Electromagnetic Fields) Regulations, 2016
Table of Provisions (15)
Statutory Text (15 Articles)
L.N. 257 of 2016
OCCUPATIONAL HEALTH AND SAFETY AUTHORITY ACT
(CAP. 424)
Work Place (Minimum Health and Safety Requirements for the
Protection of Workers from Risks resulting from Exposure to
Electromagnetic Fields) Regulations, 2016
IN exercise of the powers conferred by article 12 of the
Occupational Health and Safety Authority Act, the Minister for
Social Dialogue, Consumer Affairs and Civil Liberties, after
consultation with the Occupational Health and Safety Authority, has
made the following regulations
(1)
The title of these regulations is the Work Place Citation, scope,
(Minimum Health and Safety Requirements for the Protection of applicability
commencement.
Workers from Risks resulting from Exposure to Electromagnetic
Fields) Regulations, 2016.
(2) The scope of these regulations is to lay down minimum
requirements for the protection of workers from risks to their health
and safety arising, or likely to arise, from exposure to electromagnetic
fields during their work. These regulations shall implement Directive
2013/35/EC of the European Parliament and of the Council. These
regulations cover all known direct biophysical effects and indirect
effects caused by electromagnetic fields.
(3) The exposure limit values (ELVs) laid down in these
regulations cover only scientifically well-established links between
short-term direct biophysical effects and exposure to electromagnetic
fields.
(4)
These regulations do not cover suggested long-term
effects.
(5) These regulations do not cover the risks resulting from
contact with live conductors.
(6) These regulations shall apply fully to all workers without
prejudice to more stringent and, or more specific provisions contained
in any other law or regulation on the protection of workers from the
risks related to exposure to electromagnetic fields.
(7) These regulations shall come into force on the 1st July
2016.
PHYSICAL QUANTITIES REGARDING THE EXPOSURE
TO ELECTROMAGNETIC FIELDS
The following physical quantities are used to describe the exposure to
electromagnetic fields
Electric field strength (E) is a vector quantity that corresponds to the force
exerted on a charged particle regardless of its motion in space. It is expressed in volt
per metre (Vm -1 ). A distinction has to be made between the environmental electric
field and the electric field present in the body (in situ) as a result of exposure
to the environmental electric field.
Limb current (I L ) is the current in the limbs of a person exposed to
electromagnetic fields in the frequency range from 10 MHz to 110 MHz as a result
of contact with an object in an electromagnetic field or the flow of capacitive
currents induced in the exposed body. It is expressed in ampere (A).
Contact current (I C ) is a current that appears when a person comes into
contact with an object in an electromagnetic field. It is expressed in ampere (A). A
steady state contact current occurs when a person is in continuous contact with an
object in an electromagnetic field. In the process of making such contact, a spark
discharge may occur with associated transient currents.
Electric charge (Q) is an appropriate quantity used for spark discharge and is
expressed in coulomb (C).
Magnetic field strength (H) is a vector quantity that, together with the
magnetic flux density, specifies a magnetic field at any point in space. It is
expressed in ampere per metre (Am -1 ).
Magnetic flux density (B) is a vector quantity resulting in a force that acts on
moving charges, expressed in tesla (T). In free space and in biological materials,
magnetic flux density and magnetic field strength can be interchanged using the
magnetic field strength of H = 1 Am -1 equivalence to magnetic flux density of B
= 4π 10 -7 T (approximately 1.25 microtesla).
Power density (S) is an appropriate quantity used for very high frequencies,
where the depth of penetration in the body is low. It is the radiant power incident
perpendicular to a surface, divided by the area of the surface. It is expressed in
watt per square metre (Wm -2 ).
Specific energy absorption (SA) is an energy absorbed per unit mass of
biological tissue, expressed in joule per kilogram (Jkg -1 ). In these regulations, it is
used for establishing limits for effects from pulsed microwave radiation.
Specific energy absorption rate (SAR), averaged over the whole body or over
parts of the body, is the rate at which energy is absorbed per unit mass of body
tissue and is expressed in watt per kilogram (Wkg -1 ). Whole-body SAR is a
widely accepted quantity for relating adverse thermal effects to radio frequency
(RF) exposure. Besides the whole-body average SAR, local SAR values are
necessary to evaluate and limit excessive energy deposition in small parts of the
body resulting from special exposure conditions. Examples of such conditions
include: an individual exposed to RF in the low MHz range (e.g. from dielectric
heaters) and individuals exposed in the near field of an antenna.
Of these quantities, magnetic flux density (B), contact current (I C ), limb
current (I L ), electric field strength (E), magnetic field strength (H), and power
density (S) can be measured directly.
In these regulations, unless the context otherwise requires -
"Act" means the Occupational Health and Safety Authority Act;
"action levels (ALs)" means operational levels established for
the purpose of simplifying the process of demonstrating the
compliance with relevant ELVs or, where appropriate, to take relevant
protection or prevention measures specified in these regulations.
The Action Level terminology used in Schedule II is as follows
(a)
for electric fields, "low ALs" and "high ALs"
means levels which relate to the specific protection or
prevention measures specified in these regulations; and
(b)
for magnetic fields, "low ALs" means levels which
relate to the sensory effects ELVs and "high ALs" to the health
effects ELVs;
"Authority" means the Occupational Health and Safety
Authority;
"Commission" means the Commission of the European Union;
"direct biophysical effects" means effects in the human body
directly caused by its presence in an electromagnetic field, including
(a)
thermal effects, such as tissue heating through
energy absorption from electromagnetic fields in the tissue;
(b)
non-thermal effects, such as the stimulation of
muscles, nerves or sensory organs. These effects might have a
detrimental effect on the mental and physical health of exposed
workers. Moreover, the stimulation of sensory organs may lead
to transient symptoms, such as vertigo or phosphenes. These
effects might create temporary annoyance or affect cognition or
other brain or muscle functions, and may thereby affect the
ability of a worker to work safely (i.e. safety risks); and
(c)
limb currents;
"electromagnetic fields" means static electric, static magnetic
and time-varying electric, magnetic and electromagnetic fields with
frequencies up to 300 GHz;
"exposure limit values (ELVs)" means values established on the
basis of biophysical and biological considerations, in particular on the
basis of scientifically well-established short-term and acute direct
effects, i.e. thermal effects and electrical stimulation of tissues;
"health effects ELVs" means those ELVs above which workers
might be subject to adverse health effects, such as thermal heating or
stimulation of nerve and muscle tissue;
"indirect effects" means effects, caused by the presence of an
object in an electromagnetic field, which may become the cause of a
safety or health hazard, such as
(a)
interference with medical electronic equipment and
devices, including cardiac pacemakers and other implants or
medical devices worn on the body;
(b)
the projectile risk from ferromagnetic objects in
static magnetic fields;
(c)
the
initiation
of
electro-explosive
devices
(detonators);
(d)
fires and explosions resulting from the ignition of
flammable materials by sparks caused by induced fields, contact
currents or spark discharges; and
(e)
contact currents;
"sensory effects ELVs" means those ELVs above which workers
might be subject to transient disturbed sensory perceptions and minor
changes in brain functions;
"Union" means the European Union.
NON-THERMAL EFFECTS
EXPOSURE LIMIT VALUES AND ACTION LEVELS IN THE FREQUENCY
RANGE FROM 0 Hz TO 10 MHz
PART A.
EXPOSURE LIMIT VALUES (ELVs)
ELVs below 1 Hz (Table A1) are limits for static magnetic field which is
not affected by the tissue of the body.
ELVs for frequencies from 1 Hz to 10 MHz (Table A2) are limits for electric
fields induced in the body from exposure to time-varying electric and magnetic
fields.
ELVs for external magnetic flux density from 0 to 1 Hz
The sensory effects ELV is the ELV for normal working conditions (Table
A1) and is related to vertigo and other physiological effects related to disturbance
of the human balance organ resulting mainly from moving in a static magnetic
field.
The health effects ELV for controlled working conditions (Table A1) is
applicable on a temporary basis during the shift when justified by the practice or
process, provided that preventive measures, such as controlling movements and
providing information to workers, have been adopted.
Table A1
ELVs for external magnetic flux density (B 0 ) from 0 to 1 Hz
Sensory effects ELVs
Normal working conditions
2 T
Localised limbs exposure
8 T
Health effects ELVs
Controlled working conditions
8 T
Health effects ELVs for internal electric field strength from 1 Hz to 10 MHz
Health effects ELVs (Table A2) are related to electric stimulation of all
peripheral and central nervous system tissues in the body, including the head.
Table A2
Health effects ELVs for internal electric field strength
from 1 Hz to 10 MHz
Frequency range
Health effects ELVs
1.1 Vm -1 (peak)
1 Hz ≤ f < 3 kHz
3.8 × 10 -4 f Vm -1 (peak)
3 kHz ≤ f ≤ 10 MHz
Note A2-1: f is the frequency expressed in hertz (Hz).
Note A2-2: The health effects ELVs for internal electric field are spatial peak
values in the entire body of the exposed subject.
Note A2-3: The ELVs are peak values in time which are equal to the Root-
Mean-Square (RMS) values multiplied by √2 for sinusoidal fields. In the case of
non-sinusoidal fields, exposure evaluation carried out in accordance with
regulation 4 shall be based on the weighted peak method (filtering in time
domain), explained in the practical guides made available by the Commission but
other scientifically proven and validated exposure evaluation procedures can be
applied, provided that they lead to approximately equivalent and comparable
results.
Sensory effects ELVs for internal electric field strength from 1 Hz to 400 Hz
The sensory effects ELVs (Table A3) are related to electric field effects on the
central nervous system in the head, i.e. retinal phosphenes and minor transient
changes in some brain functions.
Table A3
Sensory effects ELVs for internal electric field strength
from 1 to 400 Hz
Frequency range
Sensory effects ELVs
0.7/f Vm -1 (peak)
1 ≤ f < 10 Hz
0.07 Vm -1 (peak)
10 ≤ f < 25 Hz
0.0028 f Vm -1 (peak)
25 ≤ f ≤ 400 Hz
Note A3-1: f is the frequency expressed in hertz (Hz).
Note A3-2: The sensory effects ELVs for internal electric field are spatial
peak values in the head of the exposed subject.
Note A3-3: The ELVs are peak values in time which are equal to the Root-
Mean-Square (RMS) values multiplied by √2 for sinusoidal fields. In the case of
non-sinusoidal fields, the exposure evaluation carried out in accordance with
regulation 4 shall be based on the weighted peak method (filtering in time
domain), explained in the practical guides made available by the Commission, but
other scientifically proven and validated exposure evaluation procedures can be
applied, provided that they lead to approximately equivalent and comparable
results.
PART B. ACTION LEVELS (ALs)
The following physical quantities and values are used to specify the action
levels (ALs), the magnitude of which are established to ensure by simplified
assessment the compliance with relevant ELVs or at which relevant protection or
prevention measures specified in regulation 5 must be taken
-
Low ALs(E) and high ALs(E) for electric field strength E of
time varying electric fields as specified in Table B1;
-
Low ALs(B) and high ALs(B) for magnetic flux density B of
time varying magnetic fields as specified in Table B2;
-
ALs(I C ) for contact current as specified in Table B3;
-
ALs(B 0 ) for magnetic flux density of static magnetic fields as
specified in Table B4.
ALs correspond to calculated or measured electric and magnetic field values
at the workplace in the absence of the worker.
Action levels (ALs) for exposure to electric fields
Low ALs (Table B1) for external electric field are based on limiting the internal
electric field below the ELVs (Tables A2 and A3) and limiting spark discharges in
the working environment.
Below high ALs, the internal electric field does not exceed the ELVs (Tables
A2 and A3) and annoying spark discharges are prevented, provided that the
protection measures referred to in regulation 5(6) are taken.
Table B1
ALs for exposure to electric fields from 1 Hz to 10 MHz
Electric field strength
Electric field strength
Low ALs (E)[Vm -1 ]
High ALs (E) [Vm -1 ]
Frequency range
(RMS)
(RMS)
2.0 × 10 4
2.0 × 10 4
1 ≤ f < 25 Hz
5.0 × 10 5 /f
2.0 × 10 4
25 ≤ f < 50 Hz
5.0 × 10 5 /f
1.0 × 10 6 /f
50 Hz ≤ f < 1.64 kHz
5.0 × 10 5 /f
6.1 × 10 2
1.64 ≤ f < 3 kHz
1.7 × 10 2
6.1 × 10 2
3 kHz ≤ f ≤ 10 MHz
Note B1-1: f is the frequency expressed in hertz (Hz).
Note B1-2: The low ALs (E) and high ALs (E) are the Root-Mean-Square
(RMS) values of the electric field strength which are equal to the peak values
divided by √2 for sinusoidal fields. In the case of non-sinusoidal fields, the exposure
evaluation carried out in accordance with regulation 4 shall be based on the
weighted peak method (filtering in time domain), explained in the practical guides
made available by the Commission, but other scientifically proven and validated
exposure evaluation procedures can be applied, provided that they lead to
approximately equivalent and comparable results.
Note B1-3: ALs represent maximum calculated or measured values at the
workers’ body position. This results in a conservative exposure assessment and
automatic compliance with ELVs in all non-uniform exposure conditions. In
order to simplify the assessment of compliance with ELVs, carried out in
accordance with regulation 4, in specific non-uniform conditions, criteria for the
spatial averaging of measured fields based on established dosimetry laid down in
the practical guides made available by the Commission. In the case of a very
localised source within a distance of a few centimetres from the body, the induced
electric field shall be determined dosimetrically, case by case.
Action levels (ALs) for exposure to magnetic fields
Low ALs (Table B2) are, for frequencies below 400 Hz, derived from the
sensory effects ELVs (Table A3) and, for frequencies above 400 Hz, from the
health effects ELVs for internal electric field (Table A2).
High ALs (Table B2) are derived from the health effects ELVs for internal
electric field related to electric stimulation of peripheral and autonomous nerve
tissues in head and trunk (Table A2). Compliance with the high ALs ensures that
health effects ELVs are not exceeded, but the effects related to retinal phosphenes
and minor transient changes in brain activity are possible, if the exposure of the
head exceeds the low ALs for exposures up to 400 Hz. In such a case, regulation
5(6) applies.
ALs for exposure of limbs are derived from the health effects ELVs for
internal electric field related to electric stimulation of the tissues in limbs by
taking into account that the magnetic field is coupled more weakly to the limbs
than to the whole body.
Table B2
ALs for exposure to magnetic fields from 1 Hz to 10 MHz
Magnetic flux
density ALs for
Magnetic flux
Magnetic flux
exposure of
density Low
density High
Frequency range
limbs to a
ALs(B)[μT]
ALs(B) [μT]
localised
(RMS)
(RMS)
magnetic field
[μT] (RMS)
2.0 × 10 5 /f 2
3.0 × 10 5 /f
9.0 × 10 5 /f
1 ≤ f < 8 Hz
2.5 × 10 4 /f
3.0 × 10 5 /f
9.0 × 10 5 /f
8 ≤ f < 25 Hz
1.0 × 10 3
3.0 × 10 5 /f
9.0 × 10 5 /f
25 ≤ f < 300 Hz
3.0 × 10 5 /f
3.0 × 10 5 /f
9.0 × 10 5 /f
300 Hz ≤ f < 3 kHz
1.0 × 10 2
1.0 × 10 2
3.0 × 10 2
3 kHz ≤ f ≤ 10 MHz
Note B2-1: f is the frequency expressed in hertz (Hz).
Note B2-2: The low ALs and the high ALs are the Root-Mean-Square (RMS)
values which are equal to the peak values divided by √2 for sinusoidal fields. In the
case of non-sinusoidal fields the exposure evaluation carried out in accordance with
regulation 4 shall be based on the weighted peak method (filtering in time
domain), explained in the practical guides made available by the Commission, but
other scientifically proven and validated exposure evaluation procedures can be
applied, provided that they lead to approximately equivalent and comparable
results.
Note B2-3: ALs for exposure to magnetic fields represent maximum values at
the workers’ body position. This results in a conservative exposure assessment and
automatic compliance with ELVs in all non-uniform exposure conditions. In order
to simplify the assessment of compliance with ELVs, carried out in accordance
with regulation 4, in specific non-uniform conditions, criteria for the spatial
averaging of measured fields based on established dosimetry laid down in the
practical guides made available by the Commission. In the case of a very localised
source within a distance of a few centimetres from the body, the induced electric
field shall be determined dosimetrically, case by case.
Table B3
ALs for contact current I C
ALs (I C ) steady state contact current
Frequency
[mA] (RMS)
up to 2.5 kHz
1.0
2.5 ≤ f < 100 kHz
0.4 f
100 ≤ f ≤ 10 000 kHz
Note B3-1: f is the frequency expressed in kilohertz (kHz).
Action levels (ALs) for magnetic flux density of static magnetic fields
Table B4
ALs for magnetic flux density of static magnetic fields
Hazards
ALs(B 0 )
Interference with active implanted
devices, e.g. cardiac pacemakers
0.5 mT
Attraction and projectile risk in the
fringe field of high field strength
sources (> 100 mT)
3 mT
(1)
Physical quantities regarding exposure to Exposure limit
electromagnetic fields are indicated in Schedule I. Health effects values
action levels.
ELVs, sensory effects ELVs and ALs are set out in Schedules II and
III.
(2) Employers shall ensure that the exposure of workers to
electromagnetic fields is limited to the health effects ELVs and
sensory effects ELVs set out in Schedule II, for non-thermal effects,
and in Schedule III, for thermal effects. Compliance with health
effects ELVs and sensory effects ELVs must be established by the use
of relevant exposure assessment procedures referred to in regulation
THERMAL EFFECTS
EXPOSURE LIMIT VALUES AND ACTION LEVELS IN THE FREQUENCY
RANGE FROM 100 kHz TO 300 GHz
PART A.
EXPOSURE LIMIT VALUES (ELVs)
Health effects ELVs for frequencies from 100 kHz to 6 GHz (Table A1) are
limits for energy and power absorbed per unit mass of body tissue generated from
exposure to electric and magnetic fields.
Sensory effects ELVs for frequencies from 0.3 to 6 GHz (Table A2) are limits
on absorbed energy in a small mass of tissue in the head from exposure to
electromagnetic fields.
Health effects ELVs for frequencies above 6 GHz (Table A3) are limits for
power density of an electromagnetic wave incident on the body surface.
Table A1
Health effects ELVs for exposure to electromagnetic fields
from 100 kHz to 6 GHz
SAR values averaged over any six-
Health effects ELVs
minute period
ELVs related to whole body heat stress
0.4 Wkg -1
expressed as averaged SAR in the body
ELVs related to localised heat stress
in head and trunk expressed as
10 Wkg -1
localised SAR in the body
ELVs related to localised heat stress in
the limbs expressed as localised SAR in
20 Wkg -1
the limbs
Note A1-1: Localised SAR averaging mass is any 10 g of contiguous tissue;
the maximum SAR so obtained should be the value used for estimating exposure.
This 10 g of tissue is intended to be a mass of contiguous tissue with roughly
homogeneous electrical properties. In specifying a contiguous mass of tissue, it is
recognised that this concept may be used in computational dosimetry but may
present difficulties for direct physical measurements. A simple geometry, such as
cubic or spheric tissue mass, can be used.
Sensory effects ELVs from 0.3 GHz to 6 GHz
This sensory effects ELVs (Table A2) is related to avoiding auditory effects
caused by exposures of the head to pulsed microwave radiation.
Table A2
Sensory effects ELVs for exposure to electromagnetic fields
from 0.3 to 6 GHz
Localised specific energy absorption
Frequency range
(SA)
10 mJkg -1
0.3 ≤ f ≤ 6 GHz
Note A2-1: Localised SA averaging mass is 10 g of tissue.
Table A3
Health effects ELVs for exposure to electromagnetic fields
from 6 to 300 GHz
Health effects ELVs related to power
Frequency range
density
50 Wm -2
6 ≤ f ≤ 300 GHz
Note A3-1: The power density shall be averaged over any 20 cm 2 of exposed
area. Spatial maximum power densities averaged over 1 cm 2 should not exceed
20 times the value of 50Wm -2 . Power densities from 6 to 10 GHz are to be
averaged over any six-minute period. Above 10 GHz, the power density shall
be averaged over any 68/f 1.05 -minute period (where f is the frequency in GHz) to
compensate for progressively shorter penetration depth, as the frequency
increases.
PART B.
ACTION LEVELS (ALs)
The following physical quantities and values are used to specify the action
levels (ALs), the magnitude of which are established to ensure by simplified
assessment the compliance with the relevant ELVs or at which relevant protection
or prevention measures specified in regulation 5 must be taken
-
ALs(E) for electric field strength E of time varying electric
field, as specified in Table B1;
-
ALs(B) for magnetic flux density B of time varying magnetic
field, as specified in Table B1;
-
ALs(S) for power density of electromagnetic waves, as
specified in Table B1;
-
ALs(I C ) for contact current, as specified in Table B2;
-
ALs(I L ) for limb current, as specified in Table B2.
ALs correspond to calculated or measured field values at the workplace in
the absence of the worker, as maximum value at the position of the body or
specified part of the body.
Action levels (ALs) for exposure to electric and magnetic fields
ALs(E) and ALs(B) are derived from the SAR or power density ELVs
(Tables A1 and A3) based on the thresholds related to internal thermal effects
caused by exposure to (external) electric and magnetic fields.
Table B1
ALs for exposure to electric and magnetic fields
from 100 kHz to 300 GHz
Electric field
Magnetic flux
Power density
Frequency range
strength ALs(E)
density ALs(B)
ALs(S)
[Vm -1 ] (RMS)
[Wm -2 ]
[μT] (RMS)
6.1 × 10 2
2.0 × 10 6 /f
100 kHz ≤ f < 1 MHz
-
6.1 × 10 8 /f
2.0 × 10 6 /f
1≤ f < 10 MHz
-
10 ≤ f < 400 MHz
0.2
-
3 × 10 -3 f ½
1. 0 × 10 -5 f ½
400 MHz ≤ f < 2 GHz
-
1.4 × 10 2
4.5 × 10 -1
2 ≤ f < 6 GHz
-
1.4 × 10 2
4.5 × 10 -1
6 ≤ f ≤ 300 GHz
Note B1-1: f is the frequency expressed in hertz (Hz).
Note B1-2: [ALs(E)] 2 and [ALs(B)] 2 are to be averaged over a six-minute
period. For RF pulses, the peak power density averaged over the pulse width shall
not exceed 1000 times the respective ALs(S) value. For multi-frequency fields,
the analysis shall be based on summation, as explained in the practical guides
made available by the Commission.
Note B1-3: ALs(E) and ALs(B) represent maximum calculated or measured
values at the workers’ body position. This results in a conservative exposure
assessment and automatic compliance with ELVs in all non-uniform exposure
conditions. In order to simplify the assessment of compliance with ELVs,
carried out in accordance with regulation 4, in specific non-uniform conditions,
criteria for the spatial averaging of measured fields based on established
dosimetry laid down in the practical guides made available by the Commission. In
the case of a very localised source within a distance of a few centimetres from the
body, compliance with ELVs shall be determined dosimetrically, case by case.
Note B1-4: The power density shall be averaged over any 20 cm 2 of exposed
area. Spatial maximum power densities averaged over 1 cm 2 should not exceed
20 times the value of 50Wm -2 . Power densities from 6 to 10 GHz are to be
averaged over any six-minute period. Above 10 GHz, the power density shall
be averaged over any 68/f 1.05 -minute period (where f is the frequency in GHz) to
compensate for progressively shorter penetration depth as the frequency increases.
Table B2
ALs for steady state contact currents and induced limb currents
Steady state contact
Induced limb current in
Frequency range
current, ALs(I C ) [mA]
any limb, ALs(I L ) [mA]
(RMS)
(RMS)
100 kHz ≤ f < 10 MHz
-
10 ≤ f ≤ 110 MHz
Note B2-1: [ALs(I L )] 2 is to be averaged over a six-minute period.
€2.25
Where the exposure of workers to electromagnetic fields exceeds
the ELVs, the employer shall take immediate action in accordance
with regulation 5(8).
(3) For the purpose of these regulations, where it is
demonstrated that the relevant ALs set out in Schedules II and III are
not exceeded, the employer shall be deemed to be in compliance with
the health effects ELVs and sensory effects ELVs. Where the
exposure exceeds the ALs, the employer shall act in accordance with
regulation 5(2), unless the assessment carried out in accordance with
regulations 4(1), (2) and (3) demonstrates that the relevant ELVs are
not exceeded and that safety risks can be excluded.
Notwithstanding the provisions of sub-regulation (1), exposure
(a)
low ALs for electric fields (Schedule II, Table B1),
where justified by the practice or process, provided that either
the sensory effects ELVs (Schedule II, Table A3) are not
exceeded; or
(i) the health effects ELVs (Schedule II, Table
A2) are not exceeded;
(ii) the excessive spark discharges and contact
currents (Schedule II, Table B3) are prevented by specific
protection measures as set out in regulation 5(6); and
(iii) information on the situations referred to in
regulation 6(f) has been given to workers;
(b)
low ALs for magnetic fields (Schedule II, Table
B2) where justified by the practice or process, including in the
head and torso, during the shift, provided that either the sensory
effects ELVs (Schedule II, Table A3) are not exceeded; or
(i) the sensory effects ELVs are exceeded only
temporarily;
(ii) the health effects ELVs (Schedule II, Table
A2) are not exceeded;
(iii) action is taken, in accordance with regulation
5(9), where there are transient symptoms under paragraph
(a) of that regulation; and
(iv) information on the situations referred to in
regulation 6(f) has been given to workers.
(4) Notwithstanding the provisions of sub-regulations (2) and
(3), exposure may exceed
(a)
the sensory effects ELVs (Schedule II, Table A1)
during the shift, where justified by the practice or process,
provided that
(i)
they are exceeded only temporarily;
(ii) the health effects ELVs (Schedule II, Table
A1) are not exceeded;
(iii) specific protection measures have been taken
in accordance with regulation 5(7);
(iv) action is taken in accordance with regulation
5(9), where there are transient symptoms under paragraph
(b) of that regulation; and
(v) information on the situations referred to in
regulation 6(f) has been given to workers;
(b)
the sensory effects ELVs (Schedule II, Table A3
and Schedule III, Table A2) during the shift, where justified by
the practice or process, provided that
(i)
they are exceeded only temporarily;
(ii) the health effects ELVs (Schedule II, Table
A2 and Schedule III, Table A1 and Table A3) are not
exceeded;
(iii) action is taken in accordance with regulation
5(9), where there are transient symptoms under paragraph
(a) of that regulation; and
(iv) information on the situations referred to in
regulation 6(f) has been given to workers.
The employer shall assess all risks for workers Assessment of
arising from electromagnetic fields at the workplace and, if necessary, risks
determination of
measure or calculate the levels of electromagnetic fields to which exposure.
workers are exposed.
Without prejudice to regulation 12 of the General S.L. 424.18
Provisions for Health and Safety at Work Places Regulations and
regulation 6 of these regulations, that assessment can be made public
on request in accordance with relevant Union and national laws and
practice. In particular, in the case of processing the personal data of
employees in the course of such an assessment, any publication shall
comply with the Data Protection Act on the protection of individuals Cap. 440.
with regard to the processing of personal data and on the free
movement of such data. Unless there is an overriding public interest
in disclosure, public authorities that are in possession of a copy of the
assessment may refuse a request for access to it or a request to make it
public, where disclosure would undermine the protection of
commercial interests of the employer, including those relating to
intellectual property. Employers may refuse to disclose or make
public the assessment under the same conditions in accordance with
the relevant Union and national laws and practice.
(2) For the purpose of the assessment provided for in sub-
regulation (1) the employer shall identify and assess electromagnetic
fields at the workplace, taking into account the relevant practical
guides made available by the Commission and other relevant
standards
or
guidelines,
including
exposure
databases.
Notwithstanding the employer’s obligations under this regulation, the
employer shall also be entitled, where relevant, to take into account
the emission levels and other appropriate safety-related data
provided, by the manufacturer or distributor, for the equipment, in
accordance with relevant Union law, including an assessment of risks,
if applicable to the exposure conditions at the workplace or place of
installation.
(3) If compliance with the ELVs cannot be reliably determined
on the basis of readily accessible information, the assessment of the
exposure shall be carried out on the basis of measurements or
calculations. In such a case, the assessment shall take into account
uncertainties concerning the measurements or calculations, such as
numerical errors, source modelling, phantom geometry and the
electrical properties of tissues and materials, determined in
accordance with relevant good practice.
(4) The assessment, measurement and calculations referred to
in sub-regulations (1), ( 2) and ( 3) shall be planned and carried out
by competent services or persons at suitable intervals, taking into
account the guidance given under these regulations and taking
particular account of regulations 9 and 13 of the General Provisions
for Health and Safety at Work Places Regulations. The data obtained
from the assessment, measurement or calculation of the level of
exposure shall be preserved in a suitable traceable form so as to
permit consultation at a later stage, in accordance with national law
and practice.
(5) When carrying out the risk assessment, the employer shall
give particular attention to the following
(a)
the health effects ELVs, the sensory effects ELVs
and the ALs referred to in regulation 3 and Schedules II and
III;
(b)
the frequency, the level, duration and type of
exposure, including the distribution over the worker’s body and
over the volume of the workplace;
(c)
any direct biophysical effects;
(d)
any effects on the health and safety of workers at
particular risk, in particular workers who wear active or passive
implanted medical devices, such as cardiac pacemakers,
workers with medical devices worn on the body, such as insulin
pumps, and pregnant workers;
(e)
any indirect effects;
(f)
the existence of replacement equipment designed
to reduce the level of exposure to electromagnetic fields;
(g)
appropriate information obtained from the health
surveillance referred to in regulation 8;
(h)
information provided by the manufacturer of
equipment;
(i)
other
relevant
health
and
safety
related
information;
(j)
multiple sources of exposure;
(k)
simultaneous exposure to multiple frequency
fields.
(6) In workplaces open to the public it is not necessary for the
exposure assessment to be carried out if an evaluation has already
been undertaken in accordance with the provisions on the limitation
of exposure of the general public to electromagnetic fields, if the
restrictions specified in those provisions are respected for workers
and if the health and safety risks are excluded. Where equipment
intended for the public use is used as intended and complies with
Union law on products that establish stricter safety levels than those
provided for by these regulations, and no other equipment is used,
these conditions are deemed to be met.
(7) The employer shall be in possession of an assessment of
the risks in accordance with regulation 10 of the General Provisions S.L. 424.18
for Health and Safety at Work Places Regulations, and shall identify
which measures must be taken in accordance with regulation 5 of
these regulations. The risk assessment may include the reasons why
the employer considers that the nature and the extent of the risks
related to electromagnetic fields make a further detailed risk
assessment unnecessary. The risk assessment shall be updated on a
regular basis, particularly if there have been significant changes
which could render it out of date, or if the results of the health
surveillance referred to in regulation 8 show this to be necessary.
(1)
Taking account of technical progress and the
availability of measures to control the production of electromagnetic
fields at the source, the employer shall take the necessary actions to
ensure that risks arising from electromagnetic fields at the workplace
are eliminated or reduced to a minimum.
(2) On the basis of the risk assessment referred to in regulation
4, once the relevant ALs, referred to in regulation 3 and in Schedules
II and III, are exceeded and unless the assessment carried out in
accordance with regulation 4(1), (2) and (3) demonstrates that the
relevant ELVs are not exceeded and that safety risks can be excluded,
the employer shall devise and implement an action plan that shall
include technical and, or organisational measures to prevent exposure
exceeding the health effects ELVs and sensory effects ELVs, taking
into account, in particular
(a)
other working methods that entail less exposure to
electromagnetic fields;
(b)
the choice of equipment emitting less intense
electromagnetic fields, taking account of the work to be done;
(c)
technical measures to reduce the emission of
electromagnetic fields, including, where necessary, the use of
inter- locks, shielding or similar health protection mechanisms;
(d)
appropriate delimitation and access measures, such
as signals, labels, floor markings, barriers, in order to limit or
control access;
(e)
in the case of exposure to electric fields, measures
and procedures to manage spark discharges and contact currents
through technical means and through the training of workers;
(f)
appropriate maintenance programmes for work
equipment, workplaces and workstation systems;
(g)
the
design
and
layout
of
workplaces
and
workstations;
(h)
limitations of the duration and intensity of the
exposure;
(i)
the availability of adequate personal protection
equipment.
(3) On the basis of the risk assessment referred to in regulation
4, the employer shall devise and implement an action plan that
shall include technical and, or organisational measures to prevent any
risks to workers at particular risk, and any risks due to indirect
effects, referred to in regulation 4.
(4) In addition to providing the information set out in
regulation 6, the employer shall adapt the measures referred to in this
regulation to the requirements of workers at particular risk and, where
applicable, to individual risks assessments, in particular in respect of
workers who have declared the use of active or passive implanted
medical devices, such as cardiac pacemakers, or the use of medical
devices worn on the body, such as insulin pumps, or in respect of
pregnant workers who have informed their employer of their
condition.
(5) On the basis of the risk assessment referred to in regulation
4, workplaces where workers are likely to be exposed to
electromagnetic fields that exceed the ALs shall be indicated by
appropriate signs in accordance with Schedules II and III and with the
Work Place (Provision of Health and, or Safety Signs) Regulations. S.L. 424.16
The areas in question shall be identified and access to them limited,
as appropriate. Where access to these areas is suitably restricted for
other reasons and workers are informed of the risks arising from
electromagnetic fields, signs and access restrictions specific to
electromagnetic fields shall not be required.
(6) Where regulation 3(3)(a) applies, specific protection
measures shall be taken, such as the training of workers in accordance
with regulation 6 and the use of technical means and personal
protection, for example the grounding of work objects, the bonding of
workers with work objects (equipotential bonding) and, where
appropriate and in accordance with Article 4(1)(a) of Council
Directive 89/656/EEC of 30 November 1989 on the minimum health
and safety requirements for the use by workers of personal protective
equipment at the workplace, the use of insulating shoes, gloves and
protective clothing.
(7) Where regulation 3(4)(a) applies, specific protection
measures, such as controlling movements, shall be taken.
(8) Workers shall not be exposed above the health effects
ELVs and sensory effects ELVs, unless the conditions under either
regulation 9(1)(a) or (c) or regulation 3(3) or (4) are fulfilled. If,
despite the measures taken by the employer, the health effects ELVs
and sensory effects ELVs are exceeded, the employer shall take
immediate action to reduce exposure below these ELVs. The
employer shall identify and record the reasons why the health effects
ELVs and sensory effects ELVs have been exceeded, and shall amend
the protection and prevention measures accordingly in order to
prevent them being exceeded again. The amended protection and
prevention measures shall be preserved in a suitable traceable form so
as to permit consultation at a later stage, in accordance with national
law and practice.
(9) Where the provisions of regulation 3(3) and (4) apply and
where the worker reports transient symptoms, the employer shall, if
necessary, update the risk assessment and the prevention measures.
Transient symptoms may include
(a)
sensory perceptions and effects in the functioning
of the central nervous system in the head evoked by time
varying magnetic fields; and
(b)
static magnetic field effects, such as vertigo and
nausea.
Without prejudice to the provisions of regulations 12 and
14 of the General Provisions for Health and Safety at Work Places
Regulations, the employer shall ensure that workers who are likely to
be exposed to risks from electromagnetic fields at work and, or their
representatives receive any necessary information and training
relating to the outcome of the risk assessment provided for in
regulation 4 of these regulations, concerning in particular
(a)
measures taken in application of these regulations;
(b)
the values and concepts of the ELVs and ALs, the
associated possible risks and the preventive measures taken;
(c)
the possible indirect effects of exposure;
(d)
the results of the assessment, measurement or
calculations of the levels of exposure to electromagnetic fields,
carried out in accordance with regulation 4;
(e)
how to detect adverse health effects of exposure
and how to report them;
(f)
the possibility of transient symptoms and
sensations related to effects in the central or peripheral nervous
system;
(g)
the circumstances in which workers are entitled to
health surveillance;
(h)
safe working practices to minimise risks resulting
from exposure;
(i)
workers at particular risk, as referred to in
regulation 4(5)(d) and regulation 5(3) and (4).
Consultation and participation of workers and, or their Consultation
representatives on the matters covered by these regulations and the and
participation of
Schedules hereto, including the assessment, measurement and, or workers.
calculations of the levels of exposure to electromagnetic fields
experienced at work, shall take place in accordance with the General S.L. 424.18
Provisions for Health and Safety at Work places Regulations.
(1)
With the objective of the prevention and the early Health
diagnosis of any adverse health effects due to exposure to surveillance.
electromagnetic fields, an employer shall make arrangements for
carrying out appropriate health surveillance of workers exposed to
electromagnetic fields. Health records shall be made available to the
Authority.
(2) An employer shall ensure that the results of health
surveillance are preserved in a suitable form that allows them to be
consulted at a later date, subject to compliance with confidentiality
requirements. Individual workers shall, at their request, have access
to their own personal health records.
If any undesired or unexpected health effect is reported by
a worker, or in any event where exposure above the ELVs is detected,
the employer shall ensure that appropriate medical examinations or
individual health surveillance is provided to the worker(s).
Such examinations or surveillance shall be made available
during hours chosen by the worker, and any costs arising shall be
borne by the employer.
(1)
By way of derogation from regulation 3 but Derogations.
without prejudice to the provisions of regulation 5(1), the following
shall apply
(a)
exposure may exceed the ELVs if the exposure is
related to the installation, testing, use, development,
maintenance of or research related to magnetic resonance
imaging (MRI) equipment for patients in the health sector,
provided that all the following conditions are met
(i) the risk assessment carried out in accordance
with regulation 4 has demonstrated that the ELVs are
exceeded;
(ii) given the state of the art, all technical and, or
organisational measures have been applied;
(iii) the circumstances duly justify exceeding the
ELVs;
(iv) the characteristics of the workplace, work
equipment, or work practices have been taken into
account; and
(v) the employer demonstrates that workers are
still protected against adverse health effects and against
safety risks, including by ensuring that the instructions for
safe use provided by the manufacturer in accordance with
Council Directive 93/42/EEC of 14 June 1993 concerning
medical devices are followed;
(b)
the Minister responsible for defence may allow
equivalent or more specific protection systems to be
implemented for personnel working in operational military
installations or involved in military activities, including in joint
international military exercises, provided that adverse health
effects and safety risks are prevented;
(c)
the Authority may allow, in duly justified
circumstances and only for as long as they remain duly justified,
for the ELVs to be temporarily exceeded in specific sectors or
for specific activities outside the scope of sub-regulation (1)(a)
and (b). For the purposes of this sub-regulation, "duly justified
circumstances" shall mean circumstances in which the
following conditions are met
(i) the risk assessment carried out in accordance
with regulation 4 has shown that the ELVs are exceeded;
(ii) given the state of the art, all technical and, or
organisational measures have been applied;
(iii) the specific characteristics of the workplace,
work equipment, or work practices have been taken into
account; and
(iv) the employer demonstrates that workers are
still protected against adverse health effects and safety
risks, including using comparable, more specific and
internationally recognised standards and guidelines.
In such cases the employer shall inform the Authority in
writing before the start of these activities.
In any proceedings for an offence under these regulations Onus of proof.
consisting of failure to comply with a duty or requirement to do
something, or to do something so far as is reasonably practicable, it
shall be for the accused to prove, as the case may be, that it was not
practicable or not reasonably practicable to do more than was in fact
done to satisfy the duty or requirement, or there was no better
practicable means than was in fact used to satisfy the duty or
requirement.
(1)
Any breach by any person of any provision of these Offences.
regulations shall be deemed an offence.
(2) Any person who knowingly or recklessly interferes with
the performance of a duty or obligation by a person under these
regulations shall be guilty of an offence.