is taken.
For other products, the minimum number of incremental samples to be taken from
the lot shall be as given in Table 1. The incremental samples shall be of similar
weight. Departure from this procedure must be recorded in the record provided for
under 2.8.
Table 1: Minimum number of incremental samples to be taken from the lot
Weight of lot (kg)
Minimum number of incremental samples to be taken
< 50
50 to 500
> 500
If the lot consists of individual packages, then the number of packages which shall
be taken to form the aggregate sample is given in Table 2.
Table 2: Number of packages (incremental samples) which shall be taken to form
the aggregate sample if the lot consists of individual packages
Number of packages or units in the lot
Number of packages or units to be taken
1 to 25
1 package or unit
26 to 100
About 5%, at least 2 packages or units
> 100
About 5%, at maximum 10 packages or units
4. COMPLIANCE OF THE LOT OR SUBLOT WITH THE SPECIFICATION
The control laboratory shall analyse the laboratory sample for enforcement at least
in two independent analyses, and calculate the mean of the results. The lot is
accepted if the mean conforms to the respective maximum level as laid down in
Regulation (EC) No 466/2001. It is rejected if the mean exceeds the respective
maximum level.
CADMIUM, MERCURY AND 3-MCPD IN FOODSTUFFS
For the purposes of these rules, and unless context
otherwise requires -
"aggregate sample" means the combined total of all the
incremental samples taken from the lot or sublot;
"the Commission" means the European Commission;
"the Community" means the European Community as established
under the Treaty establishing the European Community;
"the competent authority" means the Veterinary Services within
Malta as provided under article 2 of the Veterinary Services Act;
"incremental sample" means a quantity of material taken from a
single place in the lot or sublot;
"laboratory sample" means the sample intended for the
laboratory;
"lot" means an identifiable quantity of food delivered at one time
a n d d e t e r m i n e d b y th e v e t e r i n ary official to ha ve common
characteristics, such as origin, variety, type of packing, packer,
consignor or markings. In the case of fish, also the size of fish shall
be comparable;
"Member State" means a State which is a Member within the
European Community;
"sublot" means a designated part of a large lot in order to apply
the sampling method on that designated part. Each sublot must be
physically separated and identifiable;
"third country" means a State which is not a Member within the
European Community;
CADMIUM, MERCURY AND 3-MCPD IN FOODSTUFFS
"Veterinary Services" means the competent authority within the
territory of Malta as established under article 2 of the Veterinary
Services Act.
SAMPLE PREPARATION AND CRITERIA FOR METHODS OF ANALYSIS
USED IN OFFICAL CONTROL OF THE LEVELS OF LEAD, CADMIUM,
MERCURY AND 3-MCPD IN CERTAIN FOODSTUFFS
1. INTRODUCTION
The basic requirement is to obtain a representative and homogeneous laboratory
sample without introducing secondary contamination.
2. SPECIFIC SAMPLE
PREPARATION
PROCEDURES
FOR
LEAD,
CADMIUM AND MERCURY
There are many satisfactory specific sample preparation procedures which may be
used for the products under consideration. Those described in the draft CEN
Standard ‘Foodstuffs - Determination of trace elements - Performance criteria and
general consideration’ have been found to be satisfactory (a) but others may be
equally valid.
The following points must be noted for any procedure used
-
bivalve molluscs, crustaceans and small fish: where these are normally
eaten whole, the viscera are to be included in the material to be
analysed,
-
vegetables: only the edible portion of is to be tested, with note to be
taken of the requirements of the Regulation (EC) No 466/2001.
3. METHOD OF ANALYSIS TO BE USED BY THE LABORATORY AND
LABORATORY CONTROL REQUIREMENTS
3.1. Definitions
A number of the most commonly used definitions that the laboratory will be
required to use are given below
r = repeatability, the value below which the absolute difference between two
single test results obtained under repeatability conditions (i.e., same sample, same
operator, same apparatus, same laboratory, and short interval of time) may be
expected to lie within a specific probability (typically 95%) and hence r = 2,8 × sr.
sr = standard deviation, calculated from results generated under repeatability
conditions.
RSDr = relative standard deviation, calculated from results generated under
repeatability conditions [(sr / x -) × 100], where x - is the average of results over all
laboratories and samples.
R = reproducibility, the value below which the absolute difference between single
test results obtained under reproducibility conditions (i.e., on identical material
obtained by operators in different laboratories, using the standardised test method),
may be expected to lie within a certain probability (typically 95%); R = 2,8 × sR.
sR = standard deviation, calculated from results under reproducibility conditions.
RSDR = relative standard deviation calculated from results generated under
reproducibility conditions [(sR / x-) x 100]
HORRATr = the observed RSDr divided by the RSDr value estimated from the
Horwitz equation using the assumption r = 0,66R
HORRATR = the observed RSDR value divided by the RSDR value calculated
from the Horwitz equation (b).
CADMIUM, MERCURY AND 3-MCPD IN FOODSTUFFS
3.2. General requirements
Methods of analysis used for food control purposes must comply whenever
possible with the provisions of paragraphs 1 and 2 of the Annex to Directive 85/591/
EEC.
For the analysis of lead in wine, Commission Regulation (EEC) No 2676/90
determining Community methods for the analysis of wines lays down the method to
be used in Chapter 35 of its Annex.
3.3. Specific requirements
3.3.1. Lead, cadmium and mercury analyses
Specific methods for the determination of lead, cadmium and mercury contents are
not prescribed. Laboratories shall use a validated method that fulfils the performance
criteria indicated in Table 3. Where possible, the validation shall include a certified
reference material in the collaborative trial test materials.
Table 3: Performance criteria of methods for lead, cadmium and mercury analyses
Parameter
Value / comment
Applicability
Foods specified in Regulation (EC) No 466/2001
Detection limit
No more than one tenth of the value of the specification in
Regulation (EC) No 466/2001, except if the value of the
specification for lead is less than 0,1mg/kg. For the latter,
no more than one fifth of the value of the specification
Limit of quantification No more than one fifth of the value of the specification in
Regulation (EC) No 466/2001, except if the value of the
specification for lead is less than 0,1 mg`kg. For the latter,
no more than two fifths of the value of the specification
Precision
HORRATr or HORRATR values of less than 1,5 in the
validation collaborative trial
Recovery
80 - 120% (as indicated in the collaborative trial)
Specificity
Free from matrix or spectral interferences
3.3.2. 3-MCPD analysis
Specific methods for the determination of 3-MCPD contents are not prescribed.
Laboratories shall use a validated method that fulfils the performance criteria
indicated in Table 4. Where possible, the validation shall include a certified
reference material in the collaborative trial test materials. A specific method has
been validated by collaborative trial and has been shown to meet the requirements of
Table 4 (c).
Table 4: Performance criteria of methods for 3-MCPD analysis
Criterion
Recommended value
Concentration
Field blanks
Less than the detection limit
-
Recovery
75 - 110%
All
Limit of quantification
10 (or less) ìg/kg on a dry
-
matter basis
Standard deviation of the field
Less than 4 ìg/kg
-
blank signal
CADMIUM, MERCURY AND 3-MCPD IN FOODSTUFFS
In-house precision estimates -
< 4 ìg/kg
20 ìg/kg
standard deviation of replicate
< 6 ìg/kg
30 ìg/g
m e a s u r e m e n t s a t d i ff e r e n t
< 7 ìg/kg
40 ìg/kg
concentrations
< 8 ìg/kg
50 ìg/kg
< 15 ìg/kg
100 ìg/kg
3.4. Estimation of the analytical trueness and recovery calculations
Wherever possible the trueness of the analysis shall be estimated by including
suitable certified reference materials in the analytical run.
The ‘Harmonised Guidelines for the Use of Recovery Information in Analytical
Measurement’ (d) developed under the auspices of IUPAC/ISO/AOAC shall be taken
into account.
The analytical result shall be reported corrected or uncorrected. The manner of
reporting and the level of recovery must be reported.
3.5. Laboratory quality standards
Laboratories must comply with Directive 93/99/EEC.
3.6. Expression of results
The results shall be expressed in the same units as the maximum levels laid down
in Regulation (EC) No 466/2001.
Malta shall take all measures necessary to ensure that the
sampling for the official controls of the levels of lead, cadium,
mercury and 3-MCPD in foodstuffs is carried out in accordance
with the methods described in Schedule I.
Malta shall take all measures necessary to ensure that
sample preparation and methods of analyses used for the official
control of the levels of lead, cadmium, mercury and 3- MCPD in
foodstuffs comply with the criteria described in Schedule II to
these rules.
When Malta adopts these provisions, the provisions shall
contain a reference to these rules or shall be accompanied by such
reference at the time of their official publication. The procedure for
such reference shall be that applicable in Malta.
CADMIUM, MERCURY AND 3-MCPD IN FOODSTUFFS