Dioxin-like PCBs in Feedingstuffs Rules, 2005
Table of Provisions (11)
Statutory Text (11 Articles)
L.N. 71 of 2005
VETERINARY SERVICES ACT
(CAP. 437)
Requirements for the Determination of Levels of Dioxins and
Dioxin-like PCBs in Feedingstuffs Rules, 2005
IN exercise of the powers conferred by article 5(2) of the Veterinary
Services Act, 2001, the Minister for Rural Affairs and the Environment
has made the following rules>–
(1) The title to these rules is the Requirements for the Title and scope.
Determination of Levels of Dioxins and Dioxin-like PCBs in
Feedingstuffs Rules, 2005.
(2) The scope of these rules is to implement the rules found
under European Union Council Directive 2002#70#EC establishing
requirements for the determination of dioxins and dioxin-like PCBs in
feedingstuffs.
For the purpose of these regulations –
METHODS OF SAMPLING FOR OFFICIAL CONTROL OF THE LEVELS OF DIOXINS
(PCDD/PCDF) AND THE DETERMINATION OF DIOXIN-LIKE PCBs IN CERTAIN
FEEDINGSTUFFS
1. Purpose and scope
The samples intended for the official control of the levels of dioxins (PCDD/PCDF) content, as
well for the determination of the content of dioxin like PCBs ( 1 ) in feedingstuffs, shall be taken
according to the provisions of European Union Commission Directive 76/371/EEC of 1 March
1976 establishing Community methods of sampling for the official control of feedingstuffs.
Aggregate samples thus obtained shall be considered as representative for the lots or sublots from
which they are taken. Compliance with maximum levels laid down in European Union Council
Directive 1999/29/EC shall be established on the basis of the levels determined in the laboratory
samples.
2. Compliance of the lot or sublot with the specification
The control laboratory shall analyse the laboratory sample for enforcement in duplicate analysis in
case the obtained result of the first analysis is less than 20 % below or above the maximum level,
and calculate the mean of the results. The lot is accepted if the result of the first analysis is more
than 20 % below the maximum level or where duplicate analysis is necessary if the mean conforms
to the respective maximum level as laid down in European Union Council Directive 1999/29/EC.
Table WHO TEFs for human risk assessment based on the conclusions of the World Health Organisation
meeting in Stockholm, Sweden, 15 to 18 June 1997 (Van den Berg et al., (1998) Toxic Equivalency Factors
(TEFs) for PCBs, PCDDs, PCDFs for Humans and for Wildlife. Environmental Health Perspectives,
106(12), 775).
Congener
TEF value
Congener
TEF value
Dibenzo-p-dioxins (PCDDs)
‘Dioxin-like’ PCBs: Non-ortho PCBs + Mono-ortho
2,3,7,8-TCDD
PCBs
1,2,3,7,8-PeCDD
Non-ortho PCBs
1,2,3,4,7,8-HxCDD
0,1
PCB 77
0,0001
1,2,3,6,7,8-HxCDD
0,1
PCB 81
0,0001
1,2,3,7,8,9-HxCDD
0,1
PCB 126
0,1
1,2,3,4,6,7,8-HpCDD
0,01
PCB 169
0,01
OCDD
0,0001
Mono-ortho PCBs
Dibenzofurans (PCDFs)
PCB 105
0,0001
2,3,7,8-TCDF
0,1
PCB 114
0,0005
1,2,3,7,8-PeCDF
0,05
PCB 118
0,0001
2,3,4,7,8-PeCDF
0,5
PCB 123
0,0001
1,2,3,4,7,8-HxCDF
0,1
PCB 156
0,0005
1,2,3,6,7,8-HxCDF
0,1
PCB 157
0,0005
1,2,3,7,8,9-HxCDF
0,1
PCB 167
0,00001
2,3,4,6,7,8-HxCDF
0,1
PCB 189
0,0001
1,2,3,4,6,7,8-HpCDF
0,01
1,2,3,4,7,8,9-HpCDF
0,01
OCDF
0,0001
Abbreviations used: T = tetra; Pe = penta; Hx = hexa; Hp = hepta; O = octa; CDD = chlorodibenzo-p-dioxin; CDF =
chlorodibenzofuran; CB = chlorobiphenyl.
Definitions.
“the competent authority” means the Veterinary Services
within Malta as provided under article 2 of the Veterinary Services
Act, or any other authority to which such responsibility has been
delegated by the Veterinary Services.
SAMPLE PREPARATION AND REQUIREMENTS FOR METHODS OF ANALYSIS USED
IN OFFICIAL CONTROL OF THE LEVELS OF DIOXINS (PCDD/PCDF) AND THE
DETERMINATION OF DIOXIN-LIKE PCBs IN CERTAIN FEEDINGSTUFFS
1. Objective and field of application
These requirements should be applied where feed materials and feedingstuffs are analysed for the
determination of the dioxins (polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated
dibenzofurans (PCDF)) and dioxin-like polychlorinated biphenyls (PCBs).
Monitoring for the presence of dioxins in feedingstuffs can be performed by a strategy involving a
screening method in order to select those samples with levels of dioxins and dioxin-like PCBs that are
less than 30 % to 40 % below or exceed the level of interest. The concentration of dioxins in those
samples with significant levels needs to be determined/confirmed by a confirmatory method.
Screening methods are methods that are used to detect the presence of dioxins and dioxin-like PCBs at
the level of interest. These methods have a capacity for a high sample throughput and are used to sift
large numbers of samples for potential positives. They are specifically designed to avoid false
negatives.
Confirmatory methods are methods that provide full or complementary information enabling the
dioxins and dioxin-like PCBs to be identified and quantified unequivocally at the level of interest.
2. Background
Because environmental and biological samples (including samples of feed materials/feedingstuffs) in
general contain complex mixtures of different dioxin congeners, the concept of toxic equivalency
factors (TEFs) has been developed to facilitate risk assessment. These TEFs have been established to
express concentrations of mixtures of 2,3,7,8-substituted PCDDs and PCDFs, and more recently, some
non-ortho and mono-ortho chlorine substituted PCBs which possess dioxin -like activity in toxic
equivalents (TEQs) of 2,3,7,8-TCDD (see Schedule I, footnote 1).
The concentrations of the individual substances in a given sample are multiplied by their respective
TEF and subsequently summed to give the total concentration of dioxin-like compounds expressed in
TEQs.
The concept of ‘upperbound’ requires using the limit of quantification for the contribution of each non-
quantified congener to the TEQ.
The concept of ‘lowerbound’ requires using zero for the contribution of each non-quantified congener
to the TEQ.
The concept of ‘mediumbound’ requires using half of the limit of quantification calculating the
contribution of each non-quantified congener to the TEQ.
3. Quality assurance requirements to be complied with for sample preparation
The general provisions on the preparation of samples for analysis as laid down in the Annex to
European Union Commission Directive 81/680/EEC of 30 July 1981 amending European Union
Directives 71/250/EEC, 71/393/EEC, 72/199/EEC, 73/46/EEC, 74/203/EEC, 75/84/EEC, 76/372/EEC
and 78/633/EEC establishing Community methods of analysis for the official control of feedingstuffs
are applicable.
In addition the following requirements have to be complied with
— the samples must be stored and transported in glass, aluminium, polypropylene or polyethylene
containers. Traces of paper dust must be removed from the sample container. Glassware should be
rinsed with solvents previously controlled for the presence of dioxins,
— perform a blank analysis by carrying out the entire analytical procedure omitting only the sample,
— sample weight used for the extraction must be sufficient to fulfil the requirements with respect to
sensitivity.
4. Requirements for laboratories
— Laboratories shall demonstrate the performance of a method in the range of the level of interest,
for example, 0,5 ×, 1 × and 2 × the level of interest with an acceptable coefficient of variation for
repeated analysis. For details of acceptance criteria, see point 5.
— Limit of quantification for a confirmatory method shall be in the range of about one-fifth of the
level of interest, to make sure that acceptable coefficients of variations are met in the range of the
level of interest.
— Regular blank controls and spiking experiments or analysis of control samples (preferably, if
available, certified reference material) shall be performed as internal quality control measures.
— Successful participation in interlaboratory studies that assess laboratory proficiency is the best way
to prove the competence in specific analyses. However successful participation in interlaboratory
studies for, for example, soil or sewage samples does not necessarily prove the competence also in
the field of food or feedingstuff samples, which present lower contamination levels. Therefore, the
continuous participation in interlaboratory studies for the determination of dioxins and dioxin-like
PCBs in the relevant feed/food matrices is mandatory.
— Laboratories shall be accredited by a recognised body operating in accordance with ISO Guide 58
to ensure that they are applying analytical quality assurance. Laboratories should be accredited
following the ISO/IEC/17025:1999 standard.
The competent authority shall ensure that the sampling for Sampling for the
the official control of the levels of dioxins and furans and the official
the levels of dioxins
determination of the levels of dioxin-like PCBs in feedingstuffs is carried and furans.
out in accordance with the methods described in Schedule I.
The competent authority shall ensure that sample preparation Sample preparation
and methods of analyses used for the official control of the levels of and
analyses.
dioxins and furans and the determination of the levels of dioxin-like
PCBs in feedingstuffs comply with the criteria described in Schedule
II.
Requirements for the analytical procedures for dioxins and dioxin-like PCBs
Basic requirements for acceptance of analytical procedures
— High sensitivity and low limits of detection. For PCDDs and PCDFs, detectable quantities have to
be in the picogram TEQ (10- 12 g) range because of extreme toxicity of some of these compounds.
PCBs are known to occur at higher levels than the PCDDs and PCDFs. For most PCB congeners
sensitivity in nanogram (10- 9 g) range is already sufficient. However, for the measurement of the
more toxic dioxin-like PCB congeners (in particular non-ortho substituted congeners), the same
sensitivity must be reached as for the PCDDs and PCDFs.
— High selectivity (specificity). A distinction is required for PCDDs, PCDFs and dioxin-like PCBs
from a multitude of other, coextracted and possibly interfering compounds present at
concentrations up to several orders of magnitude higher than those of the analytes of interest. For
gas chromatography/mass spectrometry (GC/MS) methods, a differentiation among various
congeners is necessary, such as between toxic (e.g. the seventeen 2,3,7,8-substituted PCDDs and
PCDFs and dioxin-like PCBs) and other congeners. Bioassays should be able to determine TEQ
values selectively as the sum of PCDDs, PCDFs and dioxin-like PCBs.
— High accuracy (trueness and precision). The determination should provide a valid and reliable
estimate of the true concentration in a sample. High accuracy (accuracy of the measurement: the
closeness of agreement between the result of a measurement with the true or assigned value of the
measurement) is necessary to avoid the rejection of a sample analysis result on the basis of poor
reliability of the estimate of TEQ. Accuracy is expressed as trueness (difference between the mean
value measured for an analyte in a certified material and its certified value, expressed as
percentage of this value) and precision (precision is usually calculated as a standard deviation
including repeatability and reproducibility, and indicates the closeness of agreement between the
results obtained by applying the experimental procedure several times under prescribed
conditions).
Screening methods can comprise bioassays and GC/MS methods; confirmatory methods are high-
resolution gas -chromatography/high-resolution mass-spectrometry (HRGC/HRMS) methods. The
following criteria have to be complied with on total TEQ value
Screening methods
Confirmatory Levels
False negative rate
< 1 %
Trueness
- 20 % to + 20 %
CV
< 30 %
Specific requirements for GC/MS methods to be complied with for screening or
confirmatory purposes
— Addition of 13C-labelled 2,3,7,8-chlorine substituted internal PCDD/F standards (and of 13C-
labelled internal dioxin-like PCB standards, if dioxin -like PCBs have to be determined) must be
carried out at the very beginning or start of the analytical method, for example, prior to extraction
in order to validate the analytical procedure. At least one congener for each of the tetra to octa-
chlorinated homologous groups for PCDD/F (and at least one congener for each of the
homologous groups for dioxin-like PCBs, if dioxin-like PCBs have to be determined) must be
added (alternatively, at least one congener for each mass spectrometric selected ion recording
function used for monitoring PCDD/F and dioxin-like PCBs). There is a clear preference, certainly
in case of confirmatory methods, of using all 17 13C-labelled 2,3,7,8-substituted internal PCDD/F
standards and all 12 13C-labelled internal dioxin-like PCB standard (if dioxin-like PCBs have to
be determined).
Relative response factors should also be determined for those congeners for which no 13C-labelled
analogue is added by using appropriate calibration solutions.
— For feedingstuffs of plant origin and feedingstuffs of animal origin containing less than 10 % fat,
the addition of the internal standards is mandatory prior to extraction. For feedingstuffs of animal
origin containing more than 10 % fat, the internal standards can be added either before extraction
or after fat extraction. An appropriate validation of the extraction efficiency should be carried out,
depending on the stage at which internal standards are introduced and on whether results are
reported on a product or fat basis.
— Prior to GC/MS analysis, one or two recovery (surrogate) standard(s) must be added.
— Control of recovery is necessary. For confirmatory methods, the recoveries of the individual
internal standards should be in the range of 60 % to 120 %. Lower or higher recoveries for
individual congeners, in particular for some hepta- and octa- chlorinated dibenzodioxins and
dibenzofurans, are acceptable on the condition that their contribution to the TEQ value does not
exceed 10 % of the total TEQ value (based on PCDD/F only). For screening methods, the
recoveries should be in the range of 30 % to 140 %.
— Separation of dioxins from interfering chlorinated compounds such as PCBs and chlorinated
diphenyl ethers should be carried out by suitable chromatographic techniques (preferably with a
florisil, alumina and/or carbon column).
— Gaschromatographic separation of isomers should be sufficient (< 25 % peak to peak between
1,2,3,4,7,8-HxCDF and 1,2,3,6,7,8-HxCDF).
— Determination should be performed according to EPA Method 1613 revision B: tetra- through
octa-chlorinated dioxins and furans by isotope dilution HRGC/HRMS or another with equivalent
performance criteria.
— The difference between upperbound level and lower bound level should not exceed 20 % for
feedingstuffs with a dioxin contamination in the range or above the maximum level. For
feedingstuffs with contamination levels well below the maximum level, the difference may be in
the range of 25 % to 40 %.
Screening methods of analysis
7.1. Introduction
Different analytical approaches can be performed using a screening method: a pure screening
approach and a quantitative approach.
Screening approach
The response of samples is compared to that of a reference sample at the level of interest. Samples with
a response less than the reference are declared negative, those with a higher response are suspected
positives. Requirements
— a blank and a reference sample(s) have to be included in each test series, which is extracted and
tested at the same time under identical conditions. The reference sample must show a clearly
elevated response in comparison to a blank,
— additional reference samples at 0,5 × and 2 × the level of interest should be included to
demonstrate the proper performance of the test in the range of interest for the control of the level
of interest,
— when testing other matrices, the suitability of the reference sample(s) has to be demonstrated,
preferentially by including samples shown by HRGC/HRMS to contain a TEQ level around that of
the reference sample or else a blank spiked at this level,
— since no internal standards can be used in bioassays, tests on repeatability are very important to
obtain information on the standard deviation within one test series. The coefficient of variation
should be below 30 %,
— for bioassays, the target compounds, possible interferences, and maximum tolerable blank levels
should be defined.
Quantitative approach
The quantitative approach requires standard dilution series, duplicate or triplicate clean up and
measuring as well as blank and recovery controls. The result may be expressed as TEQ, thereby
assuming that the compounds responsible for the signal correspond to the TEQ principle. This can be
performed by using TCDD (or a dioxin/furan standard mixture) to produce a calibration curve to
calculate the TEQ level in the extract and thus in the sample. This is subsequently corrected for the
TEQ level calculated for a blank sample (to account for impurities from solvents and chemicals used),
and a recovery (calculated from the TEQ level in a quality control sample around the limit of interest).
It is essential to note that part of the apparent recovery loss may be due to matrix effects and/or
differences between the TEF values in the bioassays and the official TEF values set by WHO.
7.2. Requirements for methods of analysis used for screening
— GC/MS methods of analysis and bioassays may be used for screening. For GC/MS methods the
requirements as laid down in point 6 are to be used. For cell based bioassays specific requirements
are laid down in point 7.3 and for kit-based bioassays in point 7.4.
— Information on the number of false-positive and false-negative results of a large set of samples
below and above the maximum level or action level is necessary, in comparison to the TEQ
content as determined by a confirmatory method of analysis. Actual false negative rates should be
under 1 %. The rate of false positive samples should be low enough to make the use of a screening
tool advantageous.
— Positive results have always to be confirmed by a confirmatory method of analysis
(HRGC/HRMS). In addition, samples from a wide TEQ-range should be confirmed by
HRGC/HRMS (approximately 2 % to 10 % of the negative samples). Information on
correspondence between bioassay and HRGC/HRMS results should be made available.
7.3. Specific requirements for cell-based bioassays
— When performing a bioassay, every test run requires a series of reference concentration of TCDD
or a dioxin/furan mixture (full dose-response curve with a R2 > 0,95). However, for screening
purposes, an expanded low-level curve for analysing low-level samples could be used.
— A TCDD reference concentration (about three times the limit of quantification) on a quality control
sheet should be used for the outcome of the bioassay over a constant time period. An alternative
could be the relative response of a reference sample in comparison to the TCDD calibration line
since the response of the cells may depend on many factors.
— Quality control (QC) charts for each type of reference material should be recorded and checked to
make sure the outcome is in accordance with the stated guidelines.
— In particular for quantitative calculations, the induction of the sample dilution used must be within
the linear portion of the response curve. Samples above the linear portion of the response curve
must be diluted and re-tested. Therefore, at least three or more dilutions at one time are
recommended to be tested.
— The percent standard deviation should not be above 15 % in a triplicate determination for each
sample dilution and not above 30 % between three independent experiments.
— The limit of detection may be set as three times the standard deviation of the solvent blank or of
the background response. Another approach is to apply a response that is above the background
(induction factor five times the solvent blank) calculated from the calibration curve of the day. The
limit of quantification may be set as five to six times the standard deviation of the solvent blank or
of the background response or to apply a response that is clearly above the background (induction
factor 10 times the solvent blank) calculated from the calibration curve of the day.
7.4. Specific requirements for kit-based bioassays ( 1 )
— Manufacturer's instructions for sample preparation and analyses have to be followed.
— Test kits should not be used after the expiration date.
— Materials or components designed for use with other kits should not be used.
— Test kits should be kept within the specified range of storage temperature and used at the specified
operating temperature.
— The limit of detection for immunoassays is determined as the sum of the mean and three times the
standard deviation, based on 10 replicate analysis of the blank, to be divided by the slope value of
the linear regression equation.
— Reference standards should be used for tests at the laboratory to make sure that the responsiveness
to the standard is within an acceptable range.
Reporting of results
Insofar as the used analytical procedure makes it possible, the analytical results should contain the
levels of the individual PCDD/F and PCB congeners and be reported as lowerbound, upperbound
and mediumbound in order to include a maximum of information in the reporting of the results and
thereby enabling the interpretation of the results according to specific requirements.
The report should also include the lipid content of the sample as well the method used for lipid
extraction.
The recoveries of the individual internal standards must be made available in case the recoveries
are outside the range mentioned in point 6, in case the maximum level is exceeded and in the other
cases upon request.
No evidence have yet been submitted of commercially available kit-based bioassays having sufficient
sensitivity and reliability to be used for screening for the presence of dioxins at the required levels in samples
of foodstuffs and feedingstuffs.