Measures) Regulations, 2011
Table of Provisions (14)
Statutory Text (14 Articles)
Suppliment tal-Gazzetta tal-Gvern ta’ Malta Nru. 18,796, 26 ta’ Awwissu, 2011
L.N. 338 of 2011
PRODUCT SAFETY ACT
(CAP. 427)
Energy labelling of household air-conditioners (Implementing
Measures) Regulations, 2011
IN exercise of the powers conferred by articles 38 to 40 of
the Product Safety Act, the Prime Minister, on the advice of the
Malta Competition and Consumer Affairs Authority, has made the
following regulations:-
(1) The title of these regulations is the Energy Citation, scope and
labelling of household air-conditioners (Implementing Measures) commencement.
Regulations, 2011.
(2) These regulations shall be interpreted in terms of
the Indication by Labelling and Standard Product Information of
the Consumption of Energy and other Resources by Energy Related
Products Regulations, 2011, herein after referred to as “the Energy
Labelling Regulations”.
(3) These regulations implement the requirements
of Commission Directive 2002/31/EC of 22 March 2002
implementing Council Directive 92/75/EEC with regard to energy
labelling of household air-conditioners.
(4) These regulations constitute an implementing
measure within the meaning of the Energy Labelling Regulations
with regard to the energy labeling of household air-conditioners.
(5) These regulations shall come into force on the 20th
July, 2011.
(1) These regulations shall apply to electric mains
operated household air-conditioners as defined in the European
standards EN 255-1, EN 814-1 or the harmonised standards
referred to in sub-regulations 4(6) and 4(7) hereof.
(2)
These regulations shall not apply to the following
appliances
(a) appliances that can also use other energy sources;
(b) air-to-water and water-to-water appliances;
(c)
units with an output (cooling power) greater than
12 kW.
The definitions of the Energy Labelling Regulations shall
apply.
(1) The technical documentation referred to in
regulation 6(2)a of the Energy Labelling Regulations shall include
(a) the name and address of the supplier;
(b) a general description of the model, sufficient for it
to be uniquely and easily identified;
(c) information, including drawings as relevant, on
the main design features of the model and in particular items
which appreciably affect its energy consumption;
(d) reports of relevant measurement tests carried out
under the test procedures of the harmonised standards referred
to in regulation 4(6) and (7) hereof;
(e) operating instructions, if any.
Where the information relating to a particular model
combination has been obtained by calculation on the basis
of design, and/or extrapolation from other combinations, the
documentation should include details of such calculations and,or
extrapolations, and of tests undertaken to verify the accuracy of
the calculations undertaken (details of the mathematical model for
calculating performance of split systems, and of measurements
taken to verify this model).
(2) The label referred to in regulation 5(1) of the
Energy Labelling Regulations shall be as specified in Schedule I to
these regulations.
The label shall be placed on the outside of the front or
top of the appliance in such a way as to be clearly visible and not
obscured.
(3) The content and format of the fiche referred to in
regulation 5(2) of the Energy Labelling Regulations shall be as
specified in Schedule II to these regulations.
(4) Where the appliances are offered for sale, hire, or
hire purchase by means of a printed or written communication or
by other means which imply that the potential customer cannot
be expected to see the appliance displayed, such as a written
offer, a mail order catalogue, advertisements on the Internet or
other electronic media, that communication shall include all the
information specified in Schedule III to these regulations.
(5) The energy efficiency class of each air-conditioner
shall be determined in accordance with Schedule IV to these
regulations.
(6) The information required by these Regulations
shall be obtained by means of measurements made in accordance
with harmonised standards adopted by the European Committee
for Standardisation (CEN) under mandate from the Commission
in accordance with Directive 98/34/EC, the reference numbers of
which have been published in the Official Journal of the European
Communities and for which Member States have published the
reference numbers of the national standards transposing those
harmonised standards.
(7) The provisions of Schedules I, II and III to these
Regulations requiring the giving of information relating to noise
shall apply only where that information is required by Member
States under Article 3 of Directive 86/594/EEC. This information
shall be measured in accordance with that Directive.
Schedule I
Based on Annex I of Directive 2002/31/EC
LABEL
1. The label shall be the relevant language version chosen from the following
illustrations
B
!"#$%&'()&*((%+,-&(,%.&"//%+",*$0&1&!"#$%&2&
!
!
!
B
!"#$%&'()&*((%+,-34$"5+,-&"//%+",*$0&1&!"#$%&6!
!
!
B
2. The following notes define the information to be included
I. Supplier's name or trade mark.
II. Supplier's model identifier.
For ‘split and multi-split units’, the model identifier of the indoor and of the
outdoor elements of the combination to which the figures quoted below apply.
III. The energy efficiency class of the model or combination determined in
accordance with Schedule IV. The head of the arrow containing the indicator
letter shall be placed at the same level as the head of the relevant class arrow.
The height of the arrow containing the indicator letter shall not be less than —
and not more than twice — the height of the classes arrows.
IV. Without prejudice to any requirements under the Community eco-label
scheme, where a model has been granted a ‘European Union eco-label’ under
Regulation (EC) No 1980/2000 of the European Parliament and of the Council
of 17 July 2000 on a revised Community eco-label award scheme ( 1) , a copy of
the eco-label may be added here.
V. The indicative annual energy consumption calculated with the total input
power as defined in the harmonised standards referred to in regulations 4(6)
and 4(7) hereto multiplied by an average of 500 hours per year in cooling
mode at full load, determined in accordance with the test procedures of the
harmonised standards referred to in regulation 4(6) and 4(7) hereof
(conditions T1 ‘moderate’).
VI. The cooling output defined as the cooling capacity in kW of the appliance in
cooling mode at full load, determined in accordance with the test procedures of
the harmonised standards referred to in regulation 4(6) and (7) hereof
(conditions T1 ‘moderate’).
VII. The EER (energy efficiency ratio) of the appliance in cooling mode at full
load, determined in accordance with the test procedures of the harmonised
standards referred to in regulations 4(6) and (7) hereof (conditions T1
‘moderate’).
The type of appliance: cooling only, cooling/heating. This indicator arrow
shall be placed at the same level as the relevant type.
IX. The cooling mode: air cooled, water cooled. This indicator arrow shall be
placed at the same level as the relevant type.
1 OJ L 237, 21.9.2000, p. 1.
X. Only for appliances with heating capability (label 2) the heat output defined as
the heating capacity in kW of the appliance in heating mode at full load,
determined in accordance with the test procedures of the harmonised standards
referred to in regulations 4(6) and (7) hereof (conditions T1 + 7C).
XI. Only for appliances with heating capability (label 2) the heating mode energy
efficiency class in accordance with Schedule IV, expressed on a scale of A
(higher) to G (lower), determined in accordance with the test procedures of the
harmonised standards referred to in regulations 4(6) and (7) hereof (conditions
T1 + 7C). If the appliance heating capability is provided by a resistive element
then the COP (coefficient of performance) shall have the value of 1.
XII. Where applicable, noise measured during the function determining the energy
efficiency, determined in accordance with Directive 86/594/ EEC ( 2) .
The equivalent terms in other languages to those given above are set out in
Schedule V.
2 The relevant standards are EN 60704 -2-10 (noise measurement) and EN 60704-3 (verification).
B
Printing
3. The following defines certain aspects of the label
Colours used
CMYK — cyan, magenta, yellow, black.
Ex.07X0: 0 % cyan, 70 % magenta, 100 % yellow, 0 % black.
Arrows
A
X0X0
B
70X0
C
30X0
D
00X0
E
03X0
F
07X0
G
0XX0
Outline colour: X070
The background colour of the energy efficiency class indicator arrow is black.
All text is in black. The background is white.
!
B
Schedule II
Based on Annex II of Directive 2002/31/EC
FICHE
The fiche shall contain the following information. The information may be given in the
form of a table covering a number of models supplied by the same supplier, in which case
it shall be given in the order specified, or given close to the description of the appliance
1. Supplier's trade mark.
2. Supplier's model identifier.
For ‘split and multi-split units’, the model identifier of the indoor and of the
outdoor elements of the combination to which the figures quoted below apply.
3. The energy efficiency class of the model, determined in accordance with Schedule
IV. Expressed as ‘Energy efficiency class on a scale of A (more efficient) to G
(less efficient)’. Where this information is provided in a table this may be
expressed by other means provided it is clear that the scale is from A (more
efficient) to G (less efficient).
4. Where the information is provided in a table, and where some of the appliances
listed in the table have been granted a ‘European Union eco-label’ under
Regulation (EC) No 1980/2000, this information may be included here. In this
case the row heading shall state ‘European Union eco-label’, and the entry shall
consist of a copy of the eco-label mark. This provision is without prejudice to any
requirements under the Community eco-label scheme.
The indicative annual consumption of energy based on an average of 500 hours
per year, determined in accordance with the test procedures of the harmonised
standards referred to in regulation 4(6) and (7) hereof (conditions T1 ‘moderate’)
as defined in Schedule I, note VI.
The cooling output defined as the cooling capacity in kW of the appliance in
cooling mode at full load, determined in accordance with the test procedures of
the harmonised standards referred to in regulations 4(6) and (7) hereof (conditions
T1 ‘moderate’) as defined in Schedule I, note VI.
The EER (energy efficiency ratio) of the appliance in cooling mode at full load,
determined in accordance with the test procedures of the harmonised standards
referred to in regulation 4(6) and (7) hereof (conditions T1 ‘moderate’).
The type of appliance: cooling only, cooling/heating.
The cooling mode: air cooled, water cooled.
Only for appliances with heating capability the heat output defined as the heating
capacity in kW of the appliance in heating mode at full load, determined in
accordance with the test procedures of the harmonised standards referred to in
regulation 4(6) and (7) hereof (conditions T1 + 7C) as defined in Schedule I, note
VI.
Only for appliances with heating capability the heating mode energy efficiency
class in accordance with Schedule IV, expressed on a scale of A (higher) to G
(lower), determined in accordance with the test procedures of the harmonised
standards referred to in regulation 4(6) and (7) hereof (conditions T1 + 7C) as
defined in Schedule I, note VI. If the appliance heating capability is provided by
a resistive element then the COP (coefficient of performance) shall have the value
of 1.
Where applicable, noise measured during the function determining the energy
efficiency, determined in accordance with Directive 86/594/ EEC.
Suppliers may include in addition the information in points 5 to 8 in respect of
other test conditions determined in accordance with the test procedures of the
harmonised standards referred to in regulation 4(6) and (7) hereof.
If a copy of the label, either in colour or black and white is included in the fiche, then
only the further information needs to be added.
The equivalent terms in other languages to those given above are set out in Schedule V.
B
Schedule III
Based on Annex III of Directive 2002/31/EC
MAIL ORDER AND OTHER DISTANCE SELLING
Mail order catalogues, communications, written offers, advertisements on the Internet or
on other electronic media referred to in regulation 4(4) hereof shall contain the following
information, given in the order specified
1. Supplier's trade mark.
2. Supplier's model identifier.
For ‘split and multi-split units’, the model identifier of the indoor and of the
outdoor elements of the combination to which the figures quoted below apply.
3. The energy efficiency class of the model, determined in accordance with Schedule
IV. Expressed as ‘Energy efficiency class on a scale of A (more efficient) to G
(less efficient)’. Where this information is provided in a table this may be
expressed by other means provided it is clear that the scale is from A (more
efficient) to G (less efficient).
4. Where the information is provided in a table, and where some of the appliances
listed in the table have been granted a ‘European Union eco-label’ under
Regulation (EC) No 1980/2000, this information may be included here. In this
case the row heading shall state ‘European Union eco-label’, and the entry shall
consist of a copy of the eco-label mark. This provision is without prejudice to any
requirements under the Community eco-label scheme.
5. The indicative annual consumption of energy based on an average of 500 hours
per year, determined in accordance with the test procedures of the harmonised
standards referred to in regulation 4(6) and (7) hereof (conditions T1 ‘moderate’)
as defined in Schedule I, note VI.
6. The cooling output defined as the cooling capacity in kW of the appliance in
cooling mode at full load, determined in accordance with the test procedures of
the harmonised standards referred to in regulation 4(6) and (7) hereof (conditions
T1 ‘moderate’) as defined in Schedule I, note VI.
7. The EER (energy efficiency ratio) of the appliance in cooling mode at full load,
determined in accordance with the test procedures of the harmonised standards
referred to in regulation 4(6) and (7) hereof (conditions T1 ‘moderate’).
8. The type of appliance: cooling only, cooling/heating.
9. The cooling mode: air cooled, water cooled.
10. Only for appliances with heating capability the heat output defined as the heating
capacity in kW of the appliance in heating mode at full load, determined in
accordance with the test procedures of the harmonised standards referred to in
regulation 4(6) and (7) hereof (conditions T1 + 7C) as defined in Schedule I, note
VI.
11. Only for appliances with heating capability the heating mode energy efficiency
class in accordance with Schedule IV, expressed on a scale of A (higher) to G
(lower), determined in accordance with the test procedures of the harmonised
standards referred to in regulation 4(6) and (7) hereof (conditions T1 + 7C) as
defined in Schedule I, note VI. If the appliance heating capability is provided by
a resistive element then the COP (coefficient of performance) shall have the value
of 1.
12. Where applicable, noise measured during the function determining the energy
efficiency, determined in accordance with Directive 86/594/ EEC.
13. Suppliers may include in addition the information in points 5 to 8 in respect of
other test conditions determined in accordance with the test procedures of the
harmonised standards referred to in regulation 4(6) and (7) hereof.
If a copy of the label, either in colour or black and white is included in the fiche, then
only the further information needs to be added.
The equivalent terms in other languages to those given above are set out in Schedule V.
B
Schedule IV
Based on Annex IV of directive 2002/31/EC
CLASSIFICATION
1. The energy efficiency class is then determined in accordance with the following
tables
where the EER (energy efficiency ratio) is determined in accordance with the test
procedures of the harmonised standards referred to in regulation 4(6) and (7) hereof at
conditions T1 ‘moderate’.
Table 1 — Air-cooled air-conditioners
Table 1.1.
Energy efficiency class
Split and multi-split appliances
A
3.20 < EER
B
3.20 ! EER > 3.00
C
3.00 ! EER > 2.80
D
2.80 ! EER > 2.60
E
2.60 ! EER > 2.40
F
2.40 ! EER > 2.20
G
2.20 ! EER
B
Table 1.2
Packaged (1)
Energy efficiency class
A
3.00 < EER
B
3.00 ! EER > 2.80
C
2.80 ! EER > 2.60
D
2.60 ! EER > 2.40
E
2.40 ! EER > 2.20
F
2.20 ! EER > 2.20
G
2.00 ! EER
(1)
Packaged ‘double ducts’ units (known commercially as ‘double ducts’) defined as
‘Air-conditioner completely positioned inside the conditioned space, with the condenser
air intake and air discharge connected to the outside by means of two ducts’, will be
classified according to Table 1.2 with a correction factor of – 0.4.
Table 1.3
Energy efficiency class
Single-duct
A
2.60 < EER
B
2.60 ! EER > 2.40
C
2.40 ! EER > 2.20
D
2.20 ! EER > 2.00
E
2.00 ! EER > 1.80
F
1.80 ! EER > 1.60
G
1.60 ! EER
B
Table 2 — Water-cooled air-conditioners
Table 2.1.
Energy efficiency class
Split and multi-split appliances
A
3.60 < EER
B
3.60 ! EER > 3.30
C
3.30 ! EER > 3.10
D
3.10 ! EER > 2.80
E
2.80 ! EER > 2.50
F
2.50 ! EER > 2.20
G
2.20 ! EER
Table 2.2.
Energy efficiency class
Packaged
A
4.40 < EER
B
4.40 ! EER > 4.10
C
4.10 ! EER > 3.80
D
3.80 ! EER > 3.50
E
3.50 ! EER > 3.20
F
3.20 ! EER > 2.90
G
2.90 ! EER
B
2. The heating mode energy efficiency class is then determined in accordance with the
following tables
where COP (coefficient of performance) is determined in accordance with the test
procedures of the harmonised standards referred to in regulation 4(6) and (7) hereof at
conditions T1 ‘moderate’.
Table 3 — Air-cooled air-conditioners – heating mode
Table 3.1.
Energy efficiency class
Split and multi-split appliances
A
3.60 < COP
B
3.60 ! COP > 3.40
C
3.40 ! COP > 3.20
D
3.20 ! COP > 2.80
E
2.80 ! COP > 2.60
F
2.60 ! COP > 2.40
G
2.40 ! COP
Table 3.2.
Packaged (1)
Energy efficiency class
A
3.40 < COP
B
3.40 ! COP > 3.20
C
3.20 ! COP > 2.80
D
2.80 ! COP > 2.60
E
2.60 ! COP > 2.10
F
2.10 ! COP > 1.80
G
1.80 ! COP
B
(1) Packaged ‘double ducts’ units (known commercially as ‘double ducts’) defined as
‘Air-conditioner completely positioned inside the conditioned space, with the condenser
air intake and air discharge connected to the outside by means of two ducts’, will be
classified according to Table 3.2 with a correction factor of – 0.4.
Table 3.3
Energy efficiency class
Single Duct
A
3.00 < COP
B
3.00 ! COP > 2.80
C
2.80 ! COP > 2.60
D
2.60 ! COP > 2.40
E
2.40 ! COP > 2.10
F
2.10 ! COP > 1.80
G
1.80 ! COP
B
Table 4 — Water-coooled air-conditioners – heating mode
Table 4.1.
Energy efficiency class
Split and multi-split appliances
A
4.00 < COP
B
4.00 ! COP > 3.70
C
3.70 ! COP > 3.40
D
3.40 ! COP > 3.10
E
3.10 ! COP > 2.80
F
2.80 ! COP > 2.50
G
2.50 ! COP
Table 4.2.
Energy efficiency class
Packaged
A
4.70 < COP
B
4.740 ! COP > 4.40
C
4.40 ! COP > 4.10
D
4.10 ! COP > 3.80
E
3.80 ! COP > 3.50
F
3.50 ! COP > 3.20
G
3.20 ! COP
B
Schedule V
Based on Annex V of Directive 2002/40/EC
TRANSLATION OF TERMS TO BE USED IN LABEL AND FICHE
€1.44