AEROSOL DISPENSERS REGULATIONS
Table of Provisions (9)
Statutory Text (9 Articles)
AEROSOL DISPENSERS
SUBSIDIARY LEGISLATION 427.26
AEROSOL DISPENSERS REGULATIONS
1st July, 2002
LEGAL NOTICE 145 of 2002, as amended by Legal Notices 26 of 2009,
94 of 2011, 395 of 2013 and 93 of 2017.
1. The title of these regulations is the Aerosol Dispensers
Regulations.
1.2. These regulations shall become operative on the 1st July,
2002
Provided that the requirements to provide information to
the European Commission referred to in regulation 7.3 shall come
into force on such date as the Minister responsible for Consumer
Affairs, after consultation with the Malta Standards Authority, may
prescribe. *
Amended by
L.N. 26 of 2009;
Based on the Annex of the Directive
L.N. 395 of 2013;
L.N. 93 of 2017.
1. DEFINITIONS
1.1. Pressures
'Pressures' means the internal pressures in bars (relative pressures).
1.2. Test pressure
'Test pressure' means the pressure to which an unfilled aerosol dispenser
container may be subjected for 25 seconds without any leakage being caused or, in
the case of metal or plastic containers, any visible or permanent distortion except as
allowed under point 6.1.1.2 of this Schedule.
1.3. Bursting pressure
'Bursting pressure' means the minimum pressure which causes the aerosol
dispenser container to burst or rupture.
1.4. Total capacity of the container
'Total capacity of the container' means the volume in millimetres of an open
container up to the rim of the opening.
1.5. Net capacity
'Net capacity' means the volume in millimetres of a filled and closed aerosol
dispenser.
1.6. Volume of the liquid phase
'Volume of liquid phase' means the volume of the non-gaseous phases in the
filled and closed aerosol dispenser.
1.7. Test conditions
'Test conditions' means the values of the test and bursting pressures exerted
hydraulically at 20ºC (± 5ºC).
1.7a. Substance
"Substance" means substance as defined in Article 2(7) of Regulation (EC)
No 1272/2008.
1.7b. Mixture
"Mixture” means mixture as defined in Article 2(8) of Regulation (EC) No
1272/2008.
1.8. Flammable contents
Contents of aerosols shall be considered as flammable if they contain any
component which is classified as flammable
1.8.1
flammable liquid means a liquid having a flashpoint of not more
than 93°C;
1.8.2
flammable solid means a solid substance or mixture which is readily
combustible, or may cause or contribute to fire as a result of
friction. Readily combustible solids are powdered, granular, or
pasty substances or mixtures which are dangerous if they can be
easily ignited by brief contact with an ignition source, such as a
AEROSOL DISPENSERS
burning match, and if the flame spreads rapidly; and
flammable gas means a gas or gas mixture having a flammable
range with air at 20°C and a standard pressure of 1,013 bar;
This definition does not cover pyrophoric, self-heating or water-reactive
substances and mixtures, which shall never be components of aerosol contents.
1.9. Flammable aerosols
For the purpose of this Directive, an aerosol is considered as "non-flammable",
"flammable" or "extremely flammable" according to its chemical heat of combustion
and mass content of flammable components, as follows
(a) the aerosol is classified as "extremely flammable" if it contains 85% or
more flammable components and the chemical heat of combustion
exceeds or is equal to 30 kJ/g;
(b) the aerosol is classified as "non-flammable" if it contains 1% or less
flammable components and the chemical heat of combustion is less than
20 kJ/g; and
(c) all other aerosols will be submitted to the following flammability
classification procedures or shall be classified as "extremely
flammable". The ignition distance test, the enclosed space test and the
foam flammability test shall comply with point 6.3.
Flammable spray aerosols
In the case of spray aerosols the classification shall be made taking
into account the chemical heat of combustion and on the basis of the
results of the ignition distance test, as follows
1.9.1.1
If the chemical heat of combustion is less than 20 kJ/g
1.9.1.1.1
the aerosol is classified as "flammable" if
ignition occurs at a distance equal or greater
than 15 cm but less than 75 cm;
1.9.1.1.2
the aerosol is classified as "extremely
flammable" if ignition occurs at a distance of
75 cm or more; and
1.9.1.1.3
if no ignition occurs in the ignition distance
test, the enclosed space test shall be
performed and in this case, the aerosol is
classified as "flammable" if the time
equivalent is less than or equal to 300 s/m3 or
the deflagration density is less than or equal
to 300 g/m3; otherwise the aerosol is
classified as "non-flammable".
1.9.1.2
If the chemical heat of combustion is equal to or more
than 20 kJ/g, the aerosol is classified as "extremely
flammable" if ignition occurs at a distance of 75 cm or
more; otherwise the aerosol is classified as "flammable".
Flammable foam aerosols
In the case of foam aerosols, the classification shall be made on the
basis of the results of the foam flammability test.
1.9.2.1
The aerosol product shall be classified as "extremely
flammable" if
1.9.2.1.1
the flame height is 20 cm or more and the
flame duration is two seconds or more; or
1.9.2.1.2
the flame height is 4 cm or more and the
flame duration is seven seconds or more.
1.9.2.2
The aerosol product which does not meet the criteria in
(a) is classified as "flammable" if the flame height is 4 cm
or more and the flame duration is two seconds or more.
1.10. Chemical Heat of Combustion
The chemical heat of combustion ΔHc shall be either determined by
1.10.1
acknowledged rules of technology, described e.g. in standards such
as ASTM D 240, ISO 13943 86.1 to 86.3 and NFPA 30B, or found
in the scientifically established literature; or
1.10.2
applying the following calculation method
The chemical heat of combustion (ΔHc), in kilojoules per gram (kJ/
g), can be calculated as the product of the theoretical heat of
combustion (ΔHcomb), and a combustion efficiency, usually less
than 1,0 (a typical combustion efficiency is 0,95 or 95%).
For a composite aerosol formulation, the chemical heat of
combustion is the summation of the weighted heats of combustion
for the individual components, as follows
n
[w i % ΔH C(i) ]
ΔH c =
i
where
ΔHc = chemical heat of combustion (kJ/g) of the product;
wi% = mass fraction of component i in the product;
ΔHc(i) = specific heat of combustion (kJ/g) of component i in the product.
The person responsible for the marketing of the aerosol dispenser shall describe
the method used for determining the chemical heat of combustion in a document to
be made readily available in an official Community language at the address specified
on the label in accordance with point 5.2.1 of regulation 5.2, if the chemical heat of
combustion is used as a parameter for assessing the flammability of aerosols
according to the provisions of this regulation.
2. GENERAL PROVISIONS
2.0 Without prejudice to specific provisions of the Annex on requirements
related to the flammability and pressure hazard, the person responsible for the
marketing of aerosol dispensers is under an obligation to analyse the hazards in order
to identify those which apply to his aerosol dispensers. Where appropriate, this
analysis shall include a consideration of the risks resulting from the inhalation of the
spray ejected by the aerosol dispenser under normal and reasonably foreseeable
conditions of use, taking into account droplet size distribution in conjunction with
physical and chemical properties of the contents. He must then design, construct and
test it and, if applicable, draft special statements concerning its use, taking account
of his analysis.
2.1. Construction and equipment
AEROSOL DISPENSERS
The filled aerosol dispenser must be such that, under normal
conditions of use and storage, it complies with the provisions of this
Schedule.
The value must enable the aerosol to be virtually hermetically
sealed under normal conditions of storage or transport and must be
protected, for example by means of a protective cap, against any
unintentional opening and any deterioration.
There must be no possibility that the mechanical resistance of the
aerosol dispenser can be impaired by the action of the substances
contained in it, even during prolonged storage.
2.2. Labelling
Without prejudice to Regulation (EC) No 1272/2008, each aerosol dispenser
must visibly bear the following legible and indelible marking
(a) where the aerosol is classified as ‘non-flammable’ according to the
criteria of point 1.9, the signal word ‘Warning’ and the other label
elements for Aerosols Category 3 provided for in Table 2.3.1 of Annex I
to Regulation (EC) No 1272/2008;
(b) where the aerosol is classified as ‘flammable’ according to the criteria
of point 1.9, the signal word ‘Warning’ and the other label elements for
Aerosols Category 2 provided for in Table 2.3.1 of Annex I to
Regulation (EC) No 1272/2008;
(c) where the aerosol is classified as ‘extremely flammable’ according to
the criteria of point 1.9, the signal word ‘Danger’ and the other label
elements for Aerosols Category 1 provided for in Table 2.3.1 of Annex I
to Regulation (EC) No 1272/2008;
(d) where the aerosol dispenser is a consumer product, the precautionary
statement P102 provided for in Part 1, Table 6.1 of Annex IV to
Regulation (EC) No 1272/2008;
(e) any additional operating precautions which alert consumers to the specific
dangers of the product; if the aerosol dispenser is accompanied by separate
instructions for use, the latter must also reflect such operating precautions.
2.3. Volume of the liquid phase
The volume of the liquid phase at 50 °C must not exceed 90 % of the net
3. SPECIAL PROVISION FOR METAL AEROSOL DISPENSERS
3.1. Capacity
The total capacity of these containers may not exceed 1 000 ml.
3.1.1. Test pressure of containers
(a) For containers filled with a pressure of less than 6.7 bars at
50ºC, the test pressure must be equal to at least 10 bars.
(b) For containers filled at a pressure equal to or greater than 6.7
bars at 50ºC, the test pressure must be 50% higher than the
internal pressure at 50ºC.
3.1.2. Filling
The pressure at 50°C in the aerosol dispenser must not exceed the
values provided for in the following table, depending upon the
content of gases in the aerosol dispenser
Pressure at
Content of gases
50°C
Liquefied gas or mixture of gases having a
flammable range with air at 20°C and a standard
12 bar
pressure of 1,013 bar
Liquefied gas or mixture of gases not having a
flammable range with air at 20°C and a standard
13,2 bar
pressure of 1,013 bar
Compressed gases or gases dissolved under
pressure not having a flammable range with air at
15 bar
20°C and a standard pressure of 1,013 bar
4. SPECIAL PROVISIONS FOR GLASS AEROSOL DISPENSERS
4.1. Plastic coated or permanently protected containers
Containers of this type may be used for filling compressed, liquefied or
4.1.1. Capacity
The total capacity of such containers may not exceed 220 ml.
4.1.2. Coating
The coating must be a protective envelope of plastic or other
suitable material, intended to prevent the risk of flying particles of
the glass if the container is accidentally broken, and must be so
designed that there are no flying particles of glass if the filled
aerosol dispenser, brought to a temperature of 20ºC, is dropped from
a height of 1.8 m onto a concrete floor.
4.1.3. Test pressure of container
(a) Containers used for filling with compressed or dissolved gas
must resist a test pressure equal to at least 12 bars.
(b) Containers used for filling with liquefied gas must resist a test
pressure equal to at least 12 bars.
4.1.4. Filling
(a) Aerosol dispensers filled with compressed gas shall not be
required to withstand a pressure of more than 9 bars at 50ºC.
(b) Aerosol dispensers filled with dissolved gas shall not be
required to withstand a pressure of more than 8 bars at 50ºC.
(c) Aerosol dispensers containing liquefied gas or mixtures of
liquefied gas shall not be required to withstand, at 20ºC, at
pressure higher than those shown in the following table
Percentage weight of liquefied gas in
the total mixture
Total capacity
20%
50%
80%
50 to 80 ml
3.5 bars
2.8 bars
2.5 bars
< 80 to 160 ml
3.2 bars
2.5 bars
2.2 bars
< 160 to 220 ml
2.8 bars
2.1 bars
1.8 bars
AEROSOL DISPENSERS
This table shows the pressure limits permitted at 20ºC in relation to
the percentage of gas.
Pressure limits for percentages of gas not shown in the table shall be
extrapolated from it.
4.2. Unprotected glass containers
Aerosol dispensers using unprotected glass shall be filled exclusively with
liquefied or dissolved gases.
4.2.1. Capacity
The total capacity of these containers may not exceed 150 ml.
4.2.2. Test pressure of the container
The test pressure of the container must be equal to at least 12 bars.
4.2.3. Filling
(a) Aerosol dispensers filled with dissolved gas shall not be
required to withstand a pressure of more than 8 bars at 50ºC.
(b) Aerosol dispenser containing liquefied gas shall not be
required to withstand, at 20ºC, pressure in excess of those
shown down in the following table
Percentage weight of liquefied gas in
the total mixture
Total capacity
20%
50%
80%
50 to 70 ml
1.5 bar
1.5 bar
1.25 bar
< 70 to 150 ml
1.5 bar
1.5 bars
1 bar
This table shows the pressure limits permitted at 20ºC in relation to
the percentage of liquefied gas.
Pressure limits for percentages of gas not shown in the table shall be
extrapolated from it.
5. SPECIAL
PROVISION
APPLYING
TO
PLASTIC
AEROSOL
5.1. Plastic aerosol dispensers which may splinter on bursting shall be treated in
the same way as unprotected glass aerosol dispensers.
5.2. Plastic aerosol dispensers which cannot splinter on bursting shall be treated
in the same way as glass aerosol dispensers with a protective coating.
6. TESTS
6.1. Test requirements to be guaranteed by the person responsible for marketing
6.1.1. Hydraulic test on empty containers
6.1.1.1. Metal, glass or plastic aerosol dispensers must be able to
withstand a hydraulic pressure test as laid down in points
3.1.1, 4.1.3 and 4.2.2 of this Schedule.
6.1.1.2. Metal containers showing asymmetrical or major
distortions or other similar faults shall be rejected. A
slight symmetrical distortion of the base or one affecting
the profile of the upper casing shall be allowed provided
that the container passes the bursting test.
6.1.2. Bursting test for empty metal containers
The person responsible for marketing must ensure that the bursting
pressure of containers is at least 20% higher than the test pressure
laid down.
6.1.3. Dropping test for protected glass containers
The manufacturer must ensure that the containers satisfy the test
requirements laid down in point 4.1.2 of this Schedule.
6.1.4. Final inspection of filled aerosol dispensers
6.1.4.1. Aerosol dispensers shall be subject to one of the
following final test methods.
6.1.4.1.1
Hot water bath test
Each filled aerosol dispenser
shall
be
immersed in a hot water bath.
6.1.4.1.1.1
The temperature of the water
bath and the duration of the test
shall be such that the internal
pressure reaches that which
would be exerted by its contents
at a uniform temperature of
50°C.
6.1.4.1.1.2
Any aerosol dispenser showing
visible permanent distortion or a
leak must be rejected.
6.1.4.1.2
Hot final test methods
Other methods for heating the contents of
aerosol dispensers may be used if they
guarantee that the pressure and temperature
in each filled aerosol dispenser reach the
values required for the hot water bath test and
distortions and leaks are detected with same
precision as in the case of the hot water bath
test.
6.1.4.1.3
Cold final test methods
An alternative cold final test method may be
used if it is in accordance with the provisions
of an alternative method to the hot water bath
test for aerosol dispensers specified in point
6.2.4.3.2.2 of Annex A to Directive 94/55/
EC.
6.1.4.2. For aerosol dispensers the contents of which undergo a
physical or chemical transformation changing their
pressure characteristics after filling and before first use,
cold final test methods according to point 6.1.4.1.3
should be applied.
6.1.4.3. In case of test methods according to points 6.1.4.1.2 and
6.1.4.1.3
6.1.4.3.1
The test method must be approved by a
competent authority.
6.1.4.3.2
The person responsible for the marketing of
AEROSOL DISPENSERS
aerosol
dispensers
must
submit
an
application for approval to a competent
authority.
The
application
must
be
accompanied by the technical file describing
the method.
6.1.4.3.3
The person responsible for the marketing of
aerosol dispensers must, for surveillance
purposes, keep the approval of the competent
authority, the technical file describing the
method and, if applicable, control reports
readily available at the address specified on
the label in accordance with point 5.2.1 of
regulation 5.2.
6.1.4.3.4
The technical file must be established in an
official Community language or a certified
copy thereof must be available.
6.1.4.3.5
"competent authority" means the authority
designated in each Member State under
Directive 94/55/EC.
6.2. Examples of inspection tests which may be carried out by Member States
6.2.1. Test on unfilled containers
The test pressure shall be applied for 25 seconds on five containers
selected at random from a homogeneous batch of 2 500 unfilled
containers, i.e. manufactured from the same materials by the same
continuous batch manufacturing process, or from a batch
constituting one hour’s production.
If any of these containers does not pass the test, ten additional
containers shall be drawn at random from the same batch and put
through the same test.
If any one of these aerosols containers does not pass the test, the
whole batch shall be unsuitable for use.
6.2.2. Tests on filled aerosol dispensers
Air and water-tightness inspection test shall be carried out by
immersing a representative number of filled aerosol dispensers in a
bath of water. The temperature of the bath and the period of
immersion musk be such as to enable the contenks of the aerosol
dispenser to attain a uniform temperature of 50ºC during the time
required to ensure that there is no bursting or rupture.
Any batch of aerosol dispensers which does not pass these tests
must be considered unsuitable for use.
6.3. Tests on the flammability of aerosols
6.3.1. Ignition distance test for spray aerosols
6.3.1.1. Introduction
6.3.1.1.1. This test standard describes the method to
determine the ignition distance of an aerosol
spray in order to assess the associated flame
risk. The aerosol is sprayed in the direction
of an ignition source at intervals of 15 cm to
observe if ignition and sustained combustion
of the spray takes place. Ignition and
sustained combustion is defined as when a
stable flame is maintained for at least five
seconds. The ignition source is defined as a
gas burner with a blue, non-luminous flame
4-5 cm in height.
6.3.1.1.2. This test is applicable to aerosol products
with a spray distance of 15 cm or more.
Aerosol products with a spray distance of less
than 15 cm such as dispensing foams,
mousses, gels and pastes or fitted with a
metering valve, are excluded from this test.
Aerosol products that dispense foams,
mousses, gels or pastes are subject to testing
under the aerosol foam flammability test.
6.3.1.2. Apparatus and material
6.3.1.2.1. The following apparatus is required
Water bath maintained at 20°C
accurate to ± 1°C
Calibrated laboratory scales
(balance)
accurate to ± 0,1 g
Chronometer (stopwatch)
accurate to ± 0,2 s
Graduated scale, support and
clamp
graduations in cm
Gas burner with support and clamp
Thermometer
accurate to ± 1°C
Hygrometer
accurate to ± 5%
Pressure gauge
accurate to ± 0,1 bar
6.3.1.3. Procedure
6.3.1.3.1. General requirements
6.3.1.3.1.1. Before testing, each aerosol
dispenser shall be conditioned
and then primed by discharging
for approximately one second.
The purpose of this action is to
remove
non-homogeneous
material from the diptube.
6.3.1.3.1.2. The instructions of use shall be
strictly followed, including
whether the
dispenser is
intended to be used in the
upright or inverted position.
When shaking is required, shake
immediately before testing.
6.3.1.3.1.3. The test shall be carried out in a
draught-free
environment
capable of ventilation, with the
temperature controlled at 20°C
AEROSOL DISPENSERS
± 5°C and relative humidity in
the range 30-80.
6.3.1.3.1.4. Each aerosol dispenser is to be
tested
(a) when full according to the
complete procedure, with
the gas burner in the range
of 15-90 cm distance from
the actuator of the aerosol
can;
(b) when 10-12% full nominal
(% by mass) only one test,
either at 15 cm distance
from the actuator when the
spray from a full can did
not ignite at all, or at the
flame ignition distance of
the spray of a full can plus
15 cm.
6.3.1.3.1.5. During the test, the can shall be
positioned as indicated by label
instructions. The ignition source
shall be positioned accordingly.
6.3.1.3.1.6. The
following
procedure
requires testing the spray at
intervals of 15 cm between the
burner flame and the aerosol
actuator, in the range of 15-90
cm. It is efficient to start at 60
cm distance between burner
flame and aerosol actuator. The
distance between burner flame
and aerosol actuator shall be
increased by 15 cm in the case
of an ignition of the spray at 60
cm distance. The distance shall
be decreased by 15 cm in the
case of no ignition at 60 cm
distance between burner flame
and aerosol actuator. The aim of
the procedure is to determine
the maximum distance between
aerosol actuator and burner
flame that leads to sustained
combustion of the spray or to
determine that ignition could
not be obtained at 15 cm
distance between the burner
flame and the aerosol’s actuator.
6.3.1.3.2. Test procedure
(a) a minimum of 3 full aerosol dispensers
per product shall be conditioned to 20°C
± 1°C with at least 95 % of the dispenser
immersed in the water for at least 30 min
before each test (if the aerosol is fully
immersed, 30 min conditioning is
sufficient);
(b) comply with general requirements.
Record the temperature and relative
humidity of the environment;
(c) weigh an aerosol dispenser and note its
mass;
(d) determine the internal pressure and
initial discharge rate at 20°C ± 1°C (to
eliminate faulty or partly filled aerosol
dispensers);
(e) support the gas burner on a flat
horizontal surface or fix the burner to a
support by means of a clamp;
(f) ignite the gas burner; the flame shall be
non-luminous and approximately 4-5 cm
high;
(g) place the actuator’s exit orifice at the
required distance from the flame. The
aerosol shall be tested in the position it is
designed to be used, e.g. upright or
inverted;
(h) level the actuator's orifice and burner
flame, ensuring that the orifice is
properly directed towards and aligned
with the flame (see Figure 6.3.1.1). The
spray shall be expelled through the top
half of the flame;
Figure 6.3.1.1
(i) comply with the general requirements
regarding shaking of the dispenser;
(j) actuate the valve of the aerosol
dispenser, to discharge its contents for
five seconds, unless ignition occurs. If
ignition occurs, continue discharging and
time the duration of the flame for five
seconds, from the start of ignition;
(k) note the ignition results for the distance
between the gas burner and the aerosol
dispenser in the table provided;
AEROSOL DISPENSERS
(l) if no ignition occurs during step (j), the
aerosol shall be tested in alternative
orientations, e.g. inverted for upright use
products, to check if ignition is obtained;
(m) repeat steps (g) to (l) twice more (a total
of 3) for the same can at the same
distance between the gas burner and the
aerosol actuator;
(n) repeat the test procedure for another two
aerosol cans of the same product at the
same distance between gas burner and
aerosol actuator;
(o) repeat steps (g) to (n) of the test
procedure at a distance between 15 and
90 cm between the actuator of the aerosol
can and the burner flame depending on
the outcome of each test (see also
6.3.1.3.1.4 and 6.3.1.3.1.5);
(p) if no ignition occurs at 15 cm, the
procedure is finished for initially full
cans. The procedure is also finished
when ignition and sustained combustion
is obtained at a distance of 90 cm. If
ignition could not be obtained at 15 cm
distance, record that ignition did not
occur. The maximum distance between
burner flame and the aerosol’s actuator
for which an ignition and sustained
combustion was observed is noted as the
"ignition distance", in all other
circumstances;
(q) one test shall also be conducted on three
cans of 10-12% nominal fill level. These
cans shall be tested at a distance between
the aerosol’s actuator and the burner
flame of the ‘flame ignition distance of
full cans + 15 cm’;
(r) discharge an aerosol can to a 10-12%
nominal fill level (by mass) in bursts of
30 seconds maximum. Observe a 300
seconds minimum time period between
bursts. During this interim period
dispensers shall be placed in the water
bath for conditioning;
(s) repeat steps (g) to (n) for 10-12%
nominal fill aerosol cans, omitting steps
(l) and (m). This test shall only be
performed with the aerosol in one
position, e.g. upright or inverted,
corresponding with that which produced
the ignition (if any) for filled cans; and
(t) record all results in the Table 6.3.1.1 as
shown below.
6.3.1.3.2.1. All
experiments
shall
be
performed in a fume hood in a
room that may be well
ventilated. Ventilation of the
fume hood and room can be
applied for at least three minutes
after each test. Take all
necessary safety precautions to
prevent
the
inhalation
of
combustion products.
6.3.1.3.2.2. The cans with a 10-12% nominal
fill level shall be tested only
once. The result tables need only
one result per can indicated.
6.3.1.3.2.3. When the test in the position in
which the dispenser is designed
to be used gives a negative
result, the test shall be repeated
in the position of the dispenser
most likely to result in a positive
result.
6.3.1.4. Method of assessing results
6.3.1.4.1
All the results shall be recorded. Table
6.3.1.1 below shows the model of ‘result
table’ to be used.
Table 6.3.1.1
Date
Temperature .............. °C
Relevant humidity ....... %
Name of product
Net volume
Can 1
Can 2
Can 3
Initial level
of filling
D i s p e n s e r Test
1 2 3
distance
15 cm
Ignition?
Y or N
30 cm
Ignition?
Y or N
45 cm
Ignition?
Y or N
60 cm
Ignition?
Y or N
75 cm
Ignition?
Y or N
90 cm
Ignition?
Y or N
AEROSOL DISPENSERS
Observa-
tions
-
including
can
position
6.3.2. Enclosed space ignition test
6.3.2.1. Introduction
This test standard describes the method to assess the
flammability of products emerging from aerosol
dispensers due to their propensity to ignite in an enclosed
or confined space. The contents of an aerosol dispenser
are sprayed into a cylindrical test vessel containing a
burning candle. If an observable ignition occurs, the
elapsed time and amount discharged is noted.
6.3.2.2. Apparatus and material
6.3.2.2.1
The following apparatus is required
Chronometer (stopwatch)
accurate to ± 0,2 s
Water bath maintained at 20°C
accurate to ± 1°C
Calibrated laboratory scales
(balance)
accurate to ± 0,1 g
Thermometer
accurate to ± 1°C
Hygrometer
accurate to ± 5%
Pressure gauge bar
accurate to ± 0,1
Cylindrical test vessel
as detailed below
6.3.2.2.2
Preparation of test apparatus
6.3.2.2.2.1. A
cylindrical
vessel
approximately 200 dm3 volume,
approximately 600 mm in
diameter and approximately 720
mm long and open at one end
shall be modified as follows
6.3.2.2.2.1.1 a closure system
consisting of a
hinged cover shall
be matched to the
open end of the
receptacle; or
6.3.2.2.2.1.2 a plastic film 0,01
to 0,02 mm thick
may be used as a
closure system. If
the test is carried
out with a plastic
film this must be
used as described
below
Stretch the film
over the open end
of the drum and
hold it in place
with an elastic
band.
The
strength of the
band shall be such
that when placed
around the drum
resting on its side,
it stretches by
only 25 mm when
a mass of 0,45 kg
is attached to its
lowest point. Cut
a 25 mm slit in
the film, starting
50 mm from the
edge of the drum.
Ensure that the
film is taut; or
6.3.2.2.2.1.3 at the other end of
the drum drill a
50 mm diameter
hole 100 mm
from the edge in
such a way that
the
orifice
is
uppermost when
the receptacle is
laid down and
ready for the test
(Figure 6.3.2.1.)
Figure 6.3.2.1
6.3.2.2.2.1.4 on a 200 200
mm metal support
place a paraffin
wax candle 20 to
mm
in
diameter and 100
mm high. The
candle shall be
replaced
when
having a height of
less than 80 mm.
The
candle's
flame is protected
AEROSOL DISPENSERS
from the action of
the spray by a 150
mm wide, 200
mm
high
deflector.
This
includes the plane
inclined at 45°
produced 150 mm
from the base of
the
deflector
(Figure 6.3.2.2.);
Figure 6.3.2.2
6.3.2.2.2.1.5 the candle placed
on
the
metal
support shall be
positioned
midway between
the two ends of
the drum (Figure
6.3.2.3);
Figure 6.3.2.3
6.3.2.2.2.1.6 the drum is laid
on the ground or
on a support at a
spot where the
temperature
is
between 15°C and
25°C.
The
product to be
tested will be
sprayed
within
the
drum
of
roughly 200 dm3
in which there
will be a source of
ignition.
6.3.2.2.2.2. Usually, the product leaves the
aerosol can at an angle of 90°
relevant to the vertical axis of
the can. The layout and
procedure described refers to
this kind of aerosol product. In
the case of unusually operating
aerosols (e.g. vertical-spray
aerosol dispensers) it will be
necessary to record changes to
equipment and procedures in
accordance with good laboratory
practice, such as ISO/IEC
17025:1999
General
requirements for the competence
of testing and calibration
laboratories.
6.3.2.3. Procedure
6.3.2.3.1. General requirements
6.3.2.3.1.1. Before testing, each aerosol
dispenser shall be conditioned
and then primed by discharging
for approximately 1 second. The
purpose of this action is to
remove
non-homogeneous
material from the diptube.
6.3.2.3.1.2. The instructions of use shall be
strictly
followed,
including
whether
the
dispenser
is
intended to be used in the
upright or inverted position.
When shaking is required, shake
immediately before testing.
6.3.2.3.1.3. The tests shall be carried out in a
draught-free
environment
capable of ventilation, with the
temperature controlled at 20°C ±
5°C and relative humidity in the
range 30-80%.
6.3.2.3.2. Test procedure
6.3.2.3.2.1 a minimum of 3 full aerosol
dispensers per product shall be
conditioned to 20°C ± 1°C in a
water bath with at least 95% of
the dispenser immersed in the
water for at least 30 min (if the
aerosol is fully immersed, 30
min conditioning is sufficient);
6.3.2.3.2.2 measure or calculate the actual
volume of the drum in dm3;
AEROSOL DISPENSERS
6.3.2.3.2.3 comply
with
general
requirements.
Record
the
temperature
and
relative
humidity of the environment;
6.3.2.3.2.4 determine the internal pressure
and initial discharge rate at 20°C
± 1°C (to eliminate faulty or
partly filled aerosol dispensers);
6.3.2.3.2.5 weigh one of the aerosol
dispensers and note its mass;
6.3.2.3.2.6 light the candle and apply the
closure system (cover or plastic
film);
6.3.2.3.2.7 place the aerosol dispenser
actuator orifice 35 mm or closer
for a wide spray product, from
the centre of the entrance hole in
the drum. Start the chronometer
(stopwatch) and following the
instructions for use of the
product; direct the spray towards
the centre of the opposite
extremity (cover or plastic film).
The aerosol shall be tested in the
position it is designed to be
used, e.g. upright or inverted;
6.3.2.3.2.8 spray until ignition occurs. Stop
the chronometer and note the
time elapsed. Re-weigh the
aerosol dispenser and note its
mass;
6.3.2.3.2.9 ventilate and clean the drum
removing any residue likely to
affect subsequent tests. Allow
the drum to cool if necessary;
and
6.3.2.3.2.10 repeat the test procedure steps
6.3.2.3.2.4 to 6.3.2.3.2.9 for
another two aerosol dispensers
of the same product (three in
total, note: each dispenser is
only tested once);
6.3.2.4. Method of assessing results
6.3.2.4.1. A test report containing the following
information shall be drawn up
6.3.2.4.1.1 the product
tested
and
its
references;
6.3.2.4.1.2 the internal
pressure and
discharge rate of the aerosol
dispenser;
6.3.2.4.1.3 the temperature and relative air
humidity of the room;
6.3.2.4.1.4 for each test, the discharge
time(s) needed to achieve
ignition (if the product does not
ignite, state this);
6.3.2.4.1.5 the mass of the product sprayed
during each test (in g);
6.3.2.4.1.6 the actual volume of the drum
(in dm3).
6.3.2.4.2. The time equivalent (teq) needed to achieve
ignition in one cubic metre can be calculated
as follows
1 000 discharge time(s)
teq =
Actual volume of drum (dm 3 )
6.3.2.4.3
The deflagration density (Ddef) needed to
achieve ignition during the test may also be
calculated as follows
1 000 Amount of product dispensed
Ddef =
Actual volume of drum (dm 3 )
6.3.3. Aerosol foam flammability test
6.3.3.1. Introduction
6.3.3.1.1. This test standard describes the method to
determine the flammability of an aerosol
spray emitted in the form of a foam, mousse,
gel or paste. An aerosol, which emits a foam,
mousse,
gel
or
paste
is
sprayed
(approximately 5 g) on a watchglass and an
ignition source (candle, wax taper, match or
lighter) is placed at the base of the
watchglass to observe if ignition and
sustained combustion of the foam, mousse,
gel or paste occurs. Ignition is defined as a
stable flame maintained for at least two
seconds and a minimum 4 cm in height.
6.3.3.2. Apparatus and material
6.3.3.2.1. The following apparatus is required
Graduated scale, support and clamp gradations in cm
Fire-resistant watchglass roughly 150 mm in diameter
Chronometer (stopwatch)
accurate to ± 0,2 s
Candle, wax taper, match or lighter
Calibrated laboratory scales
(balance)
accurate to ± 0,1 g
Water bath maintained at 20°C
accurate to ± 1°C
Thermometer
accurate to ± 1°C
Hygrometer
accurate to ± 5%
AEROSOL DISPENSERS
Pressure gauge bar
accurate to ± 0,1
6.3.3.2.2. The watchglass is placed on a fire-resistant
surface within a draught-free area that may
be ventilated after each test. The graduated
scale is positioned exactly behind the
watchglass and held vertically by means of a
support and clamp.
6.3.3.2.3. The scale is positioned in such a way that its
origin is on a level with the watchglass base
in a horizontal plane.
6.3.3.3. Procedure
6.3.3.3.1. General requirements
6.3.3.3.1.1. Before testing, each aerosol
dispenser shall be conditioned
and then primed by discharging
for approximately 1 second. The
purpose of this action is to
remove
non-homogeneous
material from the diptube.
6.3.3.3.1.2. The instructions of use shall be
strictly
followed,
including
whether
the
dispenser
is
intended to be used in the
upright or inverted position.
When shaking is required, shake
immediately before testing.
6.3.3.3.1.3. The tests shall be carried out in a
draught-free
environment
capable of ventilation, with the
temperature controlled at 20°C ±
5°C and relative humidity in the
range of 30-80%.
6.3.3.3.2
Test procedure
6.3.3.3.2.1 a minimum of four full aerosol
dispensers per product shall be
conditioned to 20°C ± 1°C with
at least 95% of the dispenser
immersed in the water for at
least 30 min before each test (if
the aerosol is fully immersed, 30
min conditioning is sufficient);
6.3.3.3.2.2 comply
with
general
requirements.
Record
the
temperature
and
relative
humidity of the environment;
6.3.3.3.2.3 determine the internal pressure
at 20°C ± 1°C (to eliminate
faulty or partly filled aerosol
dispensers);
6.3.3.3.2.4 measure the discharge or flow
rate of the aerosol product to be
examined, so that the amount of
test product dispensed can be
more accurately gauged;
6.3.3.3.2.5 weigh one of the aerosol
dispensers and note its mass;
6.3.3.3.2.6 on the basis of the measured
discharge or flow rate and
following the manufacturer’s
instructions,
release
approximately 5 g of the product
onto the centre of the clean
watchglass with the aim of
producing a mound no higher
than 25 mm;
6.3.3.3.2.7 within
five
seconds
of
completion of discharge, apply
the source of ignition to the edge
of the sample at its base and at
the same time start the
chronometer (stopwatch). If
necessary, the ignition source
shall be removed from the edge
of
the
sample
after
approximately two seconds, in
order to clearly observe if
ignition has occurred. If no
ignition of the sample is
apparent, the ignition source
shall be reapplied to the edge of
the sample;
6.3.3.3.2.8 if ignition occurs
note
the
following points
6.3.3.3.2.8.1 the
maximum
height
of
the
flame in cm above
the base of the
watchglass;
6.3.3.3.2.8.2 the
flame
duration in s; and
6.3.3.3.2.8.3 dry and re-weigh
the
aerosol
dispenser
and
calculate the mass
of the released
product;
6.3.3.3.2.9
ventilate the test
area immediately
after each test;
6.3.3.3.2.10
if ignition is not
obtained and the
AEROSOL DISPENSERS
released product
remains in the
form of a foam or
paste throughout
its period of use,
steps (e) to (i)
shall be repeated.
Allow the product
to stand for 30
sec, 1 min, 2 min
or 4 min before
applying
the
ignition source;
6.3.3.3.2.11
repeat the test
procedure steps
(e) to (j) twice
more (a total of 3)
for the same can;
and
6.3.3.3.2.12
repeat the test
procedure steps
(e) to (k) for
another
two
aerosol cans (3
cans in total) of
the same product.
6.3.3.4. Method of assessing results
6.3.3.4.1. A test report containing the following
information shall be drawn up
6.3.3.4.1.1 whether the product ignites;
6.3.3.4.1.2 maximum flame height in cm;
6.3.3.4.1.3 duration of flame in s; and if
6.3.3.4.1.4 the mass of the product was
tested.
1. These regulations shall apply to aerosol dispensers as
d efin ed in reg ulatio n 3 , wit h th e ex ceptio n o f th os e with a
maximum capacity of less than 50 ml, and those with a maximum
capacity greater than that specified in points 3.1, 4.1.1, 4.2.1, 5.1
and 5.2 respectively of the Annex of the Directive, which is set out
in the Schedule.
2.2. These regulations implement the provisions of Commission
Directive 2013/10/EU of 19 March 2013 amending Council Directive
75/324/EEC on the approximation of the laws of the Member States
relating to aerosol dispensers in order to adapt its labelling provisions
to Regulation (EC) No 1272/2008 of the European Parliament and of
the Council on classification, labelling and packaging of substances
and mixtures.
2.3 These regulations transpose Commission Directive 2016/2037
of 21 November 2016 amending Council Directive 75/324/EEC as
regards the maximum allowable pressure of aerosol dispensers and to
adapt its labelling provisions to Regulation (EC) No 1272/2008 of the
European Parliament and of the Council on classification, labelling and
packaging of substances and mixtures."
1. For the purposes of these regulations, the following
definitions shall apply
3.1.1.
"the Directive" means Council Directive 75/324/
EEC on the approximation of the laws of the
Member States relating to aerosol dispensers, as
amended by Commission Directive 94/01/EEC;
3.1.2.
"aerosol dispenser" means any non-reusable
container made of metal, glass or plastic and
containing a gas compressed, liquefied or
dissolved under pressure, with or without a liquid,
*see also regulation 1(3), (4), (5) and (6) of Legal Notice 395 of 2013 for the
applicability of the amendments made by the said legal notice as regards aerosol
dispensers containing a substance, aerosol dispensers containing mixtures and the
labelling of aerosol containers containing mixtures.
AEROSOL DISPENSERS
paste or powder, and fitted with a release device
allowing the contents to be ejected as solid or
liquid particles in suspension in a gas, as a foam,
paste or powder or in a liquid state;
3.1.3.
"OJ" means the Official Journal of the European
Communities;
3.1.4.
"manufacturer" means the person who is primarily
responsible for the design and construction of the
aerosol dispenser so that it complies with the
requirements of these regulations;
3.1.5.
"local authorised representative" means any
person (or organisation) established in Malta who
has been appointed by the manufacturer to act on
his behalf in carrying out certain tasks required by
these regulations;
3.1.6.
"importer" means any person who places aerosol
dispensers from a foreign country on to the
Maltese market so that he supplies such aerosol
dispensers on the first occasion that they are
supplied in Malta;
3.1.7.
"person who supplies aerosol dispensers" means
wholesalers, distributors, retailers, etc;
3.1.8.
"supply" includes offering to supply, agreeing to
supply, exposing for supply and possessing for
supply, and cognate expressions shall be construed
accordingly;
3.1.9.
"responsible person"
in
relation
to
aerosol
dispensers means
3.1.9.1.
the manufacturer thereof;
3.1.9.2.
the manufacturer’s local authorised
representative; or
3.1.9.3.
where the manufacturer is not
established in Malta and he has not
appointed
a
local
authorised
representative, the person who places
the aerosol dispensers on the local
market.
3.1.10.
"placing on the market" means importation
wholesale, retail, sale and distribution free of
charge.
1. The provisions of these regulations are applicable to all
imported aerosol dispensers as well as to those manufactured for
the local market.
4.1.1.
No person may construct, import, place on the
market or put into service any aerosol dispensers
which do not comply with the provisions of these
regulations.
AEROSOL DISPENSERS
1. The responsible person shall affix the symbol ‘3’ (inverted
epsilon) to aerosol dispensers, as proof that they satisfy the
requirements of these regulations and the Schedule.
5.2. Without prejudice to Regulation (EC) No 1272/2008 of the
European Parliament and of the Council, each aerosol dispenser or,
where particulars cannot be put on the aerosol dispenser due to its
small dimensions (maximum capacity of 150 ml or less) a label
attached thereto must bear the following particulars in visible, legible
and indelible characters
5.2.1.
the name and address or trade mark of the person
responsible for marketing the aerosol dispenser,
5.2.2.
the symbol ‘3’ (inverted epsilon) certifying
conformity with the requirements of these
regulations,
5.2.3.
code and markings enabling the filling batch to be
identified,
5.2.4.
the details referred to in point 2.2 of the Schedule,
5.2.5.
the net contents by weight and by volume,
5.2.6.
Where an aerosol dispenser contains flammable
components as defined in point 1.8 of the
Schedule but the aerosol dispenser is not
considered as "flammable" or "extremely
flammable" according to the criteria set out in
point 1.9 of the Schedule, the quantity of
flammable material contained in the aerosol
dispenser must be stated clearly on the label, in
the form of the following legible and indelible
wording: "X % by mass of the contents are
flammable".
5.3. The wording on the label of aerosol dispensers being
placed on the local market should be made in either the Maltese or
the English language.
5.4. All necessary measures shall be taken to prevent the use on
aerosol dispensers of markings or inscriptions which might be
confused with the symbol ‘3’ (inverted epsilon).
1. The marketing of any aerosol dispenser which complies
with the requirements of these regulations may not, for reasons
related to the requirements laid down in these regulations and the
Annex of the Directive, which is set out in the Schedule, be
refused, prohibited or restricted.
1. All appropriate measures shall be taken to encourage the
local authorities responsible for implementing these regulations to
cooperate with each other and provide each other with information
in order to assist the functioning of these regulations.
7.2. If the Director General of Technical Regulations Division
notes, on the basis of a substantive justification, that one or more
aerosol dispensers, although complying with the requirements of
these regulations, represent a hazard to safety or health, it may
provisionally prohibit the sale of the dispenser or dispensers in
AEROSOL DISPENSERS
Malta or subject it or them to special conditions.
7.2.1.
Such a decision shall be notified as soon as
possible to the party concerned, who shall at the
same time be informed of the legal remedies
available to him under the laws in force in Malta
and of the time limits to which such remedies are
subject.
7.2.2.
Deleted by Legal Notice 93 of 2017.
7.3. The Technical Regulations Division of the Malta Competition
and Consumer Affairs Authority shall immediately inform the
Commission and the other Member States of any measures taken in
pursuance of regulation 7.2.