Laws of Malta — Subsidiary Legislation 437.54 — REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *

REQUIREMENTS FOR THE DETERMINATION OF LEVELS

OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS

SUBSIDIARY LEGISLATION 437.54

REQUIREMENTS FOR THE DETERMINATION

OF LEVELS OF DIOXINS AND DIOXIN-LIKE

PCBs IN FEEDINGSTUFFS RULES *

15th March, 2005

LEGAL NOTICE 71 of 2005.

Laws of Malta — Subsidiary Legislation 437.54 — REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *

(1) The title of these rules is the Requirements for the

Determination of Levels of Dioxins and Dioxin-like PCBs in

Feedingstuffs Rules.

(2) The scope of these rules is to implement the rules found

under European Union Council Directive 2002/70/EC establishing

requirements for the determination of dioxins and dioxin-like PCBs

in feedingstuffs.

Laws of Malta — Subsidiary Legislation 437.54 — REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *

METHODS OF SAMPLING FOR OFFICIAL CONTROL OF THE LEVELS

OF DIOXINS (PCDD/PCDF) AND THE DETERMINATION

OF DIOXIN-LIKE PCBs IN CERTAIN FEEDINGSTUFFS

1. Purpose and scope

The samples intended for the official control of the levels of dioxins (PCDD/

PCDF) content, as well for the determination of the content of dioxin like PCBs (*)

in feedingstuffs, shall be taken according to the provisions of European Union

Commission Directive 76/371/EEC of 1 March 1976 establishing Community

methods of sampling for the official control of feedingstuffs. Aggregate samples

thus obtained shall be considered as representative for the lots or sublots from which

they are taken. Compliance with maximum levels laid down in European Union

Council Directive 1999/29/EC shall be established on the basis of the levels

determined in the laboratory samples.

2. Compliance of the lot or sublot with the specification

The control laboratory shall analyse the laboratory sample for enforcement in

duplicate analysis in case the obtained result of the first analysis is less than 20 %

below or above the maximum level, and calculate the mean of the results. The lot is

accepted if the result of the first analysis is more than 20% below the maximum level

or where duplicate analysis is necessary if the mean conforms to the respective

maximum level as laid down in European Union Council Directive 1999/29/EC.

* Table WHO TEFs for human risk assessment based on the conclusions of the World Health Organisation

meeting in Stockholm, Sweden, 15 to 18 June 1997 (Van den Berg et al., (1998) Toxic Equivalency Factors

(TEFs) for PCBs, PCDDs, PCDFs for Humans and for Wildlife. Environmental Health Perspectives,

106(12), 775).

Congener

TEF value

Congener

TEF value

Dibenzo-p-dioxins (PCDDs)

‘Dioxin-like’ PCBs: Non-ortho PCBs + Mono-

ortho PCBs

2,3,7,8-TCDD

Non-ortho PCBs

1,2,3,7,8-PeCDD

PCB 77

0,0001

1,2,3,4,7,8-HxCDD

0,1

PCB 81

0,0001

1,2,3,6,7,8-HxCDD

0,1

PCB 126

0,1

1,2,3,7,8,9-HxCDD

0,1

PCB 169

0,01

1,2,3,4,6,7,8-HpCDD

0,01

OCDD

0,0001

Mono-ortho PCBs

PCB 105

0,0001

Dibenzofurans (PCDFs)

PCB 114

0,0005

2,3,7,8-TCDF

0,1

PCB 118

0,0001

1,2,3,7,8-PeCDF

0,05

PCB 123

0,0001

2,3,4,7,8-PeCDF

0,5

PCB 156

0,0005

1,2,3,4,7,8-HxCDF

0,1

PCB 157

0,0005

1,2,3,6,7,8-HxCDF

0,1

PCB 167

0,00001

1,2,3,7,8,9-HxCDF

0,1

PCB 189

0,0001

2,3,4,6,7,8-HxCDF

0,1

1,2,3,4,6,7,8-HpCDF

0,01

1,2,3,4,7,8,9-HpCDF

0,01

OCDF

0,0001

Abbreviations used: T = tetra; Pe = penta; Hx = hexa; Hp = hepta; O = octa; CDD = chlorodibenzo-p-

dioxin; CDF = chlorodibenzofuran; CB = chlorobiphenyl.

Laws of Malta — Subsidiary Legislation 437.54 — REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *

For the purpose of these regulations -

"the competent authority" means the Veterinary Services within

Malta as provided under article 2 of the Veterinary Services Act, or

any other authority to which such responsibility has been delegated

by the Veterinary Services.

Laws of Malta — Subsidiary Legislation 437.54 — REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *

SAMPLE PREPARATION AND REQUIREMENTS FOR METHODS OF

ANALYSIS USED IN OFFICIAL CONTROL OF THE LEVELS OF DIOXINS

(PCDD/PCDF) AND THE DETERMINATION OF DIOXIN-LIKE PCBs IN

CERTAIN FEEDINGSTUFFS

1. Objective and field of application

These requirements should be applied where feed materials and feedingstuffs are

analysed for the determination of the dioxins (polychlorinated dibenzo-p-dioxins

(PCDD) and polychlorinated dibenzofurans (PCDF)) and dioxin-like polychlorinated

biphenyls (PCBs).

Monitoring for the presence of dioxins in feedingstuffs can be performed by a

strategy involving a screening method in order to select those samples with levels of

dioxins and dioxin-like PCBs that are less than 30% to 40% below or exceed the

level of interest. The concentration of dioxins in those samples with significant

levels needs to be determined/confirmed by a confirmatory method.

Screening methods are methods that are used to detect the presence of dioxins and

dioxin-like PCBs at the level of interest. These methods have a capacity for a high

sample throughput and are used to sift large numbers of samples for potential

positives. They are specifically designed to avoid false negatives.

C o n f i r m at o r y m e t h o d s a r e m e t h o ds t h a t p r o v i d e f u l l o r co m p l e m e nt a r y

information enabling the dioxins and dioxin-like PCBs to be identified and

quantified unequivocally at the level of interest.

2. Background

Because environmental and biological samples (including samples of feed

materials/feedingstuffs) in general contain complex mixtures of different dioxin

congeners, the concept of toxic equivalency factors (TEFs) has been developed to

facilitate risk assessment. These TEFs have been established to express

concentrations of mixtures of 2,3,7,8-substituted PCDDs and PCDFs, and more

recently, some non-ortho and mono-ortho chlorine substituted PCBs which possess

dioxin -like activity in toxic equivalents (TEQs) of 2,3,7,8-TCDD (see Schedule I,

footnote 1).

The concentrations of the individual substances in a given sample are multiplied

by their respective TEF and subsequently summed to give the total concentration of

dioxin-like compounds expressed in TEQs.

The concept of ‘upperbound’ requires using the limit of quantification for the

contribution of each nonquantified congener to the TEQ.

The concept of ‘lowerbound’ requires using zero for the contribution of each non-

quantified congener to the TEQ.

The concept of ‘mediumbound’ requires using half of the limit of quantification

calculating the contribution of each non-quantified congener to the TEQ.

3. Quality assurance requirements to be complied with for sample preparation

The general provisions on the preparation of samples for analysis as laid down in

the Annex to European Union Commission Directive 81/680/EEC of 30 July 1981

amending European Union Directives 71/250/EEC, 71/393/EEC, 72/199/EEC, 73/

46/EEC, 74/203/EEC, 75/84/EEC, 76/372/EEC and 78/633/EEC establishing

Community methods of analysis for the official control of feedingstuffs are

applicable.

In addition the following requirements have to be complied with

-

the samples must be stored and transported in glass, aluminium,

polypropylene or polyethylene containers. Traces of paper dust must be

removed from the sample container. Glassware should be rinsed with

solvents previously controlled for the presence of dioxins,

-

perform a blank analysis by carrying out the entire analytical procedure

omitting only the sample,

-

sample weight used for the extraction must be sufficient to fulfil the

requirements with respect to sensitivity.

4. Requirements for laboratories

-

Laboratories shall demonstrate the performance of a method in the range of

the level of interest, for example, 0,5 ×, 1 × and 2 × the level of interest with an

acceptable coefficient of variation for repeated analysis. For details of acceptance

criteria, see point 5.

-

Limit of quantification for a confirmatory method shall be in the range of

about one-fifth of the level of interest, to make sure that acceptable coefficients of

variations are met in the range of the level of interest.

-

Regular blank controls and spiking experiments or analysis of control

samples (preferably, if available, certified reference material) shall be performed as

internal quality control measures.

-

Successful participation in interlaboratory studies that assess laboratory

proficiency is the best way to prove the competence in specific analyses. However

successful participation in interlaboratory studies for, for example, soil or sewage

samples does not necessarily prove the competence also in the field of food or

feedingstuff samples, which present lower contamination levels. Therefore, the

continuous participation in interlaboratory studies for the determination of dioxins

and dioxin-like PCBs in the relevant feed/food matrices is mandatory.

-

Laboratories shall be accredited by a recognised body operating in

accordance with ISO Guide 58 to ensure that they are applying analytical quality

assurance. Laboratories should be accredited following the ISO/IEC/17025:1999

standard.

Laws of Malta — Subsidiary Legislation 437.54 — REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *

The competent authority shall ensure that the sampling for

the official control of the levels of dioxins and furans and the

determination of the levels of dioxin-like PCBs in feedingstuffs is

carried out in accordance with the methods described in Schedule I.

Laws of Malta — Subsidiary Legislation 437.54 — REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *

The competent authority shall ensure that sample

preparation and methods of analyses used for the official control of

the levels of dioxins and furans and the determination of the levels

of dioxin-like PCBs in feedingstuffs comply with the criteria

described in Schedule II.

*These rules have been repealed by Legal Notice 37 of 2025.

Laws of Malta — Subsidiary Legislation 437.54 — REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *

Requirements for the analytical procedures for dioxins and dioxin-like PCBs

Basic requirements for acceptance of analytical procedures

-

High sensitivity and low limits of detection. For PCDDs and PCDFs,

detectable quantities have to be in the picogram TEQ (10- 12 g) range because of

extreme toxicity of some of these compounds. PCBs are known to occur at higher

levels than the PCDDs and PCDFs. For most PCB congeners sensitivity in nanogram

(10- 9 g) range is already sufficient. However, for the measurement of the more toxic

dioxin-like PCB congeners (in particular non-ortho substituted congeners), the same

sensitivity must be reached as for the PCDDs and PCDFs.

-

High selectivity (specificity). A distinction is required for PCDDs, PCDFs

and dioxin-like PCBs from a multitude of other, coextracted and possibly interfering

compounds present at concentrations up to several orders of magnitude higher than

those of the analytes of interest. For gas chromatography/mass spectrometry (GC/

MS) methods, a differentiation among various congeners is necessary, such as

between toxic (e.g. the seventeen 2,3,7,8-substituted PCDDs and PCDFs and dioxin-

like PCBs) and other congeners. Bioassays should be able to determine TEQ values

selectively as the sum of PCDDs, PCDFs and dioxin-like PCBs.

-

High accuracy (trueness and precision). The determination should provide a

valid and reliable estimate of the true concentration in a sample. High accuracy

(accuracy of the measurement: the closeness of agreement between the result of a

measurement with the true or assigned value of the measurement) is necessary to

avoid the rejection of a sample analysis result on the basis of poor reliability of the

estimate of TEQ. Accuracy is expressed as trueness (difference between the mean

value measured for an analyte in a certified material and its certified value,

expressed as percentage of this value) and precision (precision is usually calculated

as a standard deviation including repeatability and reproducibility, and indicates the

closeness of agreement between the results obtained by applying the experimental

procedure several times under prescribed conditions).

Screening methods can comprise bioassays and GC/MS methods; confirmatory

methods are high resolution gas-chromatography/high-resolution mass-spectrometry

(HRGC/HRMS) methods. The following criteria have to be complied with on total

TEQ value

Screening methods

Confirmatory Levels

False negative rate

< 1%

Trueness

- 20% to + 20%

CV

< 30%

Laws of Malta — Subsidiary Legislation 437.54 — REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *

Specific requirements for GC/MS methods to be complied with for

screening or confirmatory purposes

-

Addition of 13C-labelled 2,3,7,8-chlorine substituted internal PCDD/F

standards (and of 13C-labelled internal dioxin-like PCB standards, if dioxin-like

PCBs have to be determined) must be carried out at the very beginning or start of the

analytical method, for example, prior to extraction in order to validate the analytical

procedure. At least one congener for each of the tetra to octachlorinated homologous

groups for PCDD/F (and at least one congener for each of the homologous groups for

dioxin-like PCBs, if dioxin-like PCBs have to be determined) must be added

(alternatively, at least one congener for each mass spectrometric selected ion

recording function used for monitoring PCDD/F and dioxin-like PCBs). There is a

clear preference, certainly in case of confirmatory methods, of using all 17 13C-

labelled 2,3,7,8-substituted internal PCDD/F standards and all 12 13C-labelled

internal dioxin-like PCB standard (if dioxin-like PCBs have to be determined).

Relative response factors should also be determined for those congeners for which

no 13C-labelled analogue is added by using appropriate calibration solutions.

-

For feedingstuffs of plant origin and feedingstuffs of animal origin

containing less than 10% fat, the addition of the internal standards is mandatory

prior to extraction. For feedingstuffs of animal origin containing more than 10% fat,

the internal standards can be added either before extraction or after fat extraction.

An appropriate validation of the extraction efficiency should be carried out,

depending on the stage at which internal standards are introduced and on whether

results are reported on a product or fat basis.

-

Prior to GC/MS analysis, one or two recovery (surrogate) standard(s) must

be added.

-

Control of recovery is necessary. For confirmatory methods, the recoveries

of the individual internal standards should be in the range of 60% to 120%. Lower or

higher recoveries for individual congeners, in particular for some hepta- and octa-

chlorinated dibenzodioxins and dibenzofurans, are acceptable on the condition that

their contribution to the TEQ value does not exceed 10% of the total TEQ value

(based on PCDD/F only). For screening methods, the recoveries should be in the

range of 30% to 140%.

-

Separation of dioxins from interfering chlorinated compounds such as PCBs

and chlorinated diphenyl ethers should be carried out by suitable chromatographic

techniques (preferably with a florisil, alumina and/or carbon column).

-

Gaschromatographic separation of isomers should be sufficient (< 25% peak

to peak between 1,2,3,4,7,8-HxCDF and 1,2,3,6,7,8-HxCDF).

-

Determination should be performed according to EPA Method 1613 revision

B: tetra-through octa-chlorinated dioxins and furans by isotope dilution HRGC/

HRMS or another with equivalent performance criteria.

-

The difference between upperbound level and lower bound level should not

exceed 20% for feedingstuffs with a dioxin contamination in the range or above the

maximum level. For feedingstuffs with contamination levels well below the

maximum level, the difference may be in the range of 25% to 40%.

Laws of Malta — Subsidiary Legislation 437.54 — REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *

Screening methods of analysis

7.1. Introduction

Different analytical approaches can be performed using a screening method: a

pure screening approach and a quantitative approach.

Screening approach

The response of samples is compared to that of a reference sample at the level of

interest. Samples with a response less than the reference are declared negative, those

with a higher response are suspected positives. Requirements

-

a blank and a reference sample(s) have to be included in each test series,

which is extracted and tested at the same time under identical

conditions. The reference sample must show a clearly elevated response

in comparison to a blank,

-

additional reference samples at 0,5 × and 2 × the level of interest should

be included to demonstrate the proper performance of the test in the

range of interest for the control of the level of interest,

-

when testing other matrices, the suitability of the reference sample(s)

has to be demonstrated, preferentially by including samples shown by

HRGC/HRMS to contain a TEQ level around that of the reference

sample or else a blank spiked at this level,

-

since no internal standards can be used in bioassays, tests on

repeatability are very important to obtain information on the standard

deviation within one test series. The coefficient of variation should be

below 30%,

-

for bioassays, the target compounds, possible interferences, and

maximum tolerable blank levels should be defined.

Quantitative approach

The quantitative approach requires standard dilution series, duplicate or triplicate

clean up and measuring as well as blank and recovery controls. The result may be

expressed as TEQ, thereby assuming that the compounds responsible for the signal

correspond to the TEQ principle. This can be performed by using TCDD (or a

dioxin/furan standard mixture) to produce a calibration curve to calculate the TEQ

level in the extract and thus in the sample. This is subsequently corrected for the

TEQ level calculated for a blank sample (to account for impurities from solvents and

chemicals used), and a recovery (calculated from the TEQ level in a quality control

sample around the limit of interest). It is essential to note that part of the apparent

recovery loss may be due to matrix effects and/or differences between the TEF

values in the bioassays and the official TEF values set by WHO.

7.2. Requirements for methods of analysis used for screening

-

GC/MS methods of analysis and bioassays may be used for screening. For

GC/MS methods the requirements as laid down in point 6 are to be used. For cell

based bioassays specific requirements are laid down in point 7.3 and for kit-based

bioassays in point 7.4.

-

Information on the number of false-positive and false-negative results of a

large set of samples below and above the maximum level or action level is necessary,

in comparison to the TEQ content as determined by a confirmatory method of

analysis. Actual false negative rates should be under 1 %. The rate of false positive

samples should be low enough to make the use of a screening tool advantageous.

-

Positive results have always to be confirmed by a confirmatory method of

analysis (HRGC/HRMS). In addition, samples from a wide TEQ-range should be

confirmed by HRGC/HRMS (approximately 2% to 10% of the negative samples).

Information on correspondence between bioassay and HRGC/HRMS results should

be made available.

7.3. Specific requirements for cell-based bioassays

-

When performing a bioassay, every test run requires a series of reference

concentration of TCDD or a dioxin/furan mixture (full dose-response curve with a

R2 > 0,95). However, for screening purposes, an expanded low-level curve for

analysing low-level samples could be used.

-

A TCDD reference concentration (about three times the limit of

quantification) on a quality control sheet should be used for the outcome of the

bioassay over a constant time period. An alternative could be the relative response of

a reference sample in comparison to the TCDD calibration line since the response of

the cells may depend on many factors.

-

Quality control (QC) charts for each type of reference material should be

recorded and checked to make sure the outcome is in accordance with the stated

guidelines.

-

In particular for quantitative calculations, the induction of the sample

dilution used must be within the linear portion of the response curve. Samples above

the linear portion of the response curve must be diluted and re-tested. Therefore, at

least three or more dilutions at one time are recommended to be tested.

-

The percent standard deviation should not be above 15% in a triplicate

determination for each sample dilution and not above 30% betwee n t hr e e

independent experiments.

-

The limit of detection may be set as three times the standard deviation of the

solvent blank or of the background response. Another approach is to apply a

response that is above the background (induction factor five times the solvent blank)

calculated from the calibration curve of the day. The limit of quantification may be

set as five to six times the standard deviation of the solvent blank or of the

background response or to apply a response that is clearly above the background

(induction factor 10 times the solvent blank) calculated from the calibration curve of

the day.

7.4. Specific requirements for kit-based bioassays ( * )

-

Manufacturer’s instructions for sample preparation and analyses have to be

followed.

-

Test kits should not be used after the expiration date.

-

Materials or components designed for use with other kits should not be used.

-

Test kits should be kept within the specified range of storage temperature

and used at the specified operating temperature.

-

The limit of detection for immunoassays is determined as the sum of the

mean and three times the standard deviation, based on 10 replicate analysis of the

blank, to be divided by the slope value of the linear regression equation.

-

Reference standards should be used for tests at the laboratory to make sure

that the responsiveness to the standard is within an acceptable range.

Laws of Malta — Subsidiary Legislation 437.54 — REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *

Reporting of results

Insofar as the used analytical procedure makes it possible, the analytical results

should contain the levels of the individual PCDD/F and PCB congeners and be

reported as lowerbound, upperbound and mediumbound in order to include a

maximum of information in the reporting of the results and thereby enabling the

interpretation of the results according to specific requirements.

The report should also include the lipid content of the sample as well the method

used for lipid extraction.

The recoveries of the individual internal standards must be made available in case

the recoveries are outside the range mentioned in point 6, in case the maximum level

is exceeded and in the other cases upon request.

*No evidence have yet been submitted of commercially available kit-based bioassays having sufficient

sensitivity and reliability to be used for screening for the presence of dioxins at the required levels in

samples of foodstuffs and feedingstuffs.