Aerosol Dispensers (Amendment) Regulations, 2009
Statutory Text (5 Articles)
Suppliment tal-Gazzetta tal-Gvern ta’ Malta Nru. 18,368, 23 ta’ Jannar, 2009
Taqsima B
L.N. 26 of 2009
PRODUCT SAFETY ACT
(CAP. 427)
Aerosol Dispensers (Amendment) Regulations, 2009
IN exercise of the powers conferred by articles 38 to 40 of
the Product Safety Act, the Minister of Finance, the Economy and
Investment, has on the advice of the Malta Standards Authority,
made the following regulations:-
(1) The title of these regulations is the Aerosols
Dispensers (Amendment) Regulations, 2009 and they shall be read
and construed as one with the Aerosols Dispensers Regulations,
2002, hereinafter referred to as “the principal regulations”.
(2) These regulations shall come into force on 29th
December, 2010.
Regulation 5 of the principal requirements shall be
amended as follows
(a) immediately after point 5.2.5 thereof, there shall be
added the following
“5.2.6. Where an aerosol dispenser contains
flammable components as defined in point 1.8 of the
Schedule but the aerosol dispenser is not considered as
“flammable” or “extremely flammable” according to the
criteria set out in point 1.9 of the Schedule, the quantity
of flammable material contained in the aerosol dispenser
must be stated clearly on the label, in the form of the
following legible and indelible wording: “X % by mass
of the contents are flammable”; and
(b) sub-regulation 5.5 thereof shall be deleted.
The Schedule to the principal regulations, shall be amended
as follows
contain any component which is classified as flammable
1.8.1 flammable liquid means a liquid having a flashpoint of not
more than 93 °C;
1.8.2 flammable solid means a solid substance or mixture which
is readily combustible, or may cause or contribute to fire as
a result of friction. Readily combustible solids are
powdered, granular, or pasty substances or mixtures which
are dangerous if they can be easily ignited by brief contact
with an ignition source, such as a burning match, and if the
flame spreads rapidly; and
1.8.3 flammable gas means a gas or gas mixture having a
flammable range with air at 20 °C and a standard pressure
of 1,013 bar;
This definition does not cover pyrophoric, self-heating or water-
reactive substances and mixtures, which shall never be
components of aerosol contents.”;
(b)
immediately after point 1.8 thereof, there shall be added the following
new point
“1.9. Flammable aerosols
For the purpose of this Directive, an aerosol is considered as non-
flammable”, “flammable” or “extremely flammable” according
to its chemical heat of combustion and mass content of
flammable components, as follows
(a) the aerosol is classified as “extremely flammable” if it
contains 85 % or more flammable components and the
chemical heat of combustion exceeds or is equal to 30 kJ/g;
(b) the aerosol is classified as “non-flammable” if it contains 1%
or less flammable components and the chemical heat of
combustion is less than 20 kJ/g; and
(c) all other aerosols will be submitted to the following
flammability classification procedures or shall be classified
as “extremely flammable”. The ignition distance test, the
enclosed space test and the foam flammability test shall
comply with point 6.3.
1.9.1. Flammable spray aerosols
In the case of spray aerosols the classification shall be made
taking into account the chemical heat of combustion and on the
basis of the results of the ignition distance test, as follows
1.9.1.1 If the chemical heat of combustion is less than 20 kJ/g
1.9.1.1.1 the aerosol is classified as “flammable” if ignition
occurs at a distance equal or greater than 15 cm but
less than 75 cm;
1.9.1.1.2 the aerosol is classified as “extremely flammable” if
ignition occurs at a distance of 75 cm or more; and
1.9.1.1.3 if no ignition occurs in the ignition distance test, the
enclosed space test shall be performed and in this
case, the aerosol is classified as “flammable” if the
time equivalent is less than or equal to 300 s/m3 or
the deflagration density is less than or equal to 300
g/m3; otherwise the aerosol is classified as “non-
flammable”.
If the chemical heat of combustion is equal to or more
than 20 kJ/g, the aerosol is classified as “extremely
flammable” if ignition occurs at a distance of 75 cm or
more; otherwise the aerosol is classified as
“flammable”.
1.9.2. Flammable foam aerosols
In the case of foam aerosols, the classification shall be made on
the basis of the results of the foam flammability test.
1.9.2.1 The aerosol product shall be classified as “extremely
flammable” if
1.9.2.1.1 the flame height is 20 cm or more and the flame
duration is two seconds or more; or
1.9.2.1.2 the flame height is 4 cm or more and the flame
duration is seven seconds or more.
1.9.2.2 The aerosol product which does not meet the criteria in
(a) is classified as “flammable” if the flame height is 4
cm or more and the flame duration is two seconds or
more.”;
(c)
immediately after the new point 1.9 thereof, there shall added the
following new point
“1.10. Chemical Heat of Combustion
The chemical heat of combustion ΔH c shall be either determined
by
1.10.1 acknowledged rules of technology, described e.g. in
standards such as ASTM D 240, ISO 13943 86.1 to 86.3
and NFPA 30B, or found in the scientifically established
literature; or
1.10.2 applying the following calculation method
The chemical heat of combustion (ΔH c ), in kilojoules per gram
(kJ/g), can be calculated as the product of the theoretical heat of
combustion (ΔH comb ), and a combustion efficiency, usually less
than 1,0 (a typical combustion efficiency is 0,95 or 95 %).
For a composite aerosol formulation, the chemical heat of
combustion is the summation of the weighted heats of
combustion for the individual components, as follows
ΔH c =
[w i % x ΔH C(i) ]
where
ΔHc = chemical heat of combustion (kJ/g) of the product;
wi% = mass fraction of component i in the product;
ΔHc(i) = specific heat of combustion (kJ/g) of component i in the
product.
The person responsible for the marketing of the aerosol dispenser shall
describe the method used for determining the chemical heat of
combustion in a document to be made readily available in an official
Community language at the address specified on the label in
accordance with point 5.2.1 of Regulation 5.2, if the chemical heat of
combustion is used as a parameter for assessing the flammability of
aerosols according to the provisions of this Regulation”;
(d)
immediately after the heading to Section 2 General provisions, there
shall be added the following point
“2.0 Without prejudice to specific provisions of the Annex on
requirements related to the flammability and pressure hazard, the
person responsible for the marketing of aerosol dispensers is
under an obligation to analyse the hazards in order to identify
those which apply to his aerosol dispensers. Where appropriate,
this analysis shall include a consideration of the risks resulting
from the inhalation of the spray ejected by the aerosol dispenser
under normal and reasonably foreseeable conditions of use,
taking into account droplet size distribution in conjunction with
physical and chemical properties of the contents. He must then
design, construct and test it and, if applicable, draft special
statements concerning its use, taking account of his analysis.”;
(e)
point 2.2(b) thereof, shall be substituted by the following
“(b) Where the aerosol is classified as “flammable” or “extremely
flammable” according to the criteria of point 1.9
(i) the flame symbol, in accordance with the model in Annex II to
Directive 67/548/EEC;
(ii) the indication “flammable” or “extremely flammable.”;
(f)
in point 2.3 thereof, for paragraph (a) and (b) there shall be substituted
the following
“(a) Whatever its contents, any additional operating precautions which
alert consumers to the specific dangers of the product; if the
aerosol dispenser is accompanied by separate instructions for use,
the latter must also reflect such operating precautions;
(b) Where the aerosol is classified as “flammable” or “extremely
flammable” according to the criteria of point 1.9, the following
warnings
(i) the safety phrases S2 and S16 laid down in Annex IV to
Directive 67/548/EEC;
(ii) “Do not spray on a naked flame or any incandescent
material”.”;
(g)
immediately after point 2.3 thereof, there shall be added the following
“2.4. Volume of the liquid phase
The volume of the liquid phase at 50 °C shall not exceed 90 % of
the net capacity.”;
(h)
for point 3.1.2. thereof, there shall be substituted the following
“3.1.2. Filling
At 50 °C, the pressure in the aerosol dispenser must not exceed
12 bar.
However, if the aerosol does not contain a gas or mixture of
gases having a flammable range with air at 20°C and a standard
pressure of 1,013 bar, the maximum allowable pressure at 50
°C is 13,2 bar.”
(i)
points 3.1.3., 4.1.5. and 4.2.4. thereof shall be deleted.
(j)
for point 6.1.4 thereof, there shall be substituted the following
Final inspection of filled aerosol dispensers
1.4.1. Aerosol dispensers shall be subject to one of the following
final test methods.
6.1.4.1.1 Hot water bath test
Each filled aerosol dispenser shall be immersed in a
hot water bath.
6.1.4.1.1.1
The temperature of the water bath and the
duration of the test shall be such that the
internal pressure reaches that which would be
exerted by its contents at a uniform
temperature of 50 °C.
6.1.4.1.1.2
Any aerosol dispenser showing visible
permanent distortion or a leak must be
rejected.
6.1.4.1.2 Hot final test methods
Other methods for heating the contents of aerosol
dispensers may be used if they guarantee that the
pressure and temperature in each filled aerosol
dispenser reach the values required for the hot water
bath test and distortions and leaks are detected with
same precision as in the case of the hot water bath
test.
6.1.4.1.3 Cold final test methods
An alternative cold final test method may be used if it
is in accordance with the provisions of an alternative
method to the hot water bath test for aerosol
dispensers specified in point 6.2.4.3.2.2 of Annex A to
Directive 94/55/EC.
6.1.4.2. For aerosol dispensers the contents of which undergo a
physical or chemical transformation changing their pressure
characteristics after filling and before first use, cold final test
methods according to point 6.1.4.1.3 should be applied.
6.1.4.3. In case of test methods according to points 6.1.4.1.2 and
6.1.4.1.3
6.1.4.3.1 The test method must be approved by a competent
authority.
6.1.4.3.2 The person responsible for the marketing of aerosol
dispensers must submit an application for approval to
a competent authority. The application must be
accompanied by the technical file describing the
method.
6.1.4.3.3 The person responsible for the marketing of aerosol
dispensers must, for surveillance purposes, keep the
approval of the competent authority, the technical file
describing the method and, if applicable, control
reports readily available at the address specified on
the label in accordance with point 5.2.1 of Regulation
5.2.
6.1.4.3.4 The technical file must be established in an official
Community language or a certified copy thereof must
be available.
6.1.4.3.5 “competent authority” means the authority designated
in each Member State under Directive 94/55/EC.”;
and
(k)
immediately after point 6.2 thereof, there shall be added the following
Tests on the flammability of aerosols
Ignition distance test for spray aerosols
6.3.1.1. Introduction
6.3.1.1.1. This test standard describes the method to determine
the ignition distance of an aerosol spray in order to
assess the associated flame risk. The aerosol is
sprayed in the direction of an ignition source at
intervals of 15 cm to observe if ignition and sustained
combustion of the spray takes place. Ignition and
sustained combustion is defined as when a stable
flame is maintained for at least five seconds. The
ignition source is defined as a gas burner with a blue,
non-luminous flame 4-5 cm in height.
6.3.1.1.2. This test is applicable to aerosol products with a spray
distance of 15 cm or more. Aerosol products with a
spray distance of less than 15 cm such as dispensing
foams, mousses, gels and pastes or fitted with a
metering valve, are excluded from this test. Aerosol
products that dispense foams, mousses, gels or pastes
are subject to testing under the aerosol foam
flammability test.
Apparatus and material
6.3.1.2.1. The following apparatus is required
Water bath maintained at 20 °C
accurate to ± 1 °C
Calibrated laboratory scales (balance) accurate to ± 0,1 g
Chronometer (stopwatch)
accurate to ± 0,2 s
Graduated scale, support and clamp
graduations in cm
Gas burner with support and clamp
Thermometer
accurate to ± 1 °C
Hygrometer
accurate to ± 5 %
Pressure gauge
accurate to ± 0,1 bar
Procedure
6.3.1.3.1. General requirements
6.3.1.3.1.1. Before testing, each aerosol dispenser shall be
conditioned and then primed by discharging for
approximately one second. The purpose of this
action is to remove non-homogeneous material
from the diptube.
6.3.1.3.1.2.
The instructions of use shall be strictly
followed, including whether the dispenser is
intended to be used in the upright or inverted
position. When shaking is required, shake
immediately before testing.
6.3.1.3.1.3. The test shall be carried out in a draught-free
environment capable of ventilation, with the
temperature controlled at 20 °C ± 5 °C and
relative humidity in the range 30-80 %.
6.3.1.3.1.4. Each aerosol dispenser is to be tested
(a)
when full according to the complete
procedure, with the gas burner in the range
of 15-90 cm distance from the actuator of
the aerosol can;
(b)
when 10-12 % full nominal (% by mass)
only one test, either at 15 cm distance from
the actuator when the spray from a full can
did not ignite at all, or at the flame ignition
distance of the spray of a full can plus 15
cm.
6.3.1.3.1.5. During the test, the can shall be positioned as
indicated by label instructions. The ignition
source shall be positioned accordingly.
6.3.1.3.1.6. The following procedure requires testing the
spray at intervals of 15 cm between the burner
flame and the aerosol actuator, in the range of
15-90 cm. It is efficient to start at 60 cm
distance between burner flame and aerosol
actuator. The distance between burner flame
and aerosol actuator shall be increased by 15
cm in the case of an ignition of the spray at 60
cm distance. The distance shall be decreased by
15 cm in the case of no ignition at 60 cm
distance between burner flame and aerosol
actuator. The aim of the procedure is to
determine the maximum distance between
aerosol actuator and burner flame that leads to
sustained combustion of the spray or to
determine that ignition could not be obtained at
15 cm distance between the burner flame and
the aerosol's actuator.
6.3.1.3.2. Test procedure
(a)
a minimum of 3 full aerosol dispensers per
product shall be conditioned to 20 °C ± 1 °C
with at least 95 % of the dispenser immersed in
the water for at least 30 min before each test (if
the aerosol is fully immersed, 30 min
conditioning is sufficient);
(b)
comply with general requirements. Record the
temperature and relative humidity of the
environment;
(c)
weigh an aerosol dispenser and note its mass;
(d)
determine the internal pressure and initial
discharge rate at 20 °C ± 1 °C (to eliminate
faulty or partly filled aerosol dispensers);
(e)
support the gas burner on a flat horizontal
surface or fix the burner to a support by means
of a clamp;
(f)
ignite the gas burner; the flame shall be non-
luminous and approximately 4-5 cm high;
(g)
place the actuator's exit orifice at the required
distance from the flame. The aerosol shall be
tested in the position it is designed to be used,
e.g. upright or inverted;
(h)
level the actuator's orifice and burner flame,
ensuring that the orifice is properly directed
towards and aligned with the flame (see Figure
6.3.1.1). The spray shall be expelled through the
top half of the flame;
Figure 6.3.1.1
(i)
comply with the general requirements regarding
shaking of the dispenser;
(j)
actuate the valve of the aerosol dispenser, to
discharge its contents for five seconds, unless
ignition occurs. If ignition occurs, continue
discharging and time the duration of the flame
for five seconds, from the start of ignition;
(k)
note the ignition results for the distance between
the gas burner and the aerosol dispenser in the
table provided;
(l)
if no ignition occurs during step (j), the aerosol
shall be tested in alternative orientations, e.g.
inverted for upright use products, to check if
ignition is obtained;
(m) repeat steps (g) to (l) twice more (a total of 3)
for the same can at the same distance between
the gas burner and the aerosol actuator;
(n)
repeat the test procedure for another two aerosol
cans of the same product at the same distance
between gas burner and aerosol actuator;
(o)
repeat steps (g) to (n) of the test procedure at a
distance between 15 and 90 cm between the
actuator of the aerosol can and the burner flame
depending on the outcome of each test (see also
6.3.1.3.1.4 and 6.3.1.3.1.5);
(p)
if no ignition occurs at 15 cm, the procedure is
finished for initially full cans. The procedure is
also finished when ignition and sustained
combustion is obtained at a distance of 90 cm. If
ignition could not be obtained at 15 cm distance,
record that ignition did not occur. The maximum
distance between burner flame and the aerosol's
actuator for which an ignition and sustained
combustion was observed is noted as the
“ignition distance”, in all other circumstances;
(q)
one test shall also be conducted on three cans of
10-12 % nominal fill level. These cans shall be
tested at a distance between the aerosol's
actuator and the burner flame of the ‘flame
ignition distance of full cans + 15 cm’;
(r)
discharge an aerosol can to a 10-12 % nominal
fill level (by mass) in bursts of 30 seconds
maximum. Observe a 300 seconds minimum
time period between bursts. During this interim
period dispensers shall be placed in the water
bath for conditioning;
(s)
repeat steps (g) to (n) for 10-12 % nominal fill
aerosol cans, omitting steps (l) and (m). This test
shall only be performed with the aerosol in one
position, e.g. upright or inverted, corresponding
with that which produced the ignition (if any)
for filled cans; and
(t)
record all results in the Table 6.3.1.1 as shown
below.
6.3.1.3.2.1. All experiments shall be performed in a fume
hood in a room that may be well ventilated.
Ventilation of the fume hood and room can be
applied for at least three minutes after each test.
Take all necessary safety precautions to prevent
the inhalation of combustion products.
6.3.1.3.2.2. The cans with a 10-12 % nominal fill level shall
be tested only once. The result tables need only
one result per can indicated.
6.3.1.3.2.3. When the test in the position in which the
dispenser is designed to be used gives a
negative result, the test shall be repeated in the
position of the dispenser most likely to result in
a positive result.
6.3.1.4.
Method of assessing results
6.3.1.4.1 All the results shall be recorded. Table 6.3.1.1 below
shows the model of ‘result table’ to be used.
Table 6.3.1.1
Temperature … O C
Date
Relevant humidity … %
Name of product
Net volume
Can 1
Can 2
Can 3
Initial level of
filling
Dispenser
Test
distance
15 cm
Ignition?
Y or N
30 cm
Ignition?
Y or N
45 cm
Ignition?
Y or N
60 cm
Ignition?
Y or N
75 cm
Ignition?
Y or N
90 cm
Ignition?
Y or N
Observations
– including
can position
6.3.2.
Enclosed space ignition test
6.3.2.1.
Introduction
This test standard describes the method to assess the
flammability of products emerging from aerosol
dispensers due to their propensity to ignite in an enclosed
or confined space. The contents of an aerosol dispenser are
sprayed into a cylindrical test vessel containing a burning
candle. If an observable ignition occurs, the elapsed time
and amount discharged is noted.
Apparatus and material
6.3.2.2.1 The following apparatus is required
Chronometer (stopwatch)
accurate to ± 0,2 s
Water bath maintained at 20 °C
accurate to ± 1 °C
Calibrated laboratory scales (balance) accurate to ± 0,1 g
Thermometer
accurate to ± 1 °C
Hygrometer
accurate to ± 5 %
Pressure gauge
accurate to ± 0,1
bar
Cylindrical test vessel
as detailed below
6.3.2.2.2 Preparation of test apparatus
6.3.2.2.2.1.
A cylindrical vessel approximately 200 dm3
volume, approximately 600 mm in diameter
and approximately 720 mm long and open at
one end shall be modified as follows
6.3.2.2.2.1.1 a closure system consisting of a hinged
cover shall be matched to the open end
of the receptacle; or
6.3.2.2.2.1.2 a plastic film 0,01 to 0,02 mm thick
may be used as a closure system. If the
test is carried out with a plastic film
this must be used as described below
Stretch the film over the open end of
the drum and hold it in place with an
elastic band. The strength of the band
shall be such that when placed around
the drum resting on its side, it stretches
by only 25 mm when a mass of 0,45 kg
is attached to its lowest point. Cut a 25
mm slit in the film, starting 50 mm
from the edge of the drum. Ensure that
the film is taut; or
6.3.2.2.2.1.3 at the other end of the drum drill a 50
mm diameter hole 100 mm from the
edge in such a way that the orifice is
uppermost when the receptacle is laid
down and ready for the test (Figure
6.3.2.1.)
Figure 6.3.2.1
6.3.2.2.2.1.4 on a 200 × 200 mm metal support place
a paraffin wax candle 20 to 40 mm in
diameter and 100 mm high. The candle
shall be replaced when having a height
of less than 80 mm. The candle's flame
is protected from the action of the
spray by a 150 mm wide, 200 mm high
deflector. This includes the plane
inclined at 45° produced 150 mm from
the base of the deflector (Figure
6.3.2.2.);
Figure 6.3.2.2
6.3.2.2.2.1.5 the candle placed on the metal support
shall be positioned midway between
the two ends of the drum (Figure
6.3.2.3);
Figure 6.3.2.3
6.3.2.2.2.1.6 the drum is laid on the ground or on a
support at a spot where the temperature
is between 15 °C and 25 °C. The
product to be tested will be sprayed
within the drum of roughly 200 dm3 in
which there will be a source of
ignition.
6.3.2.2.2.2. Usually, the product leaves the aerosol can at an
angle of 90° relevant to the vertical axis of the
can. The layout and procedure described refers
to this kind of aerosol product. In the case of
unusually operating aerosols (e.g. vertical-spray
aerosol dispensers) it will be necessary to record
changes to equipment and procedures in
accordance with good laboratory practice, such
as ISO/IEC 17025:1999 General requirements
for the competence of testing and calibration
laboratories.
Procedure
6.3.2.3.1.
General requirements
6.3.2.3.1.1. Before testing, each aerosol dispenser shall be
conditioned and then primed by discharging for
approximately 1 second. The purpose of this
action is to remove non-homogeneous material
from the diptube.
6.3.2.3.1.2. The instructions of use shall be strictly followed,
including whether the dispenser is intended to be
used in the upright or inverted position. When
shaking is required, shake immediately before
testing.
6.3.2.3.1.3. The tests shall be carried out in a draught-free
environment capable of ventilation, with the
temperature controlled at 20 °C ± 5 °C and
relative humidity in the range 30-80 %.
6.3.2.3.2. Test procedure
6.3.2.3.2.1
a minimum of 3 full aerosol dispensers per
product shall be conditioned to 20 °C ± 1 °C in
a water bath with at least 95 % of the dispenser
immersed in the water for at least 30 min (if
the aerosol is fully immersed, 30 min
conditioning is sufficient);
6.3.2.3.2.2
measure or calculate the actual volume of the
drum in dm3;
6.3.2.3.2.3
comply with general requirements. Record the
temperature and relative humidity of the
environment;
6.3.2.3.2.4
determine the internal pressure and initial
discharge rate at 20°C ± 1°C (to eliminate
faulty or partly filled aerosol dispensers);
6.3.2.3.2.5
weigh one of the aerosol dispensers and note its
mass;
6.3.2.3.2.6
light the candle and apply the closure system
(cover or plastic film);
6.3.2.3.2.7
place the aerosol dispenser actuator orifice 35
mm or closer for a wide spray product, from
the centre of the entrance hole in the drum.
Start the chronometer (stopwatch) and
following the instructions for use of the
product; direct the spray towards the centre of
the opposite extremity (cover or plastic film).
The aerosol shall be tested in the position it is
designed to be used, e.g. upright or inverted;
6.3.2.3.2.8
spray until ignition occurs. Stop the
chronometer and note the time elapsed. Re-
weigh the aerosol dispenser and note its mass;
6.3.2.3.2.9
ventilate and clean the drum removing any
residue likely to affect subsequent tests. Allow
the drum to cool if necessary; and
6.3.2.3.2.10 repeat the test procedure steps 6.3.2.3.2.4 to
6.3.2.3.2.9 for another two aerosol dispensers
of the same product (three in total, note: each
dispenser is only tested once);
Method of assessing results
6.3.2.4.1. A test report containing the following information
shall be drawn up
6.3.2.4.1.1 the product tested and its references;
6.3.2.4.1.2 the internal pressure and discharge rate of the
aerosol dispenser;
6.3.2.4.1.3 the temperature and relative air humidity of the
room;
6.3.2.4.1.4 for each test, the discharge time (s) needed to
achieve ignition (if the product does not ignite,
state this);
6.3.2.4.1.5 the mass of the product sprayed during each test
(in g);
6.3.2.4.1.6 the actual volume of the drum (in dm3).
6.3.2.4.2. The time equivalent (teq) needed to achieve ignition
in one cubic metre can be calculated as follows
teq = 1 000 × discharge time (s)
Actual volume of drum (dm 3 )
6.3.2.4.3 The deflagration density (Ddef) needed to achieve
ignition during the test may also be calculated as
follows
Ddef =1 000 × Amount of product dispensed
Actual volume of drum (dm 3 )
Aerosol foam flammability test
Introduction
6.3.3.1.1. This test standard describes the method to determine
the flammability of an aerosol spray emitted in the
form of a foam, mousse, gel or paste. An aerosol,
which emits a foam, mousse, gel or paste is sprayed
(approximately 5 g) on a watchglass and an ignition
source (candle, wax taper, match or lighter) is placed
at the base of the watchglass to observe if ignition
and sustained combustion of the foam, mousse, gel or
paste occurs. Ignition is defined as a stable flame
maintained for at least two seconds and a minimum 4
cm in height.
Apparatus and material
6.3.3.2.1. The following apparatus is required
Graduated scale, support and clamp gradations in cm
Fire-resistant watchglass roughly 150 mm in diameter
Chronometer (stopwatch)
accurate to ± 0,2 s
Candle, wax taper, match or lighter
Calibrated laboratory scales (balance) accurate to ± 0,1 g
Water bath maintained at 20 °C
accurate to ± 1 °C
Thermometer
accurate to ± 1 °C
Hygrometer
accurate to ± 5 %
Pressure gauge
accurate to ± 0,1
6.3.3.2.2. The watchglass is placed on a fire-resistant surface
within a draught-free area that may be ventilated
after each test. The graduated scale is positioned
exactly behind the watchglass and held vertically by
means of a support and clamp.
6.3.3.2.3. The scale is positioned in such a way that its origin is
on a level with the watchglass base in a horizontal
plane.
Procedure
6.3.3.3.1. General requirements
6.3.3.3.1.1. Before testing, each aerosol dispenser shall be
conditioned and then primed by discharging for
approximately 1 second. The purpose of this
action is to remove non-homogeneous material
from the diptube.
6.3.3.3.1.2.
The instructions of use shall be strictly
followed, including whether the dispenser is
intended to be used in the upright or inverted
position. When shaking is required, shake
immediately before testing.
6.3.3.3.1.3. The tests shall be carried out in a draught-free
environment capable of ventilation, with the
temperature controlled at 20 °C ± 5 °C and
relative humidity in the range of 30-80 %.
6.3.3.3.2 Test procedure
6.3.3.3.2.1
a minimum of four full aerosol dispensers per
product shall be conditioned to 20 °C ± 1 °C
with at least 95 % of the dispenser immersed
in the water for at least 30 min before each
test (if the aerosol is fully immersed, 30 min
conditioning is sufficient);
6.3.3.3.2.2
comply with general requirements. Record the
temperature and relative humidity of the
environment;
6.3.3.3.2.3
determine the internal pressure at 20°C ± 1 °C
(to eliminate faulty or partly filled aerosol
dispensers);
6.3.3.3.2.4 measure the discharge or flow rate of the aerosol
product to be examined, so that the amount of
test product dispensed can be more accurately
gauged;
6.3.3.3.2.5
weigh one of the aerosol dispensers and note
its mass;
6.3.3.3.2.6
on the basis of the measured discharge or flow
rate and following the manufacturer's
instructions, release approximately 5 g of the
product onto the centre of the clean
watchglass with the aim of producing a
mound no higher than 25 mm;
6.3.3.3.2.7
within five seconds of completion of discharge,
apply the source of ignition to the edge of the
sample at its base and at the same time start
the chronometer (stopwatch). If necessary, the
ignition source shall be removed from the
edge of the sample after approximately two
seconds, in order to clearly observe if ignition
has occurred. If no ignition of the sample is
apparent, the ignition source shall be
reapplied to the edge of the sample;
6.3.3.3.2.8 if ignition occurs note the following points
6.3.3.3.2.8.1 the maximum height of the flame in cm
above the base of the watchglass;
6.3.3.3.2.8.2 the flame duration in s; and
6.3.3.3.2.8.3 dry and re-weigh the aerosol dispenser
and calculate the mass of the released
product;
6.3.3.3.2.9
ventilate the test area immediately after each
test;
6.3.3.3.2.10
if ignition is not obtained and the released
product remains in the form of a foam or
paste throughout its period of use, steps (e) to
(i) shall be repeated. Allow the product to
stand for 30 sec, 1 min, 2 min or 4 min before
applying the ignition source;
6.3.3.3.2.11
repeat the test procedure steps (e) to (j) twice
more (a total of 3) for the same can; and
6.3.3.3.2.12
repeat the test procedure steps (e) to (k) for
another two aerosol cans (3 cans in total) of
the same product.
6.3.3.4.
Method of assessing results
6.3.3.4.1. A test report containing the following information
shall be drawn up
6.3.3.4.1.1 whether the product ignites;
6.3.3.4.1.2 maximum flame height in cm;
6.3.3.4.1.3 duration of flame in s; and if
6.3.3.4.1.4 the mass of the product was tested.”.