REQUIREMENTS FOR THE DETERMINATION OF LEVELS OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS RULES *
Table of Provisions (11)
Statutory Text (11 Articles)
REQUIREMENTS FOR THE DETERMINATION OF LEVELS
OF DIOXINS AND DIOXIN-LIKE PCBs IN FEEDINGSTUFFS
SUBSIDIARY LEGISLATION 437.54
REQUIREMENTS FOR THE DETERMINATION
OF LEVELS OF DIOXINS AND DIOXIN-LIKE
PCBs IN FEEDINGSTUFFS RULES *
15th March, 2005
LEGAL NOTICE 71 of 2005.
(1) The title of these rules is the Requirements for the
Determination of Levels of Dioxins and Dioxin-like PCBs in
Feedingstuffs Rules.
(2) The scope of these rules is to implement the rules found
under European Union Council Directive 2002/70/EC establishing
requirements for the determination of dioxins and dioxin-like PCBs
in feedingstuffs.
METHODS OF SAMPLING FOR OFFICIAL CONTROL OF THE LEVELS
OF DIOXINS (PCDD/PCDF) AND THE DETERMINATION
OF DIOXIN-LIKE PCBs IN CERTAIN FEEDINGSTUFFS
1. Purpose and scope
The samples intended for the official control of the levels of dioxins (PCDD/
PCDF) content, as well for the determination of the content of dioxin like PCBs (*)
in feedingstuffs, shall be taken according to the provisions of European Union
Commission Directive 76/371/EEC of 1 March 1976 establishing Community
methods of sampling for the official control of feedingstuffs. Aggregate samples
thus obtained shall be considered as representative for the lots or sublots from which
they are taken. Compliance with maximum levels laid down in European Union
Council Directive 1999/29/EC shall be established on the basis of the levels
determined in the laboratory samples.
2. Compliance of the lot or sublot with the specification
The control laboratory shall analyse the laboratory sample for enforcement in
duplicate analysis in case the obtained result of the first analysis is less than 20 %
below or above the maximum level, and calculate the mean of the results. The lot is
accepted if the result of the first analysis is more than 20% below the maximum level
or where duplicate analysis is necessary if the mean conforms to the respective
maximum level as laid down in European Union Council Directive 1999/29/EC.
* Table WHO TEFs for human risk assessment based on the conclusions of the World Health Organisation
meeting in Stockholm, Sweden, 15 to 18 June 1997 (Van den Berg et al., (1998) Toxic Equivalency Factors
(TEFs) for PCBs, PCDDs, PCDFs for Humans and for Wildlife. Environmental Health Perspectives,
106(12), 775).
Congener
TEF value
Congener
TEF value
Dibenzo-p-dioxins (PCDDs)
‘Dioxin-like’ PCBs: Non-ortho PCBs + Mono-
ortho PCBs
2,3,7,8-TCDD
Non-ortho PCBs
1,2,3,7,8-PeCDD
PCB 77
0,0001
1,2,3,4,7,8-HxCDD
0,1
PCB 81
0,0001
1,2,3,6,7,8-HxCDD
0,1
PCB 126
0,1
1,2,3,7,8,9-HxCDD
0,1
PCB 169
0,01
1,2,3,4,6,7,8-HpCDD
0,01
OCDD
0,0001
Mono-ortho PCBs
PCB 105
0,0001
Dibenzofurans (PCDFs)
PCB 114
0,0005
2,3,7,8-TCDF
0,1
PCB 118
0,0001
1,2,3,7,8-PeCDF
0,05
PCB 123
0,0001
2,3,4,7,8-PeCDF
0,5
PCB 156
0,0005
1,2,3,4,7,8-HxCDF
0,1
PCB 157
0,0005
1,2,3,6,7,8-HxCDF
0,1
PCB 167
0,00001
1,2,3,7,8,9-HxCDF
0,1
PCB 189
0,0001
2,3,4,6,7,8-HxCDF
0,1
1,2,3,4,6,7,8-HpCDF
0,01
1,2,3,4,7,8,9-HpCDF
0,01
OCDF
0,0001
Abbreviations used: T = tetra; Pe = penta; Hx = hexa; Hp = hepta; O = octa; CDD = chlorodibenzo-p-
dioxin; CDF = chlorodibenzofuran; CB = chlorobiphenyl.
For the purpose of these regulations -
"the competent authority" means the Veterinary Services within
Malta as provided under article 2 of the Veterinary Services Act, or
any other authority to which such responsibility has been delegated
by the Veterinary Services.
SAMPLE PREPARATION AND REQUIREMENTS FOR METHODS OF
ANALYSIS USED IN OFFICIAL CONTROL OF THE LEVELS OF DIOXINS
(PCDD/PCDF) AND THE DETERMINATION OF DIOXIN-LIKE PCBs IN
CERTAIN FEEDINGSTUFFS
1. Objective and field of application
These requirements should be applied where feed materials and feedingstuffs are
analysed for the determination of the dioxins (polychlorinated dibenzo-p-dioxins
(PCDD) and polychlorinated dibenzofurans (PCDF)) and dioxin-like polychlorinated
biphenyls (PCBs).
Monitoring for the presence of dioxins in feedingstuffs can be performed by a
strategy involving a screening method in order to select those samples with levels of
dioxins and dioxin-like PCBs that are less than 30% to 40% below or exceed the
level of interest. The concentration of dioxins in those samples with significant
levels needs to be determined/confirmed by a confirmatory method.
Screening methods are methods that are used to detect the presence of dioxins and
dioxin-like PCBs at the level of interest. These methods have a capacity for a high
sample throughput and are used to sift large numbers of samples for potential
positives. They are specifically designed to avoid false negatives.
C o n f i r m at o r y m e t h o d s a r e m e t h o ds t h a t p r o v i d e f u l l o r co m p l e m e nt a r y
information enabling the dioxins and dioxin-like PCBs to be identified and
quantified unequivocally at the level of interest.
2. Background
Because environmental and biological samples (including samples of feed
materials/feedingstuffs) in general contain complex mixtures of different dioxin
congeners, the concept of toxic equivalency factors (TEFs) has been developed to
facilitate risk assessment. These TEFs have been established to express
concentrations of mixtures of 2,3,7,8-substituted PCDDs and PCDFs, and more
recently, some non-ortho and mono-ortho chlorine substituted PCBs which possess
dioxin -like activity in toxic equivalents (TEQs) of 2,3,7,8-TCDD (see Schedule I,
footnote 1).
The concentrations of the individual substances in a given sample are multiplied
by their respective TEF and subsequently summed to give the total concentration of
dioxin-like compounds expressed in TEQs.
The concept of ‘upperbound’ requires using the limit of quantification for the
contribution of each nonquantified congener to the TEQ.
The concept of ‘lowerbound’ requires using zero for the contribution of each non-
quantified congener to the TEQ.
The concept of ‘mediumbound’ requires using half of the limit of quantification
calculating the contribution of each non-quantified congener to the TEQ.
3. Quality assurance requirements to be complied with for sample preparation
The general provisions on the preparation of samples for analysis as laid down in
the Annex to European Union Commission Directive 81/680/EEC of 30 July 1981
amending European Union Directives 71/250/EEC, 71/393/EEC, 72/199/EEC, 73/
46/EEC, 74/203/EEC, 75/84/EEC, 76/372/EEC and 78/633/EEC establishing
Community methods of analysis for the official control of feedingstuffs are
applicable.
In addition the following requirements have to be complied with
-
the samples must be stored and transported in glass, aluminium,
polypropylene or polyethylene containers. Traces of paper dust must be
removed from the sample container. Glassware should be rinsed with
solvents previously controlled for the presence of dioxins,
-
perform a blank analysis by carrying out the entire analytical procedure
omitting only the sample,
-
sample weight used for the extraction must be sufficient to fulfil the
requirements with respect to sensitivity.
4. Requirements for laboratories
-
Laboratories shall demonstrate the performance of a method in the range of
the level of interest, for example, 0,5 ×, 1 × and 2 × the level of interest with an
acceptable coefficient of variation for repeated analysis. For details of acceptance
criteria, see point 5.
-
Limit of quantification for a confirmatory method shall be in the range of
about one-fifth of the level of interest, to make sure that acceptable coefficients of
variations are met in the range of the level of interest.
-
Regular blank controls and spiking experiments or analysis of control
samples (preferably, if available, certified reference material) shall be performed as
internal quality control measures.
-
Successful participation in interlaboratory studies that assess laboratory
proficiency is the best way to prove the competence in specific analyses. However
successful participation in interlaboratory studies for, for example, soil or sewage
samples does not necessarily prove the competence also in the field of food or
feedingstuff samples, which present lower contamination levels. Therefore, the
continuous participation in interlaboratory studies for the determination of dioxins
and dioxin-like PCBs in the relevant feed/food matrices is mandatory.
-
Laboratories shall be accredited by a recognised body operating in
accordance with ISO Guide 58 to ensure that they are applying analytical quality
assurance. Laboratories should be accredited following the ISO/IEC/17025:1999
standard.
The competent authority shall ensure that the sampling for
the official control of the levels of dioxins and furans and the
determination of the levels of dioxin-like PCBs in feedingstuffs is
carried out in accordance with the methods described in Schedule I.
The competent authority shall ensure that sample
preparation and methods of analyses used for the official control of
the levels of dioxins and furans and the determination of the levels
of dioxin-like PCBs in feedingstuffs comply with the criteria
described in Schedule II.
*These rules have been repealed by Legal Notice 37 of 2025.
Requirements for the analytical procedures for dioxins and dioxin-like PCBs
Basic requirements for acceptance of analytical procedures
-
High sensitivity and low limits of detection. For PCDDs and PCDFs,
detectable quantities have to be in the picogram TEQ (10- 12 g) range because of
extreme toxicity of some of these compounds. PCBs are known to occur at higher
levels than the PCDDs and PCDFs. For most PCB congeners sensitivity in nanogram
(10- 9 g) range is already sufficient. However, for the measurement of the more toxic
dioxin-like PCB congeners (in particular non-ortho substituted congeners), the same
sensitivity must be reached as for the PCDDs and PCDFs.
-
High selectivity (specificity). A distinction is required for PCDDs, PCDFs
and dioxin-like PCBs from a multitude of other, coextracted and possibly interfering
compounds present at concentrations up to several orders of magnitude higher than
those of the analytes of interest. For gas chromatography/mass spectrometry (GC/
MS) methods, a differentiation among various congeners is necessary, such as
between toxic (e.g. the seventeen 2,3,7,8-substituted PCDDs and PCDFs and dioxin-
like PCBs) and other congeners. Bioassays should be able to determine TEQ values
selectively as the sum of PCDDs, PCDFs and dioxin-like PCBs.
-
High accuracy (trueness and precision). The determination should provide a
valid and reliable estimate of the true concentration in a sample. High accuracy
(accuracy of the measurement: the closeness of agreement between the result of a
measurement with the true or assigned value of the measurement) is necessary to
avoid the rejection of a sample analysis result on the basis of poor reliability of the
estimate of TEQ. Accuracy is expressed as trueness (difference between the mean
value measured for an analyte in a certified material and its certified value,
expressed as percentage of this value) and precision (precision is usually calculated
as a standard deviation including repeatability and reproducibility, and indicates the
closeness of agreement between the results obtained by applying the experimental
procedure several times under prescribed conditions).
Screening methods can comprise bioassays and GC/MS methods; confirmatory
methods are high resolution gas-chromatography/high-resolution mass-spectrometry
(HRGC/HRMS) methods. The following criteria have to be complied with on total
TEQ value
Screening methods
Confirmatory Levels
False negative rate
< 1%
Trueness
- 20% to + 20%
CV
< 30%
Specific requirements for GC/MS methods to be complied with for
screening or confirmatory purposes
-
Addition of 13C-labelled 2,3,7,8-chlorine substituted internal PCDD/F
standards (and of 13C-labelled internal dioxin-like PCB standards, if dioxin-like
PCBs have to be determined) must be carried out at the very beginning or start of the
analytical method, for example, prior to extraction in order to validate the analytical
procedure. At least one congener for each of the tetra to octachlorinated homologous
groups for PCDD/F (and at least one congener for each of the homologous groups for
dioxin-like PCBs, if dioxin-like PCBs have to be determined) must be added
(alternatively, at least one congener for each mass spectrometric selected ion
recording function used for monitoring PCDD/F and dioxin-like PCBs). There is a
clear preference, certainly in case of confirmatory methods, of using all 17 13C-
labelled 2,3,7,8-substituted internal PCDD/F standards and all 12 13C-labelled
internal dioxin-like PCB standard (if dioxin-like PCBs have to be determined).
Relative response factors should also be determined for those congeners for which
no 13C-labelled analogue is added by using appropriate calibration solutions.
-
For feedingstuffs of plant origin and feedingstuffs of animal origin
containing less than 10% fat, the addition of the internal standards is mandatory
prior to extraction. For feedingstuffs of animal origin containing more than 10% fat,
the internal standards can be added either before extraction or after fat extraction.
An appropriate validation of the extraction efficiency should be carried out,
depending on the stage at which internal standards are introduced and on whether
results are reported on a product or fat basis.
-
Prior to GC/MS analysis, one or two recovery (surrogate) standard(s) must
be added.
-
Control of recovery is necessary. For confirmatory methods, the recoveries
of the individual internal standards should be in the range of 60% to 120%. Lower or
higher recoveries for individual congeners, in particular for some hepta- and octa-
chlorinated dibenzodioxins and dibenzofurans, are acceptable on the condition that
their contribution to the TEQ value does not exceed 10% of the total TEQ value
(based on PCDD/F only). For screening methods, the recoveries should be in the
range of 30% to 140%.
-
Separation of dioxins from interfering chlorinated compounds such as PCBs
and chlorinated diphenyl ethers should be carried out by suitable chromatographic
techniques (preferably with a florisil, alumina and/or carbon column).
-
Gaschromatographic separation of isomers should be sufficient (< 25% peak
to peak between 1,2,3,4,7,8-HxCDF and 1,2,3,6,7,8-HxCDF).
-
Determination should be performed according to EPA Method 1613 revision
B: tetra-through octa-chlorinated dioxins and furans by isotope dilution HRGC/
HRMS or another with equivalent performance criteria.
-
The difference between upperbound level and lower bound level should not
exceed 20% for feedingstuffs with a dioxin contamination in the range or above the
maximum level. For feedingstuffs with contamination levels well below the
maximum level, the difference may be in the range of 25% to 40%.
Screening methods of analysis
7.1. Introduction
Different analytical approaches can be performed using a screening method: a
pure screening approach and a quantitative approach.
Screening approach
The response of samples is compared to that of a reference sample at the level of
interest. Samples with a response less than the reference are declared negative, those
with a higher response are suspected positives. Requirements
-
a blank and a reference sample(s) have to be included in each test series,
which is extracted and tested at the same time under identical
conditions. The reference sample must show a clearly elevated response
in comparison to a blank,
-
additional reference samples at 0,5 × and 2 × the level of interest should
be included to demonstrate the proper performance of the test in the
range of interest for the control of the level of interest,
-
when testing other matrices, the suitability of the reference sample(s)
has to be demonstrated, preferentially by including samples shown by
HRGC/HRMS to contain a TEQ level around that of the reference
sample or else a blank spiked at this level,
-
since no internal standards can be used in bioassays, tests on
repeatability are very important to obtain information on the standard
deviation within one test series. The coefficient of variation should be
below 30%,
-
for bioassays, the target compounds, possible interferences, and
maximum tolerable blank levels should be defined.
Quantitative approach
The quantitative approach requires standard dilution series, duplicate or triplicate
clean up and measuring as well as blank and recovery controls. The result may be
expressed as TEQ, thereby assuming that the compounds responsible for the signal
correspond to the TEQ principle. This can be performed by using TCDD (or a
dioxin/furan standard mixture) to produce a calibration curve to calculate the TEQ
level in the extract and thus in the sample. This is subsequently corrected for the
TEQ level calculated for a blank sample (to account for impurities from solvents and
chemicals used), and a recovery (calculated from the TEQ level in a quality control
sample around the limit of interest). It is essential to note that part of the apparent
recovery loss may be due to matrix effects and/or differences between the TEF
values in the bioassays and the official TEF values set by WHO.
7.2. Requirements for methods of analysis used for screening
-
GC/MS methods of analysis and bioassays may be used for screening. For
GC/MS methods the requirements as laid down in point 6 are to be used. For cell
based bioassays specific requirements are laid down in point 7.3 and for kit-based
bioassays in point 7.4.
-
Information on the number of false-positive and false-negative results of a
large set of samples below and above the maximum level or action level is necessary,
in comparison to the TEQ content as determined by a confirmatory method of
analysis. Actual false negative rates should be under 1 %. The rate of false positive
samples should be low enough to make the use of a screening tool advantageous.
-
Positive results have always to be confirmed by a confirmatory method of
analysis (HRGC/HRMS). In addition, samples from a wide TEQ-range should be
confirmed by HRGC/HRMS (approximately 2% to 10% of the negative samples).
Information on correspondence between bioassay and HRGC/HRMS results should
be made available.
7.3. Specific requirements for cell-based bioassays
-
When performing a bioassay, every test run requires a series of reference
concentration of TCDD or a dioxin/furan mixture (full dose-response curve with a
R2 > 0,95). However, for screening purposes, an expanded low-level curve for
analysing low-level samples could be used.
-
A TCDD reference concentration (about three times the limit of
quantification) on a quality control sheet should be used for the outcome of the
bioassay over a constant time period. An alternative could be the relative response of
a reference sample in comparison to the TCDD calibration line since the response of
the cells may depend on many factors.
-
Quality control (QC) charts for each type of reference material should be
recorded and checked to make sure the outcome is in accordance with the stated
guidelines.
-
In particular for quantitative calculations, the induction of the sample
dilution used must be within the linear portion of the response curve. Samples above
the linear portion of the response curve must be diluted and re-tested. Therefore, at
least three or more dilutions at one time are recommended to be tested.
-
The percent standard deviation should not be above 15% in a triplicate
determination for each sample dilution and not above 30% betwee n t hr e e
independent experiments.
-
The limit of detection may be set as three times the standard deviation of the
solvent blank or of the background response. Another approach is to apply a
response that is above the background (induction factor five times the solvent blank)
calculated from the calibration curve of the day. The limit of quantification may be
set as five to six times the standard deviation of the solvent blank or of the
background response or to apply a response that is clearly above the background
(induction factor 10 times the solvent blank) calculated from the calibration curve of
the day.
7.4. Specific requirements for kit-based bioassays ( * )
-
Manufacturer’s instructions for sample preparation and analyses have to be
followed.
-
Test kits should not be used after the expiration date.
-
Materials or components designed for use with other kits should not be used.
-
Test kits should be kept within the specified range of storage temperature
and used at the specified operating temperature.
-
The limit of detection for immunoassays is determined as the sum of the
mean and three times the standard deviation, based on 10 replicate analysis of the
blank, to be divided by the slope value of the linear regression equation.
-
Reference standards should be used for tests at the laboratory to make sure
that the responsiveness to the standard is within an acceptable range.
Reporting of results
Insofar as the used analytical procedure makes it possible, the analytical results
should contain the levels of the individual PCDD/F and PCB congeners and be
reported as lowerbound, upperbound and mediumbound in order to include a
maximum of information in the reporting of the results and thereby enabling the
interpretation of the results according to specific requirements.
The report should also include the lipid content of the sample as well the method
used for lipid extraction.
The recoveries of the individual internal standards must be made available in case
the recoveries are outside the range mentioned in point 6, in case the maximum level
is exceeded and in the other cases upon request.
*No evidence have yet been submitted of commercially available kit-based bioassays having sufficient
sensitivity and reliability to be used for screening for the presence of dioxins at the required levels in
samples of foodstuffs and feedingstuffs.