WORK PLACE (MINIMUM HEALTH AND SAFETY REQUIREMENTS FOR THE PROTECTION OF WORKERS FROM RISKS RESULTING FROM
Table of Provisions (15)
Statutory Text (15 Articles)
SUBSIDIARY LEGISLATION 424.34
WORK PLACE (MINIMUM HEALTH AND SAFETY
REQUIREMENTS FOR THE PROTECTION OF
WORKERS FROM RISKS RESULTING FROM
EXPOSURE TO ELECTROMAGNETIC FIELDS)
REGULATIONS *
1st July, 2016 †
LEGAL NOTICE 257 of 2016, as amended by Act XXXIII of 2024.
(1) The title of these regulations is the Work Place
(Minimum Health and Safety Requirements for the Protection of
Workers from Risks resulting from Exposure to Electromagnetic
Fields) Regulations.
(2) The scope of these regulations is to lay down minimum
requirements for the protection of workers from risks to their health
and safety arising, or likely to arise, from exposure to
electromagnetic fields during their work. These regulations shall
implement Directive 2013/35/EC of the European Parliament and
of the Council. These regulations cover all known direct
biophysical effects and indirect effects caused by electromagnetic
fields.
(3) The exposure limit values (ELVs) laid down in these
regulations cover only scientifically well-established links between
short-term direct biophysical effects and exposure to
electromagnetic fields.
(4)
These regulations do not cover suggested long-term
effects.
(5) These regulations do not cover the risks resulting from
contact with live conductors.
(6) These regulations shall apply fully to all workers without
prejudice to more stringent and, or more specific provisions
contained in any other law or regulation on the protection of
workers from the risks related to exposure to electromagnetic
fields.
PHYSICAL QUANTITIES REGARDING THE EXPOSURE
TO ELECTROMAGNETIC FIELDS
T h e f o l l o w i n g p h y s i c a l q u a n t i t i e s ar e u s e d t o d e s c r i b e t h e e x p o s u r e t o
electromagnetic fields
Electric field strength (E) is a vector quantity that corresponds to the force exerted
on a charged particle regardless of its motion in space. It is expressed in volt per metre
(Vm -1 ). A distinction has to be made between the environmental electric field and the
electric field present in the body (in situ) as a result of exposure to the
environmental electric field.
Limb current (I L ) is the current in the limbs of a person exposed to
electromagnetic fields in the frequency range from 10 MHz to 110 MHz as a result of
contact with an object in an electromagnetic field or the flow of capacitive currents
induced in the exposed body. It is expressed in ampere (A).
Contact current (I C ) is a current that appears when a person comes into contact
with an object in an electromagnetic field. It is expressed in ampere (A). A steady
state contact current occurs when a person is in continuous contact with an object in
an electromagnetic field. In the process of making such contact, a spark discharge
may occur with associated transient currents.
Electric charge (Q) is an appropriate quantity used for spark discharge and is
expressed in coulomb (C).
Magnetic field strength (H) is a vector quantity that, together with the magnetic flux
density, specifies a magnetic field at any point in space. It is expressed in ampere per
metre (Am -1 ).
Magnetic flux density (B) is a vector quantity resulting in a force that acts on
moving charges, expressed in tesla (T). In free space and in biological materials,
magnetic flux density and magnetic field strength can be interchanged using the
magnetic field strength of H = 1 Am -1 equivalence to magnetic flux density of B =
4π 10 -7 T (approximately 1.25 microtesla).
Power density (S) is an appropriate quantity used for very high frequencies, where
the depth of penetration in the body is low. It is the radiant power incident
perpendicular to a surface, divided by the area of the surface. It is expressed in watt
per square metre (Wm -2 ).
Specific energy absorption (SA) is an energy absorbed per unit mass of biological
tissue, expressed in joule per kilogram (Jkg -1 ). In these regulations, it is used for
establishing limits for effects from pulsed microwave radiation.
Specific energy absorption rate (SAR), averaged over the whole body or over parts
of the body, is the rate at which energy is absorbed per unit mass of body tissue and is
expressed in watt per kilogram (Wkg -1 ). Whole-body SAR is a widely accepted
quantity for relating adverse thermal effects to radio frequency (RF) exposure.
Besides the whole-body average SAR, local SAR values are necessary to evaluate and
limit excessive energy deposition in small parts of the body resulting from special
exposure conditions. Examples of such conditions include: an individual exposed to
RF in the low MHz range (e.g. from dielectric heaters) and individuals exposed in
the near field of an antenna.
Of these quantities, magnetic flux density (B), contact current (I C ), limb current
(I L ), electric field strength (E), magnetic field strength (H), and power density (S)
can be measured directly.
In these regulations, unless the context otherwise requires -
"Act" means the Health and Safety at Work Act;
"action levels (ALs)" means operational levels established for
the purpose of simplifying the process of demonstrating the
compliance with relevant ELVs or, where appropriate, to take
relevant protection or prevention measures specified in these
*These regulations have been transferred to Cap. 646. Vide S.L. 646.23 and Act
XXXIII of 2024.
† see regulation 1(7) of these Regulations as originally promulgated.
regulations.
The Action Level terminology used in Schedule II is as follows
(a) for electric fields, "low ALs" and "high ALs" means
levels which relate to the specific protection or
prevention measures specified in these regulations;
and
(b) for magnetic fields, "low ALs" means levels which
relate to the sensory effects ELVs and "high ALs" to
the health effects ELVs;
"Authority" means the Occupational Health and Safety Authority
established by article 4 of the Act;
"Commission" means the Commission of the European Union;
"direct biophysical effects" means effects in the human body
directly caused by its presence in an electromagnetic field,
including
(a) thermal effects, such as tissue heating through energy
absorption from electromagnetic fields in the tissue;
(b) non-thermal effects, such as the stimulation of
muscles, nerves or sensory organs. These effects might
have a detrimental effect on the mental and physical
health of exposed workers. Moreover, the stimulation
of sensory organs may lead to transient symptoms,
such as vertigo or phosphenes. These effects might
create temporary annoyance or affect cognition or
other brain or muscle functions, and may thereby
affect the ability of a worker to work safely (i.e. safety
risks); and
(c) limb currents;
"electromagnetic fields" means static electric, static magnetic
and time-varying electric, magnetic and electromagnetic fields with
frequencies up to 300 GHz;
"exposure limit values (ELVs)" means values established on the
basis of biophysical and biological considerations, in particular on
the basis of scientifically well-established short-term and acute
direct effects, i.e. thermal effects and electrical stimulation of
tissues;
"health effects ELVs" means those ELVs above which workers
might be subject to adverse health effects, such as thermal heating
or stimulation of nerve and muscle tissue;
"indirect effects" means effects, caused by the presence of an
object in an electromagnetic field, which may become the cause of
a safety or health hazard, such as
(a) interference with medical electronic equipment and
devices, including cardiac pacemakers and other
implants or medical devices worn on the body;
(b) the projectile risk from ferromagnetic objects in static
magnetic fields;
(c) the initiation of electro-explosive devices (detonators);
(d) fires and explosions resulting from the ignition of
flammable materials by sparks caused by induced
fields, contact currents or spark discharges; and
(e) contact currents;
"sensory effects ELVs" means those ELVs above which workers
might be subject to transient disturbed sensory perceptions and
minor changes in brain functions;
"Union" means the European Union.
NON-THERMAL EFFECTS
EXPOSURE LIMIT VALUES AND ACTION LEVELS IN THE FREQUENCY
RANGE FROM 0 Hz TO 10 MHz
PART A.
EXPOSURE LIMIT VALUES (ELVs)
ELVs below 1 Hz (Table A1) are limits for static magnetic field which is not
affected by the tissue of the body.
ELVs for frequencies from 1 Hz to 10 MHz (Table A2) are limits for electric fields
induced in the body from exposure to time-varying electric and magnetic fields.
ELVs for external magnetic flux density from 0 to 1 Hz
The sensory effects ELV is the ELV for normal working conditions (Table A1) and
is related to vertigo and other physiological effects related to disturbance of the
human balance organ resulting mainly from moving in a static magnetic field.
The health effects ELV for controlled working conditions (Table A1) is applicable
on a temporary basis during the shift when justified by the practice or process,
provided that preventive measures, such as controlling movements and providing
information to workers, have been adopted.
Table A1
ELVs for external magnetic flux density (B 0 ) from 0 to 1 Hz
Sensory effects ELVs
Normal working conditions
2 T
Localised limbs exposure
8 T
Health effects ELVs
Controlled working conditions
8 T
Health effects ELVs for internal electric field strength from 1 Hz to 10 MHz
Health effects ELVs (Table A2) are related to electric stimulation of all peripheral
and central nervous system tissues in the body, including the head.
Table A2
Health effects ELVs for internal electric field strength from 1 Hz to 10 MHz
Frequency range
Health effects ELVs
1.1 Vm -1 (peak)
1 Hz ≤ f < 3 kHz
3.8 × 10 -4 f Vm -1 (peak)
3 kHz ≤ f ≤ 10 MHz
Note A2-1: f is the frequency expressed in hertz (Hz).
Note A2-2: The health effects ELVs for internal electric field are spatial peak
values in the entire body of the exposed subject.
Note A2-3: The ELVs are peak values in time which are equal to the Root-Mean-
Square (RMS) values multiplied by √2 for sinusoidal fields. In the case of non-
sinusoidal fields, exposure evaluation carried out in accordance with regulation 4
shall be based on the weighted peak method (filtering in time domain), explained in
the practical guides made available by the Commission but other scientifically proven
and validated exposure evaluation procedures can be applied, provided that they lead
to approximately equivalent and comparable results.
Sensory effects ELVs for internal electric field strength from 1 Hz to 400 Hz
The sensory effects ELVs (Table A3) are related to electric field effects on the
central nervous system in the head, i.e. retinal phosphenes and minor transient
changes in some brain functions.
Table A3
Sensory effects ELVs for internal electric field strength
from 1 to 400 Hz
Frequency range
Sensory effects ELVs
0.7/f Vm -1 (peak)
1 ≤ f < 10 Hz
0.07 Vm -1 (peak)
10 ≤ f < 25 Hz
0.0028 f Vm -1 (peak)
25 ≤ f ≤ 400 Hz
Note A3-1: f is the frequency expressed in hertz (Hz).
Note A3-2: The sensory effects ELVs for internal electric field are spatial peak
values in the head of the exposed subject.
Note A3-3: The ELVs are peak values in time which are equal to the Root-Mean-
Square (RMS) values multiplied by √2 for sinusoidal fields. In the case of non-
sinusoidal fields, the exposure evaluation carried out in accordance with regulation 4
shall be based on the weighted peak method (filtering in time domain), explained in
the practical guides made available by the Commission, but other scientifically
proven and validated exposure evaluation procedures can be applied, provided that
they lead to approximately equivalent and comparable results.
PART B. ACTION LEVELS (ALs)
The following physical quantities and values are used to specify the action levels
(ALs), the magnitude of which are established to ensure by simplified assessment the
compliance with relevant ELVs or at which relevant protection or prevention
measures specified in regulation 5 must be taken
-
Low ALs(E) and high ALs(E) for electric field strength E of time
varying electric fields as specified in Table B1;
-
Low ALs(B) and high ALs(B) for magnetic flux density B of time
varying magnetic fields as specified in Table B2;
-
ALs(I C ) for contact current as specified in Table B3;
-
ALs(B 0 ) for magnetic flux density of static magnetic fields as
specified in Table B4.
ALs correspond to calculated or measured electric and magnetic field values at the
workplace in the absence of the worker.
Action levels (ALs) for exposure to electric fields
Low ALs (Table B1) for external electric field are based on limiting the internal
electric field below the ELVs (Tables A2 and A3) and limiting spark discharges in the
working environment.
Below high ALs, the internal electric field does not exceed the ELVs (Tables A2 and
A3) and annoying spark discharges are prevented, provided that the protection
measures referred to in regulation 5(6) are taken.
Table B1
ALs for exposure to electric fields from 1 Hz to 10 MHz
Frequency range
Electric field strength Low Electric field strength High
ALs (E)[Vm -1 ] (RMS)
ALs (E) [Vm -1 ] (RMS)
2.0 × 10 4
2.0 × 10 4
1 ≤ f < 25 Hz
5.0 × 10 5 /f
2.0 × 10 4
25 ≤ f < 50 Hz
5.0 × 10 5 /f
1.0 × 10 6 /f
50 Hz ≤ f < 1.64 kHz
5.0 × 10 5 /f
6.1 × 10 2
1.64 ≤ f < 3 kHz
1.7 × 10 2
6.1 × 10 2
3 kHz ≤ f ≤ 10 MHz
Note B1-1: f is the frequency expressed in hertz (Hz).
Note B1-2: The low ALs (E) and high ALs (E) are the Root-Mean-Square (RMS)
values of the electric field strength which are equal to the peak values divided by √2
for sinusoidal fields. In the case of non-sinusoidal fields, the exposure evaluation
carried out in accordance with regulation 4 shall be based on the weighted peak
method (filtering in time domain), explained in the practical guides made available
by the Commission, but other scientifically proven and validated exposure evaluation
procedures can be applied, provided that they lead to approximately equivalent and
comparable results.
Note B1-3: ALs represent maximum calculated or measured values at the workers’
body position. This results in a conservative exposure assessment and automatic
compliance with ELVs in all non-uniform exposure conditions. In order to simplify
the assessment of compliance with ELVs, carried out in accordance with regulation
4, in specific non-uniform conditions, criteria for the spatial averaging of measured
fields based on established dosimetry laid down in the practical guides made available
by the Commission. In the case of a very localised source within a distance of a few
c e n t i m e t r e s f r o m t h e b o d y, t h e i n d u c e d e l e c t r i c f i e l d s h a l l b e d e t e r m i n e d
dosimetrically, case by case.
Action levels (ALs) for exposure to magnetic fields
Low ALs (Table B2) are, for frequencies below 400 Hz, derived from the sensory
effects ELVs (Table A3) and, for frequencies above 400 Hz, from the health effects
ELVs for internal electric field (Table A2).
High ALs (Table B2) are derived from the health effects ELVs for internal electric
field related to electric stimulation of peripheral and autonomous nerve tissues in
head and trunk (Table A2). Compliance with the high ALs ensures that health effects
ELVs are not exceeded, but the effects related to retinal phosphenes and minor
transient changes in brain activity are possible, if the exposure of the head exceeds
the low ALs for exposures up to 400 Hz. In such a case, regulation 5(6) applies.
ALs for exposure of limbs are derived from the health effects ELVs for internal
electric field related to electric stimulation of the tissues in limbs by taking into
account that the magnetic field is coupled more weakly to the limbs than to the
whole body.
Table B2
ALs for exposure to magnetic fields from 1 Hz to 10 MHz
Frequency range
Magnetic flux
Magnetic flux
Magnetic flux
density Low
density High
density ALs for
ALs(B)[μT]
ALs(B) [μT]
exposure of limbs
(RMS)
(RMS)
to a localised
magnetic field
[μT] (RMS)
2.0 × 10 5 /f 2
3.0 × 10 5 /f
9.0 × 10 5 /f
1 ≤ f < 8 Hz
2.5 × 10 4 /f
3.0 × 10 5 /f
9.0 × 10 5 /f
8 ≤ f < 25 Hz
1.0 × 10 3
3.0 × 10 5 /f
9.0 × 10 5 /f
25 ≤ f < 300 Hz
3.0 × 10 5 /f
3.0 × 10 5 /f
9.0 × 10 5 /f
300 Hz ≤ f < 3 kHz
1.0 × 10 2
1.0 × 10 2
3.0 × 10 2
3 kHz ≤ f ≤ 10 MHz
Note B2-1: f is the frequency expressed in hertz (Hz).
Note B2-2: The low ALs and the high ALs are the Root-Mean-Square (RMS) values
which are equal to the peak values divided by √2 for sinusoidal fields. In the case of
non-sinusoidal fields the exposure evaluation carried out in accordance with
regulation 4 shall be based on the weighted peak method (filtering in time domain),
explained in the practical guides made available by the Commission, but other
scientifically proven and validated exposure evaluation procedures can be applied,
provided that they lead to approximately equivalent and comparable results.
Note B2-3: ALs for exposure to magnetic fields represent maximum values at the
workers’ body position. This results in a conservative exposure assessment and
automatic compliance with ELVs in all non-uniform exposure conditions. In order to
simplify the assessment of compliance with ELVs, carried out in accordance with
regulation 4, in specific non-uniform conditions, criteria for the spatial averaging of
measured fields based on established dosimetry laid down in the practical guides
made available by the Commission. In the case of a very localised source within a
distance of a few centimetres from the body, the induced electric field shall be
determined dosimetrically, case by case.
Table B3
ALs for contact current I C
Frequency
ALs (I C ) steady state contact current
[mA] (RMS)
up to 2.5 kHz
1.0
2.5 ≤ f < 100 kHz
0.4 f
100 ≤ f ≤ 10 000 kHz
Note B3-1: f is the frequency expressed in kilohertz (kHz).
Action levels (ALs) for magnetic flux density of static magnetic fields
Table B4
ALs for magnetic flux density of static magnetic fields
Hazards
ALs(B 0 )
Interference with active implanted devices,
0.5 mT
e.g. cardiac pacemakers
Attraction and projectile risk in the fringe field
3 mT
of high field strength sources (> 100 mT)
(1) Physical
quantities
regarding
exposure
to
electromagnetic fields are indicated in Schedule I. Health effects
ELVs, sensory effects ELVs and ALs are set out in Schedules II and
III.
(2) Employers shall ensure that the exposure of workers to
electromagnetic fields is limited to the health effects ELVs and
sensory effects ELVs set out in Schedule II, for non-thermal
effects, and in Schedule III, for thermal effects. Compliance with
health effects ELVs and sensory effects ELVs must be established
by the use of relevant exposure assessment procedures referred to
in regulation 4. Where the exposure of workers to electromagnetic
fields exceeds the ELVs, the employer shall take immediate action
in accordance with regulation 5(8).
(3) For the purpose of these regulations, where it is
demonstrated that the relevant ALs set out in Schedules II and III
are not exceeded, the employer shall be deemed to be in
compliance with the health effects ELVs and sensory effects ELVs.
Where the exposure exceeds the ALs, the employer shall act in
accordance with regulation 5(2), unless the assessment carried out
in accordance with regulations 4(1), (2) and (3) demonstrates that
the relevant ELVs are not exceeded and that safety risks can be
excluded.
Notwithstanding the provisions of sub-regulation (1), exposure
may exceed
(a) low ALs for electric fields (Schedule II, Table B1),
where justified by the practice or process, provided
that either the sensory effects ELVs (Schedule II, Table
A3) are not exceeded; or
(i)
the health effects ELVs (Schedule II, Table A2)
are not exceeded;
(ii) the excessive spark discharges and contact
currents (Schedule II, Table B3) are prevented
by specific protection measures as set out in
regulation 5(6); and
(iii) information on the situations referred to in
regulation 6(f) has been given to workers;
(b) low ALs for magnetic fields (Schedule II, Table B2)
where justified by the practice or process, including in
the head and torso, during the shift, provided that
either the sensory effects ELVs (Schedule II, Table
A3) are not exceeded; or
(i) the sensory effects ELVs are exceeded only
temporarily;
(ii) the health effects ELVs (Schedule II, Table A2)
are not exceeded;
(iii) action is taken, in accordance with regulation
5(9), where there are transient symptoms under
paragraph (a) of that regulation; and
(iv) information on the situations referred to in
regulation 6(f) has been given to workers.
(4) Notwithstanding the provisions of sub-regulations (2) and
(3), exposure may exceed
(a) the sensory effects ELVs (Schedule II, Table A1)
during the shift, where justified by the practice or
process, provided that
(i) they are exceeded only temporarily;
(ii) the health effects ELVs (Schedule II, Table A1)
are not exceeded;
(iii) specific protection measures have been taken in
accordance with regulation 5(7);
(iv) action is taken in accordance with regulation
5(9), where there are transient symptoms under
paragraph (b) of that regulation; and
(v) information on the situations referred to in
regulation 6(f) has been given to workers;
(b) the sensory effects ELVs (Schedule II, Table A3 and
Schedule III, Table A2) during the shift, where
justified by the practice or process, provided that
(i) they are exceeded only temporarily;
(ii) the health effects ELVs (Schedule II, Table A2
and Schedule III, Table A1 and Table A3) are not
exceeded;
(iii) action is taken in accordance with regulation
5(9), where there are transient symptoms under
paragraph (a) of that regulation; and
(iv) information on the situations referred to in
regulation 6(f) has been given to workers.
THERMAL EFFECTS
EXPOSURE LIMIT VALUES AND ACTION LEVELS IN THE FREQUENCY
RANGE FROM 100 kHz TO 300 GHz
PART A.
EXPOSURE LIMIT VALUES (ELVs)
Health effects ELVs for frequencies from 100 kHz to 6 GHz (Table A1) are limits
for energy and power absorbed per unit mass of body tissue generated from exposure
to electric and magnetic fields.
Sensory effects ELVs for frequencies from 0.3 to 6 GHz (Table A2) are limits on
a b s o r b e d e n e rg y i n a s m a l l m a s s o f t i s s u e i n t h e h e a d f r o m e x p o s u r e t o
electromagnetic fields.
Health effects ELVs for frequencies above 6 GHz (Table A3) are limits for power
density of an electromagnetic wave incident on the body surface.
Table A1
Health effects ELVs for exposure to electromagnetic fields from 100 kHz to 6 GHz
Health effects ELVs
SAR values averaged over any
six-minute period
0.4 Wkg -1
E LV s r e l a t e d t o w h o l e b o d y h e a t s t r e s s
expressed as averaged SAR in the body
10 Wkg -1
ELVs related to localised heat stress in head
and trunk expressed as localised SAR in the
body
20 Wkg -1
ELVs related to localised heat stress in the
limbs expressed as localised SAR in the limbs
Note A1-1: Localised SAR averaging mass is any 10 g of contiguous tissue; the
maximum SAR so obtained should be the value used for estimating exposure. This 10
g of tissue is intended to be a mass of contiguous tissue with roughly homogeneous
electrical properties. In specifying a contiguous mass of tissue, it is recognised that
this concept may be used in computational dosimetry but may present difficulties for
direct physical measurements. A simple geometry, such as cubic or spheric tissue
mass, can be used.
Sensory effects ELVs from 0.3 GHz to 6 GHz
This sensory effects ELVs (Table A2) is related to avoiding auditory effects caused
by exposures of the head to pulsed microwave radiation.
Table A2
Sensory effects ELVs for exposure to electromagnetic fields from 0.3 to 6 GHz
Frequency range
Localised specific energy absorption
(SA)
10 mJkg -1
0.3 ≤ f ≤ 6 GHz
Note A2-1: Localised SA averaging mass is 10 g of tissue.
Table A3
Health effects ELVs for exposure to electromagnetic fields from 6 to 300 GHz
Frequency range
Health effects ELVs related to power
density
50 Wm -2
6 ≤ f ≤ 300 GHz
Note A3-1: The power density shall be averaged over any 20 cm 2 of exposed area.
Spatial maximum power densities averaged over 1 cm 2 should not exceed 20 times
the value of 50Wm -2 . Power densities from 6 to 10 GHz are to be averaged over
any six-minute period. Above 10 GHz, the power density shall be averaged over
any 68/f 1.05 -minute period (where f is the frequency in GHz) to compensate for
progressively shorter penetration depth, as the frequency increases.
PART B.
ACTION LEVELS (ALs)
The following physical quantities and values are used to specify the action levels
(ALs), the magnitude of which are established to ensure by simplified assessment the
compliance with the relevant ELVs or at which relevant protection or prevention
measures specified in regulation 5 must be taken
-
ALs(E) for electric field strength E of time varying electric field, as
specified in Table B1;
-
ALs(B) for magnetic flux density B of time varying magnetic field, as
specified in Table B1;
-
ALs(S) for power density of electromagnetic waves, as specified in
Table B1;
-
ALs(I C ) for contact current, as specified in Table B2;
-
ALs(I L ) for limb current, as specified in Table B2.
ALs correspond to calculated or measured field values at the workplace in the
absence of the worker, as maximum value at the position of the body or specified
part of the body.
Action levels (ALs) for exposure to electric and magnetic fields
ALs(E) and ALs(B) are derived from the SAR or power density ELVs (Tables A1
and A3) based on the thresholds related to internal thermal effects caused by
exposure to (external) electric and magnetic fields.
Table B1
ALs for exposure to electric and magnetic fields from 100 kHz to 300 GHz
Frequency range
Electric field
Magnetic flux
Power density
strength ALs(E)
density ALs(B)
ALs(S)
[Vm -1 ] (RMS)
[Wm -2 ]
[μT] (RMS)
6.1 × 10 2
2.0 × 10 6 /f
100 kHz ≤ f < 1 MHz
-
6.1 × 10 8 /f
2.0 × 10 6 /f
1≤ f < 10 MHz
-
10 ≤ f < 400 MHz
0.2
-
3 × 10 -3 f ½
1. 0 × 10 -5 f ½
400 MHz ≤ f < 2 GHz
-
1.4 × 10 2
4.5 × 10 -1
2 ≤ f < 6 GHz
-
1.4 × 10 2
4.5 × 10 -1
6 ≤ f ≤ 300 GHz
Note B1-1: f is the frequency expressed in hertz (Hz).
Note B1-2: [ALs(E)] 2 and [ALs(B)] 2 are to be averaged over a six-minute period.
For RF pulses, the peak power density averaged over the pulse width shall not
exceed 1000 times the respective ALs(S) value. For multi-frequency fields, the
analysis shall be based on summation, as explained in the practical guides made
available by the Commission.
Note B1-3: ALs(E) and ALs(B) represent maximum calculated or measured values
at the workers’ body position. This results in a conservative exposure assessment and
automatic compliance with ELVs in all non-uniform exposure conditions. In order
to simplify the assessment of compliance with ELVs, carried out in accordance
with regulation 4, in specific non-uniform conditions, criteria for the spatial
averaging of measured fields based on established dosimetry laid down in the
practical guides made available by the Commission. In the case of a very localised
source within a distance of a few centimetres from the body, compliance with ELVs
shall be determined dosimetrically, case by case.
Note B1-4: The power density shall be averaged over any 20 cm 2 of exposed area.
Spatial maximum power densities averaged over 1 cm 2 should not exceed 20 times
the value of 50Wm -2 . Power densities from 6 to 10 GHz are to be averaged over
any six-minute period. Above 10 GHz, the power density shall be averaged over
any 68/f 1.05 -minute period (where f is the frequency in GHz) to compensate for
progressively shorter penetration depth as the frequency increases.
Table B2
ALs for steady state contact currents and induced limb currents
Frequency range
Steady state contact
Induced limb current in
current, ALs(I C ) [mA]
any limb, ALs(I L ) [mA]
(RMS)
(RMS)
100 kHz ≤ f < 10 MHz
-
10 ≤ f ≤ 110 MHz
Note B2-1: [ALs(I L )] 2 is to be averaged over a six-minute period.
(1) The employer shall assess all risks for workers arising
from electromagnetic fields at the workplace and, if necessary,
measure or calculate the levels of electromagnetic fields to which
workers are exposed.
Without prejudice to regulation 12 of the General
Provisions for Health and Safety at Work Places Regulations and
regulation 6 of these regulations, that assessment can be made
public on request in accordance with relevant Union and national
laws and practice. In particular, in the case of processing the
personal data of employees in the course of such an assessment,
any publication shall comply with the Data Protection Act on the
protection of individuals with regard to the processing of personal
data and on the free movement of such data. Unless there is an
overriding public interest in disclosure, public authorities that are
in possession of a copy of the assessment may refuse a request for
access to it or a request to make it public, where disclosure would
undermine the protection of commercial interests of the employer,
including those relating to intellectual property. Employers may
refuse to disclose or make public the assessment under the same
conditions in accordance with the relevant Union and national laws
and practice.
(2) For the purpose of the assessment provided for in sub-
regulation (1) the employer shall identify and assess
electromagnetic fields at the workplace, taking into account the
relevant practical guides made available by the Commission and
ot h e r r e lev a n t s ta nd a r d s o r gu i de li ne s , in c l u di n g e x po s u r e
databases. Notwithstanding the employer’s obligations under this
regulation, the employer shall also be entitled, where relevant, to
take into account the emission levels and other appropriate safety-
related data provided, by the manufacturer or distributor, for the
equipment, in accordance with relevant Union law, including an
assessment of risks, if applicable to the exposure conditions at the
workplace or place of installation.
(3) If compliance with the ELVs cannot be reliably determined
on the basis of readily accessible information, the assessment of the
exposure shall be carried out on the basis of measurements or
calculations. In such a case, the assessment shall take into account
uncertainties concerning the measurements or calculations, such as
numerical errors, source modelling, phantom geometry and the
electrical properties of tissues and materials, determined in
accordance with relevant good practice.
(4) The assessment, measurement and calculations referred to
in sub-regulations ( 1), ( 2) and ( 3) shall be planned and carried
out by competent services or persons at suitable intervals, taking
into account the guidance given under these regulations and taking
particular account of regulations 9 and 13 of the General Provisions
for Health and Safety at Work Places Regulations. The data
obtained from the assessment, measurement or calculation of the
level of exposure shall be preserved in a suitable traceable form
so as to permit consultation at a later stage, in accordance with
national law and practice.
(5) When carrying out the risk assessment, the employer shall
give particular attention to the following
(a) the health effects ELVs, the sensory effects ELVs and
the ALs referred to in regulation 3 and Schedules II
and III;
(b) the frequency, the level, duration and type of exposure,
including the distribution over the worker’s body and
over the volume of the workplace;
(c) any direct biophysical effects;
(d) any effects on the health and safety of workers at
particular risk, in particular workers who wear active
or passive implanted medical devices, such as cardiac
pacemakers, workers with medical devices worn on the
body, such as insulin pumps, and pregnant workers;
(e) any indirect effects;
(f)
the existence of replacement equipment designed to
reduce the level of exposure to electromagnetic fields;
(g) appropriate information obtained from the health
surveillance referred to in regulation 8;
(h) information
provided
by
the
manufacturer
of
equipment;
(i)
other relevant health and safety related information;
(j)
multiple sources of exposure;
(k) simultaneous exposure to multiple frequency fields.
(6) In workplaces open to the public it is not necessary for the
exposure assessment to be carried out if an evaluation has already
been undertaken in accordance with the provisions on the limitation
of exposure of the general public to electromagnetic fields, if the
restrictions specified in those provisions are respected for workers
and if the health and safety risks are excluded. Where equipment
intended for the public use is used as intended and complies with
Union law on products that establish stricter safety levels than
those provided for by these regulations, and no other equipment is
used, these conditions are deemed to be met.
(7) The employer shall be in possession of an assessment of the
risks in accordance with regulation 10 of the General Provisions for
Health and Safety at Work Places Regulations, and shall identify
which measures must be taken in accordance with regulation 5 of
these regulations. The risk assessment may include the reasons why
the employer considers that the nature and the extent of the risks
related to electromagnetic fields make a further detailed risk
assessment unnecessary. The risk assessment shall be updated on a
regular basis, particularly if there have been significant changes
which could render it out of date, or if the results of the health
surveillance referred to in regulation 8 show this to be necessary.
(1) Taking account of technical progress and the
availability of measures to control the production of
electromagnetic fields at the source, the employer shall take the
necessary actions to ensure that risks arising from electromagnetic
fields at the workplace are eliminated or reduced to a minimum.
(2)
On the basis of the risk assessment referred to in regulation
4, once the relevant ALs, referred to in regulation 3 and in
Schedules II and III, are exceeded and unless the assessment
carried out in accordance with regulation 4(1), (2) and (3)
demonstrates that the relevant ELVs are not exceeded and that
safety risks can be excluded, the employer shall devise and
implement an action plan that shall include technical and, or
organisational measures to prevent exposure exceeding the health
effects ELVs and sensory effects ELVs, taking into account, in
particular
(a) other working methods that entail less exposure to
electromagnetic fields;
(b) the choice of equipment emitting less intense
electromagnetic fields, taking account of the work to
be done;
(c) technical measures to reduce the emission of
electromagnetic fields, including, where necessary, the
use of inter- locks, shielding or similar health
protection mechanisms;
(d) appropriate delimitation and access measures, such as
signals, labels, floor markings, barriers, in order to
limit or control access;
(e) in the case of exposure to electric fields, measures and
procedures to manage spark discharges and contact
currents through technical means and through the
training of workers;
(f)
appropriate maintenance programmes for work
equipment, workplaces and workstation systems;
(g) the design and layout of workplaces and workstations;
(h) limitations of the duration and intensity of the
exposure;
(i)
the availability of adequate personal protection
equipment.
(3) On the basis of the risk assessment referred to in regulation
4, the employer shall devise and implement an action plan that
shall include technical and, or organisational measures to prevent
any risks to workers at particular risk, and any risks due to
indirect effects, referred to in regulation 4.
(4) In addition to providing the information set out in
regulation 6, the employer shall adapt the measures referred to in
this regulation to the requirements of workers at particular risk and,
where applicable, to individual risks assessments, in particular in
respect of workers who have declared the use of active or passive
implanted medical devices, such as cardiac pacemakers, or the use
of medical devices worn on the body, such as insulin pumps, or in
respect of pregnant workers who have informed their employer of
their condition.
(5) On the basis of the risk assessment referred to in regulation
4, workplaces where workers are likely to be exposed to
electromagnetic fields that exceed the ALs shall be indicated by
appropriate signs in accordance with Schedules II and III and with
t h e Wor k P l a c e ( P r o v i s i o n of H e a l t h an d , or S a f e t y S i g ns )
Regulations. The areas in question shall be identified and access to
them limited, as appropriate. Where access to these areas is
suitably restricted for other reasons and workers are informed of
the risks arising from electromagnetic fields, signs and access
restrictions specific to electromagnetic fields shall not be required.
(6) Where regulation 3(3)(a) applies, specific protection
measures shall be taken, such as the training of workers in
accordance with regulation 6 and the use of technical means and
personal protection, for example the grounding of work objects, the
bonding of workers with work objects (equipotential bonding) and,
where appropriate and in accordance with Article 4(1)(a) of
Council Directive 89/656/EEC of 30 November 1989 on the
minimum health and safety requirements for the use by workers of
personal protective equipment at the workplace, the use of
insulating shoes, gloves and protective clothing.
(7) Where regulation 3(4)(a) applies, specific protection
measures, such as controlling movements, shall be taken.
(8) Workers shall not be exposed above the health effects ELVs
and sensory effects ELVs, unless the conditions under either
regulation 9(1)(a) or (c) or regulation 3(3) or (4) are fulfilled. If,
despite the measures taken by the employer, the health effects
ELVs and sensory effects ELVs are exceeded, the employer shall
take immediate action to reduce exposure below these ELVs. The
employer shall identify and record the reasons why the health
effects ELVs and sensory effects ELVs have been exceeded, and
shall amend the protection and prevention measures accordingly in
o rd e r t o pr e v e n t th e m b e i ng e xc e e ded a ga i n . Th e am e nd e d
protection and prevention measures shall be preserved in a suitable
traceable form so as to permit consultation at a later stage, in
accordance with national law and practice.
(9) Where the provisions of regulation 3(3) and (4) apply and
where the worker reports transient symptoms, the employer shall, if
necessary, update the risk assessment and the prevention measures.
Transient symptoms may include
(a) sensory perceptions and effects in the functioning of
the central nervous system in the head evoked by time
varying magnetic fields; and
(b) static magnetic field effects, such as vertigo and
nausea.
Without prejudice to the provisions of regulations 12 and
14 of the General Provisions for Health and Safety at Work Places
Regulations, the employer shall ensure that workers who are likely
to be exposed to risks from electromagnetic fields at work and, or
their representatives receive any necessary information and training
relating to the outcome of the risk assessment provided for in
regulation 4 of these regulations, concerning in particular
(a) measures taken in application of these regulations;
(b) the values and concepts of the ELVs and ALs, the
associated possible risks and the preventive measures
taken;
(c) the possible indirect effects of exposure;
(d) the results of the assessment, measurement or
calculations of the levels of exposure to
electromagnetic fields, carried out in accordance with
regulation 4;
(e) how to detect adverse health effects of exposure and
how to report them;
(f)
the possibility of transient symptoms and sensations
related to effects in the central or peripheral nervous
system;
(g) the circumstances in which workers are entitled to
health surveillance;
(h) safe working practices to minimise risks resulting
from exposure;
(i)
workers at particular risk, as referred to in regulation
4(5)(d) and regulation 5(3) and (4).
Consultation and participation of workers and, or their
representatives on the matters covered by these regulations and the
Schedules hereto, including the assessment, measurement and, or
calculations of the levels of exposure to electromagnetic fields
experienced at work, shall take place in accordance with the
G e n e r a l P r o v i s i o n s f o r H e a l t h a n d S a f e t y a t Wo r k p l a c e s
Regulations.
(1) With the objective of the prevention and the early
di a g no s i s of an y ad ve rs e h e a lt h e ff e c ts d ue t o ex p os u r e to
electromagnetic fields, an employer shall make arrangements for
carrying out appropriate health surveillance of workers exposed to
electromagnetic fields. Health records shall be made available to
the Authority.
(2) An employer shall ensure that the results of health
surveillance are preserved in a suitable form that allows them to be
consulted at a later date, subject to compliance with confidentiality
requirements. Individual workers shall, at their request, have access
to their own personal health records.
If any undesired or unexpected health effect is reported by a
worker, or in any event where exposure above the ELVs is detected,
the employer shall ensure that appropriate medical examinations or
individual health surveillance is provided to the worker(s).
Such examinations or surveillance shall be made available
during hours chosen by the worker, and any costs arising shall be
borne by the employer.
(1) By way of derogation from regulation 3 but without
prejudice to the provisions of regulation 5(1), the following shall
apply
(a) exposure may exceed the ELVs if the exposure is
related to the installation, testing, use, development,
maintenance of or research related to magnetic
resonance imaging (MRI) equipment for patients in the
health sector, provided that all the following
conditions are met
(i)
the risk assessment carried out in accordance
with regulation 4 has demonstrated that the
ELVs are exceeded;
(ii) given the state of the art, all technical and, or
organisational measures have been applied;
(iii) the circumstances duly justify exceeding the
ELVs;
(iv) the characteristics of the workplace, work
equipment, or work practices have been taken
into account; and
(v) the employer demonstrates that workers are still
protected against adverse health effects and
against safety risks, including by ensuring that
the instructions for safe use provided by the
manufacturer in accordance with Council
Directive 93/42/EEC of 14 June 1993
concerning medical devices are followed;
(b) the Minister responsible for defence may allow
equivalent or more specific protection systems to be
implemented for personnel working in operational
military installations or involved in military activities,
including in joint international military exercises,
provided that adverse health effects and safety risks
are prevented;
(c) the Authority may allow, in duly justified
circumstances and only for as long as they remain duly
justified, for the ELVs to be temporarily exceeded in
specific sectors or for specific activities outside the
scope of sub-regulation (1)(a) and (b). For the
purposes of this sub-regulation, "duly justified
circumstances" shall mean circumstances in which the
following conditions are met
(i) the risk assessment carried out in accordance
with regulation 4 has shown that the ELVs are
exceeded;
(ii) given the state of the art, all technical and, or
organisational measures have been applied;
(iii) the specific characteristics of the workplace,
work equipment, or work practices have been
taken into account; and
(iv)
the employer demonstrates that workers are still
protected against adverse health effects and
safety risks, including using comparable, more
specific and internationally recognised standards
and guidelines.
In such cases the employer shall inform the Authority in
writing before the start of these activities.
In any proceedings for an offence under these regulations
consisting of failure to comply with a duty or requirement to do
something, or to do something so far as is reasonably practicable, it
shall be for the accused to prove, as the case may be, that it was not
practicable or not reasonably practicable to do more than was in
fact done to satisfy the duty or requirement, or there was no better
practicable means than was in fact used to satisfy the duty or
requirement.
(1) Any breach by any person of any provision of these
regulations shall be deemed an offence.
(2) Any person who knowingly or recklessly interferes with the
performance of a duty or obligation by a person under these
regulations shall be guilty of an offence.