L.N. 227 of 2016
DEVELOPMENT PLANNING ACT
(CAP. 552)
Development Planning (Health and Sanitary) Regulations, 2016
BY VIRTUE of the powers conferred by articles 84 and 93 of
the Development Planning Act, the Parliamentary Secretary for
Planning and the Simplification of Administrative Processes, after
consultation with the Planning Authority, has made the following
regulations:-
(1)
The title of these regulations is the Development
Planning (Health and Sanitary) Regulations, 2016.
(2) These regulations shall come into force on the 10th June,
2016
Provided that
(a)
for development applications submitted in terms of
the Act, these regulations shall apply to development
applications validated after the 10th June 2016; and
(b)
for development applications submitted in terms of
the Act, and which were validated prior to the 10th June 2016,
the applicant may, within two months from the 10th June 2016,
request the Authority to determine his application under the
provisions of Code of Police or under the provisions of these
regulations. If no communication is forthcoming, the
application shall be determined under the provisions of these
regulations.
(3) In determining development applications submitted in
terms of the Act, the Authority shall apply the provisions of these
regulations without prejudice to the provisions of article 72 of the
Act.
(1)
In these regulations, unless the context otherwise
requires
"the Act" means the Development Planning Act;
"alterations" means structural changes to buildings;
"aperture" means an opening which allows natural light and
ventilation into a habitable space;
"Authority" has the same meaning as is assigned to it in article 2
of the Act;
"back yard" means an unroofed area at the rear of the structure
which shall be an integral part of the same site, to provide adequate
light and cross-ventilation to structures with over fifteen metres
depth;
"basement" has the same meaning assigned to it in the
Development Control Policy, Design Guidance and Standards of
2015, as may be subsequently amended;
"clear height" means the distance measured from the finished
floor level up to the underside of the ceiling level. This excludes any
beams, arches and, or drop ceilings, provided that these do not take up
more than 30% of the ceiling area of the room and the clear height of
this 30% area is not less than 2.0 metres;
"commercial development" is any development related to retail,
offices, food and drink, tourism, entertainment, industrial and
warehousing, or a mixture of these uses;
"corner site" means a site located at the intersection of two
streets;
"courtyard" means an unroofed area in existing buildings
constructed up to 1967 and shall be an integral part of the same site;
"dwelling" means a structure used as a residence and it must
consist, at least, of a kitchen, bedroom, and sanitary facilities;
"habitable space" means any space larger than six meters
squared, excluding bathrooms, circulation space, walk-in wardrobes,
domestic stores, engine rooms, lift shafts, garages, games rooms and
commercial developments;
"internal yard" means an unroofed area, not located at the rear
of the structure, intended to provide adequate light and cross-
ventilation to habitable space over 15 metres depth and shall be an
integral part of the same site. The minimum width of an internal yard
shall be one metre and fifty centimetres;
"non-habitable space" means any space which does not fall
within the definition "habitable space";
"residential structure" means a building used as a dwelling;
"restricted site" means a site or a structure with a depth of
fifteen metres or less;
"shaft" means an unroofed area with sufficient area to provide
cross-ventilation and, or space for the location of ducts and gulleys
for storm and foul water.
PART I
Preamble
(1)
These regulations are applicable to new structures
and to alterations to all existing structures.
(2) These regulations are not applicable to structures
constructed in, or prior to, 1967, save alterations to these structures
done thereafter.
(1)
In particular circumstances the Authority may
deviate from the exact definition of these regulations, if there are
justified planning and sanitary reasons for this departure. Such an
exemption may be granted without detriment to the structure in
question and the neighbouring properties, and shall not affect or
detract from the liability of the perit or of any other person in respect
of the stability or safety of the structure. Any deviations are to be
justified.
(2) Any departure from these regulations shall be decided by
the Authority and shall be subject to an appeal before the
Environment and Planning Review Tribunal.
All these regulations refer to both habitable and non-
habitable spaces, unless otherwise indicated.
These regulations may be subject to other specific
conditions contained in the relevant development permit.
It shall be lawful for any official duly authorised by the
Executive Council, in the course of or after the completion of the
work, to inspect the structure in order to ascertain whether the work,
both as regards the materials used and the mode of its execution,
conforms to the provisions of these regulations. The Executive
Council may, where necessary, request the assistance of the Police
and obtain a warrant authorizing the use of force, for access.
Any infringements of these regulations shall be subject to
enforcement action. All existing developments carried out post 1967
must conform to the conditions attached to the relative development
permit or to these regulations.
The Authority may request a warranted engineer’s report, New or updated
or an updated one, in relation to any approved development in warranted
engineer’s
relation to light and ventilation matters. Failure to submit such reports report.
within the requested time shall render the use of the building as
illegal, and enforcement action may be carried out accordingly.
PART II
Of Habitable and Non-Habitable Spaces
10.(1) (a) All new development should be provided with a Rules to be
water reservoir to store and re-use rainwater run-off from the built up observed
construction of
area and having a volume that is established in Technical Guidance reservoirs.
Document F - Conservation of Fuel, Energy and Natural Resources
(Minimum Requirements on the Energy Performance of Buildings
Regulations, 2006) and any subsequent revisions.
(b) Every water reservoir shall be connected to a pump
where the extraction of water so requires.
(1)
Each dwelling unit must have a frontage on a road, Dwellings to
have frontage on
valley or coast.
a street.
(2) Habitable and non-habitable spaces may be permitted at Spaces at
basement levels provided that they comply with these regulations. In basement level.
the case of both habitable spaces and non-habitable spaces, these are
to be adequately ventilated and illuminated and include either of the
following
(a)
an external aperture above pavement level; or
(b)
an external aperture overlooking
(i) a three metre front unroofed area even if
located below street level; or
(ii) at least a three metre deep unroofed area at
the back of the structure; or
(c)
for non-habitable spaces in basements only, a
warranted engineer certifies that they are adequately ventilated
and illuminated for their intended use. The Authority may
consider ventilation grids under pavements as a source of
adequate ventilation for such non-habitable spaces in
basements.
(3) Preference should always be given to natural light and Non-habitable
spaces above
ventilation for non-habitable spaces above ground level
ground level.
Provided that non-habitable spaces may be artificially
illuminated and ventilated, subject that certification by a warranted
engineer is submitted to the Authority stating that the design can
achieve acceptable levels of light and ventilation in accordance with
recognised building codes and standards.
(1)
Every habitable space shall be served with a
minimum cumulative external aperture area of at least one metre
squared.
(2) No overlying projections shall be allowed above apertures
with a cumulative area of less than one metre squared.
(1)
All habitable spaces are to be adequately ventilated
and illuminated in accordance with the provisions of this regulation to
ensure, in the opinion of the Authority, sufficient ingress of natural
light and free circulation of air.
(2) Every dwelling, except corner dwellings, with a depth of
more than fifteen metres, requires a back yard equivalent to at least
six metres width or to the entire plot width if such plot width is less
than six metres. The depth of the back yard shall be in accordance to
regulation 16.
(3) Toilets may be mechanically ventilated.
(4) (a)
Glazed automated retractable roofing over
courtyards providing ventilation to habitable spaces may be
considered provided that
(i) natural or mechanically automated ventilation
is provided;
(ii) the design shall be certified by a warranted
engineer that it can achieve acceptable levels of ventilation
in accordance with recognised building codes and
standards.
(b)
In the case of fixed glazed roofing, side ventilation
may be considered provided that the design is certified by a warranted
engineer that it can achieve acceptable levels of ventilation in
accordance with recognised building codes and standards.
(5) When a habitable space has an irregular shape and the
external apertures do not provide direct natural light and ventilation
to all the habitable space, a projection above any such aperture shall
not exceed one metre.
(1)
In streets or open spaces which are three metres Overall height
wide or less, the overall height of the façade should not exceed twice of the façade.
the width of the street or open space, which width shall be calculated
as the clear horizontal distance between the building frontage of the
façade and the building frontage of the nearest façade on the opposite
side of the street or open space. Height to width ratio does not apply
in the case of façades fronting the seafront or land outside the
development zone.
(2) In streets or open spaces which are wider than three meters
but less than or equal to fifteen metres, the overall height of the
façade should not exceed three times the width of the street or open
space which width shall be calculated as specified in sub-regulation
(1). Height to width ratio does not apply in the case of façades
fronting the seafront or land outside the development zone
Provided that additional floors above the overall height of
the façade stipulated under sub-regulations (1) and (2) may be
allowed provided adequate setbacks from the building alignment of
the façade are introduced. The setback for the additional floors shall
be of a dimension such that the ratio of the width of the street, as
specified in sub-regulation (1), and the setback, to the overall height
of the building, including the setback floors, shall never be less than
1:2 for street widths of three metres or less and never less than 1:3 for
street widths of more than three metres. Street widths shall be
measured as stipulated in sub-regulations (1) and (2)
Provide further that there may be exceptions depending on
the site context, in which case any façades which are higher than as
provided in this regulation are to respect the surrounding context.
(3) In streets or open spaces which are wider than fifteen
meters, the overall height of the façade can exceed three times the
width of the street, as specified in sub-regulation (1), without the need
for setbacks from the building alignment of the façade.
(1)
The clear height of
Height.
(a)
a habitable space shall not be less than two metres
and sixty centimetres;
(b)
a non-habitable space shall not be less than two
metres and forty centimetres, excluding engine rooms, lift
shafts, domestic stores, walk-in wardrobes and bathrooms,
which may have a clear height of less than two metres and forty
centimetres.
(2) Any intermediate floors within the height of any space can
be accommodated provided that the clear height of the intermediate
floor shall not be less than two metres and ten centimetres and
seventy percent of the space shall remain as double volume.
(1)
Every dwelling shall have a backyard with a depth
in proportion to the height of the building. The minimum depth of
these backyards, and internal yards and projections, where applicable,
shall be as specified hereunder
Height of façade
Depth of
overlooking the
Depth of
Depth of
projection
backyard and measured
Internal
Backyard
allowed in
from the internal floor
yard
backyard
level of the dwelling
Up to 10.1m
3.0m
3.0m
1.0m
> 10.1m to 14.1m
3.9m
3.5m
1.0m
> 14.1m to 18.6m
4.8m
4.0m
1.3m
> 18.6m to 21.6m
5.7m
4.5m
1.3m
> 21.6m to 25.6m
6.6m
5.0m
1.6m
> 25.6m to 28.6m
7.5m
5.5m
1.6m
> 28.6m to 32.1m
8.4m
6.0m
1.6m
> 32.1m
9.3m
6.5m
1.6m
(2) A minimum backyard and internal yard dimension of three
metres depth must be retained for a building height up to 10.1 metres
measured from the internal floor level of the dwelling. For each
overlying additional floor, a setback of one metre and fifty
centimetres for a backyard and of ninety centimetres for an internal
yard from the underlying floor, shall apply. In instances where there is
already an existing minimum back and, or an internal yard
(a)
for the backyard, a setback of two metres and thirty
centimetres may apply for every additional two floors instead of
having a one metre and fifty centimetre setback for each
additional floor;
(b)
for the internal yard, a setback of one metre and
forty centimetres for every additional two floors may be made
instead of ninety centimetres for every floor.
(3) For structures which are not used as dwellings with a
height of the façade overlooking the backyard and measured from the
internal floor level of up to six metres and forty centimetres, the
backyard shall have a minimum depth of one metre and fifty
centimetres. The provisions of sub-regulations (1) and (2) shall apply
for overlying floors.
In the case of structures having a frontage on two streets
Backyards in
relation to
structures
(a)
no backyard is required where each unit at the same
having a
frontage on two
level has a frontage on the two streets;
streets.
(b)
a backyard for every unit with a depth as set out in
regulation 16 is required if each unit at the same level does not
have a frontage on two streets provided that the depth of
backyard may be reduced by one third of the dimensions set out
in regulation 16 when each unit at the same level are permitted
through one development permission, and provided further that
when the reduced backyard is separated by a wall constructed in
a material used in the construction of buildings, the height of
this wall should not exceed 2.2m.
If, owing to the configuration of the site on which the Where back
structure is to be constructed, the back yard cannot be of the yard
of the prescribed
prescribed length or width, the Authority may permit a smaller length length or width.
or width, provided that, in the Authority’s opinion, such smaller
length or width, having regard to the particular circumstances of the
site, is sufficient to secure such natural light and ventilation as are
required for the wholesome condition of the structure.
No projections are permissible within internal yards or Projections on
shafts, unless the said internal yards or shafts are larger than the yards.
minimum required, and the maximum extent of the projection must
not exceed the surplus to the minimum required as set out in
regulation 16.
(1)
A structure in the backyard up to three metres Rooms within
external height may be permitted provided that the requirements backyards.
mentioned in regulations 13(2) and 16 are respected.
(2) In all cases, no access to the roof of the structure is
permitted.
Where a pre-1967 building includes a courtyard, which Courtyards in
courtyard does not serve as a backyard, any proposed additional pre-1967
buildings.
floors may be constructed without necessarily having the additional
floors recessed back from the courtyard alignment as required by
regulation 16(2), provided that a warranted engineer certifies that
they are adequately ventilated and illuminated.