L.N. 488 of 2004
FOOD SAFETY ACT
(CAP. 449)
Contaminants in Food (Sampling and Analysis Methods)
Regulations, 2004
IN exercise of the powers conferred by article 10 of the Food Safety
Act, the Minister of Health, the Elderly and Community Care has made
the following regulations
1 The title of these regulations is the Contaminants in Food Title
(Sampling and Analysis Methods) Regulations, 2004.
1.2
These regulations implement the provisions of
(a) Commission Directive 98/53/EC of the 16 th July, 1998
laying down the sampling methods and the methods of analysis
for the official control of the levels for certain contaminants in
foodstuffs;
(b) Commission Directive 2002/26/EC of the 13 th March,
2002 amending Directive 98/53/EC laying down the sampling
methods and the methods of analysis for the official control of the
levels for certain contaminants in foodstuffs;
(c) Commission Directive 2002/27/EC of the 13 th March,
2002 amending Directive 98/53/EC laying down the sampling
methods and the methods of analysis for the official control of the
levels for certain contaminants in foodstuffs;
(d) Commission Directive 2003/121/EC of 15 th December,
2003 amending Directive 98/53/EC laying down the sampling
methods and the methods of analysis for the official control of the
levels for certain contaminants in foodstuffs;
(e) Commission Directive 2004/43/EC of 13 th April, 2004
amending Directive 98/53/EC and Directive 2002/26/EC as regards
sampling methods and methods of analysis for the official control
of the levels of aflatoxin and ochratoxin A in food for infants and
young children;
(f) Commission Directive 2001/22/EC of 8 th March, 2001
laying down the sampling methods and the methods of analysis
for the official control of the levels of lead, cadmium, mercury
and 3-MCPD in foodstuffs;
(g) Commission Directive 2002/69/EC of 26 th July, 2002
laying down the sampling methods and the methods of analysis
for the official control of dioxins and the determination of dioxin-
like PCBs in foodstuffs;
(h) Commission Directive 2004/44/EC of 13 th April, 2004
amending Directive 2002/69/EC laying down the sampling
methods and the methods of analysis for the official control of
dioxins and the determination of dioxin-like PCBs in foodstuffs
(i) Commission Directive 2002/26/EC of 13 th March, 2002
laying down the sampling methods and the methods of analysis
for the official control of the levels of ochratoxin A in foodstuffs;
(j) Commission Directive 2003/78/EC of 11 th August, 2003
laying down the sampling methods and the methods of analysis
for the official control of the levels of patulin in foodstuffs.
(Equivalent to Annex I of Commission Directive 98/53/EC)
Methods of sampling for official checking control of the levels of aflatoxins in
certain foodstuffs
1. Purpose and scope
Samples intended for official checking of the levels of aflatoxin content in
foodstuffs shall be taken according to the methods described below. Aggregate
samples thus obtained shall be considered as representative of the lots.
Compliance with maximum limits laid down in Commission Regulation (EC) No
1525/98 shall be established on the basis of the levels determined in the
laboratory samples.
2. Definitions
Lot: an identifiable quantity of a food commodity delivered at one time and
determined by the official to have common characteristics, such as origin, variety,
type of packing, packer, consignor or markings.
Sublot: designated part of a large lot in order to apply the sampling method on
that designated part. Each sublot must be physically separate and identifiable.
Incremental sample: a quantity of material taken from a single place in the lot or
sublot.
Aggregate sample: the combined total of all the incremental samples taken from
the lot or sublot.
Laboratory sample: sample intended for the laboratory (=subsample).
3. General provisions
Personnel
Sampling shall be performed by an official analyst as specified by the Act.
Material to be sampled
Each lot which is to be examined must be sampled separately. In accordance with
the specific provisions in point 5 of this Schedule, large lots should be subdivided
into sublots to be sampled separately.
Precautions to be taken
In the course of sampling and preparation of the laboratory samples precautions
must be taken to avoid any changes which would affect the aflatoxin content,
adversely affect the analytical determination or make the aggregate samples
unrepresentative.
Incremental samples
B
As far as possible incremental samples should be taken at various places
distributed throughout the lot or sublot. Departure from this procedure must be
recorded in the record provided for in 3.8.
Preparation of the aggregate sample and the laboratory samples (subsamples)
The aggregate sample is made up by uniting and sufficiently mixing the
incremental samples. After mixing, the aggregate sample must be divided into
equal subsamples in accordance with the specific provisions of point 5 of this
Schedule. The mixing is necessary to ensure that each subsample contains
portions of the whole lot or sublot.
Replicate samples
The replicate samples for enforcement, trade (defence) and referee purposes are to
be taken from the homogenised laboratory sample.
Packaging and transmission of laboratory samples
Each laboratory sample shall be placed in a clean, inert container offering
adequate protection from contamination and against damage in transit. All
necessary precautions shall be taken to avoid any change in composition of the
laboratory sample which might arise during transportation or storage.
Sealing and labelling of laboratory samples
Each sample taken for official use shall be sealed at the place of sampling and
identified. A record must be kept of each sampling, permitting each lot to be
identified unambiguously and giving the date and place of sampling together with
any additional information likely to be of assistance to the analyst.
4. Explanatory provisions
Different types of lots
Food commodities may be traded in bulk, containers, or individual packings
(sacks, bags, retail packings, etc.). The sampling procedure can be applied to all
the different forms in which the commodities are put on the market. Without
prejudice to the specific provisions as laid down in point 5 of this Schedule, the
following formula can be used as a guide for the sampling of lots traded in
individual packings (sacks, bags, retail packings, etc.)
Sampling frequency (SF) = {Weight of the lot} x {Weight of the incremental sample}/{Weight of
the aggregate sample} x {Weight of individual packing}
–
Weight: in kg
–
Sampling frequency (SF): every nth sack or bag from which an
incremental sample must be taken (decimal figures should be rounded to
the nearest whole number).
Weight of the incremental sample
The weight of the incremental sample should be about 300 grams unless
otherwise defined in point 5 of this Schedule and with the exception of spices in
which case the weight of the incremental sample is about 100 grams. In the case
of retail packings, the weight of the incremental sample depends on the weight of
the retail packing.
Number of incremental samples for lots of less than 15 tonnes
The number of incremental samples to be taken depends on the weight of the lot,
with a minimum of 10 and a maximum of 100, unless otherwise defined in point 5
of this Schedule. The figures in the following table may be used to determine the
number of incremental samples to be taken.
Table 1: Number of incremental samples to be taken depending on the weight of
the lot
Lot weight
No of incremental samples
(tonnes)
≤ 0.1
> 0.1 - ≤ 0.2
> 0.2 - ≤ 0.5
> 0.5 - ≤ 1.0
> 1.0 - ≤ 2.0
> 2.0 - ≤ 5.0
> 5.0 - ≤ 10.0
> 10.0 - ≤ 15.0
5. Specific provisions
General survey of the sampling procedure for groundnuts, nuts, dried fruit, spices
and cereals
Table 2: Subdivision of lots into sublots depending on product and lot weight
Commodity
Lot weight
Weight or
Number of
Aggregate
(tonnes)
number of
incremental
sample weight
sublots
samples
(kg)
≥ 15
Dried figs and other dried fruit
15-30 tonnes
10-100 ( * )
≤ 30
-
< 15
≥ 500
Groundnuts, pistachios, Brazil
100 tonnes
nuts and other nuts
5 sublots
> 125 & < 500
25 tonnes
≥ 15 & ≤ 125
10-100 ( * )
≤ 30
-
< 15
≥ 1500
Cereals
500 tonnes
3 sublots
> 300 & < 1500
100 tonnes
≥ 50 & ≤ 300
10-100 ( * )
-
1-10
< 50
Depending on the lot weight – see point 4.3 or 5.3 of this Schedule
B
Commodity
Lot weight
Weight or
Number of
Aggregate
(tonnes)
number of
incremental
sample weight
sublots
samples
(kg)
≥ 15
25 tonnes
-
10-100 (*)
1-10
< 15
Groundnuts, pistachios and Brazil nuts
Dried figs
Cereals (lots ≥ 50 tonnes)
Spices
5.2.1. Sampling procedure
On condition that the sublot can be separated physically, each lot must be
subdivided into sublots following Table 2 at point 5.1. Taking into account
that the weight of the lot is not always an exact multiple of the weight of
the sublots, the weight of the sublot may exceed the mentioned weight by
a maximum of 20 %,
each sublot must be sampled separately,
number of incremental samples: 100. In the case of lots under 15 tonnes,
the number of incremental samples to be taken depends on the weight of
the lot, with a minimum of 10 and a maximum of 100 (see point 4.3),
weight of the aggregate sample = 30 kg which has to be mixed and to be
divided into three equal subsamples of 10 kg before grinding (this division
into three subsamples is not necessary in the case of groundnuts, nuts,
dried fruit and maize intended for further sorting or other physical
treatment, however, this will depend upon the availability of equipment
which is able to homogenise a 30 kg sample). In cases where the aggregate
sample weights are under 10 kg, the aggregate sample must not be divided
into three subsamples. In the case of spices the aggregate sample weighs
not more than 10 kg and therefore no division in subsamples is necessary.
laboratory sample: a subsample of 10 kg (each subsample must be
separately ground finely and mixed thoroughly to achieve complete
homogenisation, in accordance with the provisions laid down in the
Second Schedule),
if it is not possible to carry out the method of sampling described above
because of the commercial consequences resulting from damage to the lot
(because of packaging forms, means of transport, etc.) an alternative
method of sampling may be applied provided that it is as representative as
possible and is fully described and documented.
5.2.2. Acceptance of a lot or sublot
For groundnuts, nuts, dried fruit and maize subjected to a sorting or other
physical treatment and spices
acceptance if the aggregate sample or the average of the
subsamples conforms to the maximum limit, taking into account
the measurement uncertainty and correction for recovery,
rejection if the aggregate sample or the average of the subsamples
exceeds the maximum limit beyond reasonable doubt, taking into
account the measurement uncertainty and correction for recovery.
for groundnuts, nuts, dried fruit and cereals intended for direct human
consumption and cereals, with the exception of maize, to be subjected to a
sorting or other physical treatment
acceptance if none of the subsamples exceeds the maximum limit,
taking into account the measurement uncertainty and correction for
recovery,
rejection if one or more of the subsamples exceeds the maximum
limit beyond reasonable doubt, taking into account the
measurement uncertainty and correction for recovery.
where the aggregate sample is under 10 kg
acceptance if the aggregate sample conforms to the maximum
limit, taking into account the measurement uncertainty and
correction for recovery,
rejection if the aggregate sample exceeds the maximum limit
beyond reasonable doubt, taking into account the measurement
uncertainty and correction for recovery.
Nuts other than groundnuts, pistachios and Brazil nuts
Dried fruit other than figs
Cereals (lots under 50 tonnes)
5.3.1. Sampling procedure
For these products, the sampling procedure laid down in point 5.2.1 may be
applied. However, taking into account the low incidence of contamination for
these products and/or the newer forms of packaging in which products can be
traded, simpler sampling methods may be applied. For cereal lots under 50
tonnes, a sampling plan consisting of, depending on the lot weight, 10 to 100
incremental samples each of 100 grams, resulting in an aggregate sample of 1 to
10 kg may be used. The figures in the following table can be used to determine
the number of incremental samples to be taken.
Table 3: Number of incremental samples to be taken depending on the weight of the lot of
cereals
Lot weight
Number of incremental samples
(tonnes)
≤ 1
> 3 - ≤ 10
> 10 - ≤ 20
> 20 - ≤ 50
B
5.3.2. Acceptance of a lot or sublot
See point 5.2.2.
5.4.1. Sampling procedure
Sampling in accordance with Commission Decision 91/180/EEC of 14 February
1991 laying down certain methods of analysis and testing of raw milk and heat-
treated milk 1
number of incremental samples: minimum 5,
weight of aggregate sample: minimum 0,5 kg or litres.
5.4.2. Acceptance of a lot or sublot
Acceptance if the aggregate sample conforms to the maximum limit,
taking into account the measurement uncertainty and correction for
recovery,
rejection if the aggregate sample exceeds the maximum limit beyond
reasonable doubt taking into account the measurement uncertainty and
correction for recovery.
Derived products and compound foods
5.5.1. Milk products
5.5.1.1. Sampling procedure
Sampling in accordance with Commission Directive 87/524/EEC of 6 October
1987 laying down Community methods of sampling for chemical analysis for the
monitoring of preserved milk products 2 .
Number of incremental samples: minimum 5.
For the other milk products an equivalent method of sampling is used.
5.5.1.2. Acceptance of a lot or sublot
Acceptance if the aggregate sample conforms to the maximum limit,
taking into account the measurement uncertainty and correction for
recovery,
rejection if the aggregate sample exceeds the maximum limit beyond
reasonable doubt taking into account the measurement uncertainty and
correction for recovery.
OJ L 93, 13. 4. 1991, p. 1.
OJ L 306, 28. 10. 1987, p. 24.
5.5.2. Other derived products with very small particle weight, i.e. flour, fig paste, peanut
butter (homogeneous distribution of aflatoxin contamination)
5.5.2.1. Sampling procedure
Number of incremental samples: 100. For lots of under 50 tonnes the
number of incremental samples should be 10 to 100, depending on the lot
weight (see Table 3 at point 5.3.1 of this Schedule),
the weight of the incremental sample should be about 100 grams. In the
case of lots in retail packing, the weight of the incremental sample
depends on the weight of the retail packing,
weight of aggregate sample = 1-10 kg sufficiently mixed.
5.5.2.2. Number of samples to be taken
The number of aggregate samples to be taken depends on the lot weight.
The division of large lots into sublots must be done as defined for cereals
in Table 2 under point 5.1,
each sublot must be sampled separately.
5.5.2.3 Acceptance of a lot or sublot
Acceptance if the aggregate sample conforms to the maximum limit,
taking into account the measurement uncertainty and correction for
recovery,
rejection if the aggregate sample exceeds the maximum limit beyond
reasonable doubt taking into account the measurement uncertainty and
correction for recovery.
Other derived products with a relatively large particle size (heterogeneous
distribution of aflatoxin contamination)
Sampling procedure and acceptance as defined at points 5.2 and 5.3 of this
Schedule for the raw agricultural product.
Foods intended for infants and young children
Sampling procedure
The sampling procedure as mentioned for milk and derived products as well as for
compounded food in points 5.4, 5.5 and 5.6 applies.
Acceptance of a lot
Acceptance if the aggregate sample conforms to the maximum limit, taking
into account the measurement uncertainty and correction for recovery,
Rejection if the aggregate sample exceeds the maximum limit beyond
reasonable doubt, taking into account the measurement uncertainty and
correction for recovery.
B
6. Sampling at retail stage
Sampling of foodstuffs at the retail stage should be done where possible in
accordance with the above sampling provisions. Where this is not possible, other
effective sampling procedures at retail stage can be used provided that they ensure
sufficient representativeness for the sampled lot.
1 The sampling for the official control of the levels of aflatoxins
in foodstuffs shall be carried out in accordance with the methods
described in the First Schedule to these regulations.
2.2 The sample preparation and methods of analyses used for
the official control of the levels of aflatoxins in foodstuffs shall comply
with the criteria described in the Second Schedule to these regulations.
(Equivalent to Annex II of Commission Directive 98/53/EC)
Sample preparation and criteria for methods of analysis used in official checking of
the levels of aflatoxins in certain foodstuffs
1. Introduction
Precautions
Daylight should be excluded as much as possible during the procedure, since
aflatoxin gradually breaks down under the influence of ultra-violet light. As the
distribution of aflatoxin is extremely non-homogeneous, samples should be
prepared – and especially homogenised – with extreme care. All the material
received by the laboratory is to be used for the preparation of test material.
Calculation of proportion of shell/kernel of whole nuts
The limits fixed for aflatoxins in the Contaminants in Food Regulations apply to
the edible part. The level of aflatoxins in the edible part can be determined by
shelling samples of nuts `in shell' and the level of aflatoxins is directly
determined in the edible part,
homogenise the nuts `in shell' by taking them through the sample
preparation procedure. The sampling and analytical procedure must
estimate the weight of nut kernel in the aggregate sample. The weight of
nut kernel in the aggregate sample is estimated after establishing a suitable
factor for the proportion of nut shell to nut kernel in whole nuts. This
proportion is used to ascertain the amount of kernel in the bulk sample
taken through the sample preparation and analysis procedure.
Approximately 100 whole nuts are taken at random separately from the lot
or are to be put aside from each aggregate sample. The ratio may, for each
laboratory sample, be obtained by weighing the whole nuts, shelling and
re-weighing the shell and kernel portions. However, the proportion of shell
to kernel may be established by the laboratory from a number of samples
and so can be assumed for future analytical work. But if a particular
laboratory sample is found to be in contravention of any limit, the
proportion should be determined for that sample using the approximately
100 nuts that have been set aside.
2. Treatment of the sample as received in the laboratory
Finely grind and mix thoroughly each laboratory sample using a process that has
been demonstrated to achieve complete homogenisation.
B
In case the maximum level applies to the dry matter, the dry matter content shall
be determined on a part of the homogenised sample, using a procedure that has
been demonstrated to determine accurately the dry matter content.
3. Subdivision of samples for enforcement and defence purposes
The replicate samples for enforcement, trade (defence) and referee purposes shall
be taken from the homogenized material.
4. Method of analysis to be used by the laboratory and laboratory control
requirements
Definitions
A number of the most commonly used definitions that the laboratory will be
required to use are given below
The most commonly quoted precision parameters are repeatability and
reproducibility.
r = repeatability, the value below which the absolute difference between two
single test results obtained under repeatability conditions (i. e. same sample, same
operator, same apparatus, same laboratory, and short interval of time) may be
expected to lie within a specific probability (typically 95 %) and hence r = 2.8 . s r
s r = Standard deviation, calculated from results generated under repeatability
conditions
RSD r = relative standard deviation, calculated from results generated under
repeatability conditions [(S r /x) . 100], where x is the average of results over all
laboratories and samples
R = reproducibility, the value below which the absolute difference between single
test results obtained under reproducibility conditions (i.e. on identical material
obtained by operators in different laboratories, using the standardised test method)
may be expected to lie within a certain probability (typically 95 %); R = 2.8 s R
s R = standard deviation, calculated from results under reproducibility conditions
RSD R = relative standard deviation calculated from results generated under
reproducibility conditions [(S R /x).100]
General requirements
Methods of analysis used for food control purposes must comply whenever
possible with the provisions of points 1 and 2 of the Annex to Council Directive
85/591/EEC.
Specific requirements
Where no specific methods for the determination of aflatoxin levels in foodstuffs
are prescribed at Community level, laboratories may select any method provided
the selected method meets the following criteria
Criterion
Concentration range
Recommended value
Maximum permitted
value
All
Negligible
0.01 – 0.05 µg/kg
Recovery – Aflatoxin
60 to120 %
70 to 110 %
> 0.05 µg/kg
< 1.0 µg/kg
Recovery – Aflatoxins
50 to 120 %
70 to110 %
1-10 µg/kg
80 to 110 %
> 10 µg/kg
Precision RSD R
All
As derived from
2 x value derived from
Horwitz equation
Horwitz equation
Precision RSD R may be calculated as 0.66 times precision RSD R at the
concentration of interest.
Notes
Values to apply to both B 1 and sum of B 1 +B 2 +G 1 +G 2 ,
if sum of individual aflatoxins B 1 +B 2 +G 1 +G 2 are to be reported, then response of
each to the analytical system must be either known or equivalent,
the detection limits of the methods used are not stated as the precision values are
given at the concentrations of interest,
the precision values are calculated from the Horwitz equation, i. e.
RSD R = 2 (1-0,5 logC)
where
–
RSD R is the relative standard deviation calculated from results generated
under reproducibility conditions [(S R /x) .100]
–
C is the concentration ratio (i. e. 1 = 100 g/100 g, 0,001 = 1 000 mg/kg).
This is a generalised precision equation which has been found to be independent
of analyte and matrix but solely dependent on concentration for most routine
methods of analysis.
Recovery calculation
The analytical result is to be reported corrected or uncorrected for recovery. The
manner of reporting and the level of recovery must be reported. The analytical
B
result corrected for recovery is used for checking compliance (see First Schedule,
points 5.2.2, 5.3.2, 5.4.2, 5.5.1.2 and 5.5.2.3.
The analytical result has to be reported as x ± U whereby x is the analytical result
and U is the expanded measurement uncertainty, using a coverage factor of 2
which gives a level confidence of approximately 95 %.
Laboratory quality standards
Laboratories must comply with Council Directive 93/99/EEC.
1 The sampling for the official control of the levels of lead,
cadmium, mercury and 3-MCPD in foodstuffs shall be carried out in
accordance with the methods described in the Third Schedule to these
regulations.
3.2 The sample preparation and methods of analyses used for
the official control of the levels of lead, cadmium, mercury and 3-MCPD
in foodstuffs shall comply with the criteria described in the Fourth
Schedule to these regulations.
(Equivalent to Annex I of Commission Directive 2001/22/EC)
Methods Of Sampling For Offical Control Of The Levels Of Lead, Cadmium,
Mercury And 3-MPCD In Certain Foodstuffs
1. PURPOSE AND SCOPE
Samples intended for the official control of the levels of lead, cadmium, mercury
and 3-MCPD contents in foodstuffs shall be taken according to the methods
described below. Aggregate samples thus obtained shall be considered as
representative of the lots or sublots from which they are taken. Compliance with
maximum levels laid down in the Contaminants in Food Regulations shall be
established on the basis of the levels determined in the laboratory samples.
2. DEFINITIONS
Lot: an identifiable quantity of food delivered at one time and determined by the
official to have common characteristics, such as origin, variety, type of packing,
packer, consignor or markings. In the case of fish, also the size of fish shall be
comparable.
Sublot: designated part of a large lot in order to apply the sampling method on
that designated part. Each sublot must be physically separated and identifiable.
Incremental sample: a quantity of material taken from a single place in the lot or
sublot.
Aggregate sample: the combined total of all the incremental samples taken from
the lot or sublot.
Laboratory sample: sample intended for the laboratory
3. GENERAL PROVISIONS
Personnel
Sampling shall be performed by an authorised analyst as specified by the Act.
Material to be sampled
Each lot which is to be examined must be sampled separately.
Precautions to be taken
In the course of sampling and preparation of laboratory samples precautions must
be taken to avoid any changes which would affect the lead, cadmium, mercury
and 3-MCPD contents, adversely affect the analytical determination or make the
aggregate samples unrepresentative.
B
Incremental samples
As far as possible incremental samples shall be taken at various places distributed
throughout the lot or sublot. Departure from this procedure must be recorded in
the record provided for under 3.8.
Preparation of the aggregate sample
The aggregate sample is made up by uniting all incremental samples. It shall be at
least 1 kg unless not practical, e.g. when a single package has been sampled.
Subdivision of aggregate sample in laboratory samples for enforcement,
defence and referee purposes
The laboratory samples for enforcement, trade (defence) and referee purposes
shall be taken from the homogenised aggregate sample. The size of the laboratory
samples for enforcement shall be sufficient to allow at least for duplicate
analyses.
Packaging and transmission of aggregate and laboratory samples
Each aggregate and laboratory sample shall be placed in a clean, inert container
offering adequate protection from contamination, from loss of analytes by
adsorption to the internal wall of the container and against damage in transit. All
necessary precautions shall be taken to avoid change of composition of the
aggregate and laboratory samples which might arise during transportation or
storage.
Sealing and labelling of aggregate and laboratory samples
Each sample taken for official use shall be sealed at the place of sampling and
identified. A record must be kept of each sampling, permitting each lot to be
identified unambiguously and giving the date and place of sampling together with
any additional information likely to be of assistance to the analyst.
4. SAMPLING PLANS
Sampling should ideally take place at the point where the commodity enters the
food chain and a discrete lot becomes identifiable. The sampling method applied
shall ensure that the aggregate sample is representative for the lot that is to be
controlled.
Number of incremental samples
In the case of liquid products for which a homogeneous distribution of the
contaminant in question can be assumed within a given lot, it is sufficient to take
one incremental sample per lot which forms the aggregate sample. Reference to
the lot number shall be given. Liquid products containing hydrolysed vegetable
protein (HVP) or liquid soya sauce shall be shaken well, or homogenised by other
suitable means, before the incremental sample is taken. For other products, the
minimum number of incremental samples to be taken from the lot shall be as
given in Table 1. The incremental samples shall be of similar weight. Departure
from this procedure must be recorded in the record provided for under 3.8.
Table 1: Minimum number of incremental samples to be taken from the lot
Weight of lot
Minimum number of incremental samples to be
(kg)
taken
< 50
50 to 500
> 500
If the lot consists of individual packages, then the number of packages which shall
be taken to form the aggregate sample is given in Table 2.
Table 2: Number of packages (incremental samples) which shall be taken to form the
aggregate sample if the lot consists of individual packages
Number of packages or units in the lot
Number of packages or units to be taken
1 to 25
1 package or unit
26 to 100
About 5 %, at least 2 packages or units
> 100
About 5 % at maximum 10 packages or units
5. COMPLIANCE OF THE LOT OR SUBLOT WITH THE SPECIFICATION
The control laboratory shall analyse the laboratory sample for enforcement at
least in two independent analyses, and calculate the mean of the results. The lot is
accepted if the mean conforms to the respective maximum level as laid down in
the Contaminants in Food Regulations. It is rejected if the mean exceeds the
respective maximum level.
B
1 The sampling for the official control of the levels of
ochratoxin A in foodstuffs shall be carried out in accordance with the
methods described in the Fifth Schedule to these regulations.
4.2 The sample preparation and methods of analyses used for
the official control of the levels of ochratoxin A in foodstuffs shall
comply with the criteria described in the Sixth Schedule to these
regulations.
(Equivalent to Annex II of Commission Directive 2001/22/EC)
Sample Preparation And Criteria For Methods Of Analysis Used In Offical Control
Of The Levels Of Lead, Cadmium, Mercury And 3-MCPD In Certain Foodstuffs
1. INTRODUCTION
The basic requirement is to obtain a representative and homogeneous laboratory
sample without introducing secondary contamination.
2. SPECIFIC SAMPLE PREPARATION PROCEDURES FOR LEAD, CADMIUM
AND MERCURY
There are many satisfactory specific sample preparation procedures which may be
used for the products under consideration. Those described in the draft CEN
Standard ‘Foodstuffs — Determination of trace elements — Performance criteria
and general consideration’ have been found to be satisfactory ( 3 ) but others may
be equally valid.
The following points must be noted for any procedure used
—
bivalve molluscs, crustaceans and small fish: where these are normally
eaten whole, the viscera are to be included in the material to be analysed,
—
vegetables: only the edible portion of is to be tested, with note to be taken
of the requirements of the Contaminants in Food Regulations.
3. METHOD OF ANALYSIS TO BE USED BY THE LABORATORY AND
LABORATORY CONTROL REQUIREMENTS
Definitions
A number of the most commonly used definitions that the laboratory will be
required to use are given below
r = repeatability, the value below which the absolute difference between two
single test results obtained under repeatability conditions (i.e., same sample, same
operator, same apparatus, same laboratory, and short interval of time) may be
expected to lie within a specific probability (typically 95 %) and hence r = 2.8 . s r .
s r = standard deviation, calculated from results generated under repeatability
conditions.
RSD r = relative standard deviation, calculated from results generated under
repeatability conditions [( s r / x ) × 100 ] , where x is the average of results over all
laboratories and samples.
Draft Standard prEN 13804, ‘Foodstuffs — Determination of Trace Elements — Performance Criteria
and General Considerations’, CEN, Rue de Stassart 36, B-1050 Brussels.
R = reproducibility, the value below which the absolute difference between single
test results obtained under reproducibility conditions (i.e., on identical material
obtained by operators in different laboratories, using the standardised test
method), may be expected to lie within a certain probability (typically 95 %); R =
2.8 . s R .
s R = standard deviation, calculated from results under reproducibility conditions.
RSD R = relative standard deviation calculated from results generated under
reproducibility conditions [( s R / x ) × 100 ]
HORRAT r = the observed RSD r divided by the RSD r value estimated from the
Horwitz equation using the assumption r = 0,66R
HORRAT R = the observed RSD R value divided by the RSD R value calculated
from the Horwitz equation ( 4 ).
General requirements
Methods of analysis used for food control purposes must comply whenever
possible with the provisions of paragraphs 1 and 2 of the Annex to Directive
85/591/EEC of the European Community. For the analysis of lead in wine,
Commission Regulation (EEC) No 2676/90( 5 ) determining Community methods
for the analysis of wines lays down the method to be used in Chapter 35 of its
Annex.
Specific requirements
3.3.1. Lead, cadmium and mercury analyses
Specific methods for the determination of lead, cadmium and mercury contents
are not prescribed. Laboratories shall use a validated method that fulfils the
performance criteria indicated in Table 3. Where possible, the validation shall
include a certified reference material in the collaborative trial test materials.
Table 3: Performance criteria of methods for lead, cadmium and mercury analyses
Parameter
Value/comment
Applicability
Foods specified in the Contaminants in Food
Regulations
Detection limit
No more than one tenth of the value of the
specification in the Contaminants in Food
Regulations, except if the value of the specification
W Horwitz, ‘Evaluation of Analytical Methods for Regulation of Foods and Drugs’, Anal. Chem., 1982,
No 54, 67A-76A
OJ L 272, 3.10.1990, p. 1.
B
Parameter
Value/comment
for lead is less than 0.1 mg/kg. For the latter, no
more than one fifth of the value of the specification
Limit of quantification
No more than one fifth of the value of the
specification in the Contaminants in Food
Regulations, except if the value of the specification
for lead is less than 0.1 mg/kg. For the latter, no
more than two fifths of the value of the specification
Precision
HORRAT r or HORRAT R values of less than 1.5 in
the validation collaborative trial
Recovery
80-120 % (as indicated in the collaborative trial)
Specificity
Free from matrix or spectral interferences
3.3.2. 3-MCPD analysis
Specific methods for the determination of 3-MCPD contents are not prescribed.
Laboratories shall use a validated method that fulfils the performance criteria
indicated in Table 4. Where possible, the validation shall include a certified
reference material in the collaborative trial test materials. A specific method has
been validated by collaborative trial and has been shown to meet the requirements
of Table 4 ( 6 ).
Table 4: Performance criteria of methods for 3-MCPD analysis
Criterion
Recommended value
Concentration
Field blanks
Less than the detection limit
-
Recovery
75 – 110 %
All
10 (or less) µg on a dry matter
Limit of quantification
-
basis
Less than 4 µg/kg
Standard deviation of the field
-
blank signal
< 4 µg/kg
20 µg/kg
In-house precision estimates –
standard deviation of replicate
< 6 µg/kg
30 µg/kg
measurements at different
< 7 µg/kg
40 µg/kg
concentrations
< 8 µg/kg
50 µg/kg
< 15 µg/kg
100 µg/kg
Estimation of the analytical trueness and recovery calculations
Wherever possible the trueness of the analysis shall be estimated by including
suitable certified reference materials in the analytical run. The ‘Harmonised
Guidelines for the Use of Recovery Information in Analytical Measurement’ ( 7 )
Method of Analysis to determine 3-Monochloropropane-1,2-Diol in Food and Food Ingredients using
Mass Spectrometric Detection, submitted to CEN TC 275 and AOAC International (also available as
‘Report of the Scientific Cooperation task 3.2.6: Provision of validated methods to support the Scientific
Committee on Food’s recommendations regarding 3-MCPD in hydrolysed protein and other foods’).
ISO/AOAC/IUPAC Harmonised Guidelines for the Use of Recovery Information in Analytical
Measurement. Edited Michael Thompson, Steven L R Ellison, Ales Fajgelj, Paul Willetts and Roger Wood,
Pure Appl. Chem., 1999, No 71, 337-348
developed under the auspices of IUPAC/ISO/AOAC shall be taken into account.
The analytical result shall be reported corrected or uncorrected. The manner of
reporting and the level of recovery must be reported.
Laboratory quality standards
Laboratories must comply with Directive 93/99/EEC.
Expression of results
The results shall be expressed in the same units as the maximum levels laid down
in the Contaminants in Foods Regulations.
B
1 The sampling for the official control of the levels of dioxins Sampling and
and furans and the determination of the levels of dioxin-like PCBs in analytical
for dioxins and
foodstuffs shall be carried out in accordance with the methods described dioxin-like PCBs in
foodstuffs.
in the Seventh Schedule to these regulations.
5.2 The sample preparation and methods of analyses used for
the official control of the levels of dioxins and furans and the
determination of the levels of dioxin-like PCBs in foodstuffs shall
comply with the criteria described in the Eighth Schedule to these
regulations.
(Equivalent to Annex I of Commission Directive 2002/26/EC)
Methods of Sampling for Official Control of the Levels of Ochratoxin A in certain
foodstuffs
1. Purpose and scope
Samples intended for official checking of the levels of ochratoxin A content in foodstuffs
shall be taken according to the methods described below. Aggregate samples thus
obtained shall be considered as representative of the lots. Compliance with maximum
limits laid down in Regulation (EC) No 466/2001 shall be established on the basis of the
levels determined in the laboratory samples.
2. Definitions
Lot
an identifiable quantity of a food commodity delivered at one time
and determined by the official to have common characteristics,
such as origin, variety, type of packing, packer, consignor or
markings.
Sublot
designated part of a lot in order to apply the sampling method on
that designated part. Each sublot must be physically separate and
identifiable.
Incremental sample: a quantity of material taken from a single place in the lot or sublot
Aggregate sample
the combined total of all the incremental samples taken from the
lot or sublot.
3. General provisions
3.1. Personnel
Sampling shall be performed by an authorised person as specified by the Food Safety
Commission.
3.2. Material to be sampled
Each lot which is to be examined must be sampled separately. In accordance with the
specific provisions of this Schedule, large lots should be subdivided into sublots to be
sampled separately.
3.3. Precautions to be taken
In the course of sampling and preparation of the samples precautions must be taken to
avoid any changes which would affect the ochratoxin A content, adversely affect the
analytical determination or make the aggregate samples unrepresentative.
3.4. Incremental samples
As far as possible incremental samples should be taken at various places distributed
throughout the lot or sublot. Departure from this procedure must be recorded in the
record.
3.5. Preparation of the aggregate sample
The aggregate sample is made up by uniting the incremental samples.
3.6. Replicate samples
The replicate samples for enforcement, trade (defence) and referee purposes are to be
taken from the homogenised sample, unless this conflicts with other applicable rules on
sampling.
3.7. Packaging and transmission of samples
Each sample shall be placed in a clean, inert container offering adequate protection from
contamination and against damage in transit. All necessary precautions shall be taken to
avoid any change in composition of the sample, which might arise during transportation
or storage.
3.8. Sealing and labelling of samples
Each sample taken for official use shall be sealed at the place of sampling and identified
following appropriate procedures established by the Food Safety Commission. A record
must be kept of each sampling, permitting each lot to be identified unambiguously and
giving the date and place of sampling together with any additional information likely to
be of assistance to the analyst.
4. Specific provisions
4.1. Different types of lots
Food commodities may be traded in bulk, containers, or individual packings (sacks, bags,
retail packings, etc.). The sampling procedure can be applied to all the different forms in
which the commodities are put on the market.
Without prejudice to the specific provisions as laid down in points 4.3, 4.4 and 4.5 of this
Schedule, the following formula can be used as a guide for the sampling of lots traded in
individual packings (sacks, bags, retail packings, etc.)
Sampling frequency (SF) n = Weight of the lot . Weight of the incremental sample
Weight of the aggregate sample . Weight of individual packaging
—
Weight: in kg
—
Sampling Frequency (SF): every nth sack or bag from which an incremental
sample must be taken (decimal figures should be rounded to the nearest whole
number).
4.2. Weight of the aggregate sample
B
The weight of the incremental sample should be about 100 grams, unless otherwise
defined in this Schedule. In the case of lots in retail packings, the weight of the
incremental sample depends on the weight of the retail packing.
4.3. General survey of the sampling procedure for cereals and dried vine fruit
Table 1: Subdivision of lots into sublots depending on product and lot weight
Commodity
Lot weight
Weight or
Number of
Aggregate
(tonnes)
number of
incremental
sample
sublots
samples
Weight
(kg)
Cereals
and
cereal ≥ 1500
500 tonnes
products
> 300 and <
3 sublots
≥ 50 and ≤
100 tonnes
10-100 ( 8 )
< 50
-
1-10
vine
fruit ≥ 15
15–30 tonnes
(currants, raisins and
10-100 ( 9 )
< 15
-
1-10
sultanas)
4.4. Sampling procedure for cereals and cereal products (lots ≥ 50 tonnes) and dried
vine fruit (lots ≥ 15 tonnes)
On condition that the sublot can be separated physically, each lot must be
subdivided into sublots following Table 1. Taking into account that the weight of
the lot is not always an exact multiple of the weight of the sublots, the weight of
the sublot may exceed the mentioned weight by a maximum of 20 %.
Each sublot must be sampled separately.
Number of incremental samples: 100. In the case of lots of cereals under 50
tonnes and lots of dried vine fruit under 15 tonnes, see point 4.5. Weight of the
aggregate sample = 10 kg.
If it is not possible to carry out the method of sampling described above because
of the commercial consequences resulting from damage to the lot (because of
packaging forms, means of transport, etc.) an alternative method of sampling may
be applied provided that it is as representative as possible and is fully described
and documented.
4.5. Sampling provisions for cereals and cereal products (lots < 50 tonnes) and for dried
vine fruit (lots < 15 tonnes)
Depending on the lot weight – See Table 2 of this Schedule.
Depending on the lot weight – See Table 3 of this Schedule.
For cereal lots under 50 tonnes and for dried vine fruit lots under 15 tonnes, the sampling
plan has to be used with 10 to 100 incremental samples, depending on the lot weight,
resulting in an aggregate sample of 1 to 10 kg.
The figures in the following table can be used to determine the number of incremental
samples to be taken.
Table 2: Number of incremental samples to be taken depending on the weight of the lot of
cereals
Lot weight
Number of incremental samples
(tonnes)
≤ 1
>3 - ≤ 10
> 10 - ≤ 20
> 20 - ≤ 50
Table 3: Number of incremental samples to be taken depending on the weight of the lot of
dried vine fruit
Lot weight
Number of incremental samples
(tonnes)
≤ 0.1
> 0.1 - ≤ 0.2
> 0.2 - ≤ 0.5
> 0.5 - ≤ 1.0
> 1.0 - ≤ 2.0
> 2.0 - ≤ 5.0
> 5.0 - ≤ 10.0
> 10.0 - ≤ 15.0
4.6 Sampling procedure for foods intended for infants and young children
The sampling procedure as mentioned for cereals and cereal products in point 4.5 of this
Schedule applies. This means that the number of incremental samples to be taken
depends on the weight of the lot, with a minimum of 10 and a maximum of 100, in
accordance with Table 2 at point 4.5.
-
The weight of the incremental sample should be about 100 grams. In case of lots
in retail packing, the weight of the incremental sample depends on the weight of
the retail packing.
-
Weight of aggregate sampling = 1 to 10 kg sufficiently mixed.
B
4.7. Sampling at retail stage
Sampling of foodstuffs at the retail stage should be done where possible in accordance
with the above sampling provisions. Where this is not possible, other effective sampling
procedures at retail stage can be used provided that they ensure sufficient
representativeness for the sampled lot.
5. Acceptance of a lot or sublot
Acceptance if the aggregate sample conforms to the maximum limit, taking into
account the measurement uncertainty and correction for recovery,
Rejection if the aggregate sample exceeds the maximum limit beyond reasonable
doubt, taking into account the measurement uncertainty and correction for
recovery.
1 The sampling for the official control of the levels of patulin Sampling and
analytical methods
in foodstuffs shall be carried out in accordance with the methods for patulin in
foodstuffs.
described in the Ninth Schedule to these regulations.
6.2 The sample preparation and methods of analyses used for
the official control of the levels of patulin in foodstuffs shall comply
with the criteria described in the Tenth Schedule to these regulations.
(Equivalent to Annex II of Commission Directive 2002/26/EC)
Sample Preparation and Criteria for Methods of Analysis used in Official Checking
of the Levels of Ochratoxin A in certain foodstuffs
1. Precautions
As the distribution of ochratoxin A is non-homogeneous, samples should be prepared —
and especially homogenised — with extreme care. All the material received by the
laboratory is to be used for the preparation of test material.
2. Treatment of the sample as received in the laboratory
Finely grind and mix thoroughly the complete aggregate sample using a process that has
been demonstrated to achieve complete homogenisation.
In case the maximum level applies to the dry matter, the dry matter content shall be
determined on a part of the homogenised sample, using a procedure that has been
demonstrated to determine accurately the dry matter content.
3. Subdivision of samples for enforcement and defence purposes
The replicate samples for enforcement, trade (defence) and referee purposes shall be
taken from the homogenised material unless this conflicts with other applicable rules on
sampling.
4. Method of analysis to be used by the laboratory and laboratory control
requirements
4.1. Definitions
A number of the most commonly used definitions that the laboratory will be required to
use are given below
The most commonly quoted precision parameters are repeatability and reproducibility.
r=
Repeatability, the value below which the absolute difference between two
single test results obtained under repeatability conditions (i.e. same
sample, same operator, same apparatus, same laboratory, and short
interval of time) may be expected to lie within a specific probability
(typically 95 %) and hence r = 2,8 × sr
sr= 1
Standard deviation, calculated from results generated under repeatability
conditions
B
Relative standard deviation, calculated from results generated under
s
−
repeatability conditions [ − r . 100 ] where x is the average of results over
x
all laboratories and samples
Reproducibility, the value below which the absolute difference between
single test results obtained under reproducibility conditions (i.e. on
identical material obtained by operators in different laboratories, using the
standardised test method) may be expected to lie within a certain
probability (typically 95 %); R = 2,8 × sR
Standard deviation, calculated from results under reproducibility
conditions
Relative standard deviation calculated from results generated under
S
reproducibility conditions [ r − . 100 ].
x
4.2. General requirements
Methods of analysis used for food control purposes must comply with the provisions of
items 1 and 2 of the Annex to Directive 85/591/EEC concerning the introduction of
Community methods of sampling and analysis for the monitoring of foodstuffs intended
for human consumption.
4.3. Specific requirements
Where no specific methods for the determination of ochratoxin A levels in foodstuffs are
prescribed at Community level, laboratories may select any method provided the selected
method meets the following criteria
Performance characteristics for ochratoxin A
Ochratoxin A
(µg/kg)
RSD r
RSD R
Recovery
(%)
(%)
(%)
≤ 40
≤ 60
50 to120
≤ 20
≤ 30
70 to110
The detection limits of the methods used are not stated as the precision values are
given at the concentrations of interest.
The precision values are calculated from the Horwitz equation
RSD R = 2 ( 1 − 0 . 5 log C )
where
—
RSD R is the relative standard deviation calculated from results generated
−
under reproducibility conditions [ ( S R x . 100 ],
—
C is the concentration ratio (i.e. 1 = 100 g/100 g, 0,001 = 1,000 mg/kg).
This is a generalised precision equation, which has been found to be independent
of analyte and matrix but solely dependent on concentration for most routine
methods of analysis.
4.4. Recovery calculation
The analytical result is to be reported corrected or uncorrected for recovery. The manner
of reporting and the level of recovery must be reported. The analytical result corrected for
recovery shall be used for checking compliance (see Fifth Schedule, point 5).
The analytical result has to be reported as x ± U, whereby x is the analytical result and U
is the expanded measurement uncertainty.
U is the expanded uncertainty, using a coverage factor of 2 which gives a level of
confidence of approximately 95 %.
4.5. Laboratory quality standards
Laboratories must comply with Directive 93/99/EEC on the subject of additional
measures concerning the official control of foodstuffs.
B
1 The Contaminants (Sampling and Analysis Methods) Repeal of L.N. 240
of 2003.
Regulations, 2003 are hereby repealed.
(Equivalent to Annex I of Commission Directive 2002/69/EC)
Methods of Sampling for Official Control of the Levels of Dioxins (PCDD/PCDF)
and the Determination of Dioxin-like PCBs in certain foodstuffs
1. Purpose and scope
Samples intended for the official control of the levels of dioxins (PCDD/PCDF) content,
as well for the determination of the content of dioxin-like PCBs ( 10 ) in foodstuffs shall be
taken according to the methods described below. Aggregate samples thus obtained shall
be considered as representative of the lots or sublots from which they are taken.
Compliance with maximum levels laid down in Commission Regulation (EC) No
466/2001 setting maximum levels for certain contaminants in foodstuffs shall be
established on the basis of the levels determined in the laboratory samples.
2. Definitions
Lot: an identifiable quantity of food delivered at one time and determined by the official
to have common characteristics, such as origin, variety, type of packing, packer,
consignor or markings. In the case of fish and fishery products, also the size of fish shall
be comparable.
Sublot: designated part of a large lot in order to apply the sampling method on that
designated part. Each sublot must be physically separated and identifiable.
Incremental sample: a quantity of material taken from a single place in the lot or sublot.
Aggregate sample: the combined total of all the incremental samples taken from the lot or
sublot.
Laboratory sample: a representative part/quantity of the aggregate sample intended for
the laboratory.
Table WHO TEFs for human risk assessment based on the conclusions of the World Health Organisation
meeting in Stockholm, Sweden, 15-18 June 1997 (Van den Berg et al., (1998) Toxic Equivalency Factors
(TEFs) for PCBs, PCDDs, PCDFs for Humans and for Wildlife. Environmental Health Perspectives,
106(12), 775).
Congener
TEF value
Dibenzo-p-dioxins (PCDDs)
2,3,7,8-TCDD
1,2,3,7,8-PeCDD
1,2,3,4,7,8-HxCDD
0.1
1,2,3,6,7,8-HxCDD
0.1
1,2,3,7,8,9-HxCDD
0.1
1,2,3,4,6,7,8-HpCDD
0.01
OCDD
0.0001
Dibenzofurans (PCDFs)
2,3,7,8-TCDF
0.1
1,2,3,7,8-PeCDF
0.05
2,3,4,7,8-PeCDF
0.5
1,2,3,4,7,8-HxCDF
0.1
1,2,3,6,7,8-HxCDF
0.1
1,2,3,7,8,9-HxCDF
0.1
2,3,4,6,7,8-HxCDF
0.1
1,2,3,4,6,7,8-HpCDF
0.01
1,2,3,4,7,8,9-HpCDF
0.01
OCDF
0.0001
‘Dioxin-like’ PCBs
Non-ortho PCBs + Mono-ortho PCBs
Non-ortho PCBs
PCB 77
0.0001
PCB 81
0.0001
PCB 126
0.1
PCB 169
0.01
Mono-ortho PCBs
PCB 105
0.0001
PCB 114
0.0005
PCB 118
0.0001
PCB 123
0.0001
PCB 156
0.0005
PCB 157
0.0005
PCB 167
0.00001
PCB 189
0.0001
Abbreviations used: T = tetra; Pe = penta; Hx = hexa; Hp = hepta; O = octa; CDD = chlorodibenzodioxin;
CDF = chlorodibenzofuran; CB = chlorobiphenyl
B
3. General provisions
3.1. Personnel
Sampling shall be performed by an authorised qualified person as specified by the Food
Safety Commission.
3.2. Material to be sampled
Each lot, which is to be examined, must be sampled separately.
3.3. Precautions to be taken
In the course of sampling and preparation of laboratory samples precautions must be
taken to avoid any changes, which would affect the content of dioxins and dioxin-like
PCBs, adversely affect the analytical determination or make the aggregate samples
unrepresentative.
3.4. Incremental samples
As far as practical incremental samples shall be taken at various places distributed
throughout the lot or sublot. Departure from this procedure must be recorded in the
record provided for under 3.8.
3.5. Preparation of the aggregate sample
The aggregate sample is made up by uniting all incremental samples. It shall be at least 1
kg unless not practical, e.g. when a single package has been sampled.
3.6. Subdivision of aggregate sample in laboratory samples for enforcement, defence and
referee purposes
The laboratory samples for enforcement, trade (defence) and referee purposes shall be
taken from the homogenised aggregate sample unless this conflicts with other provisions
on sampling. The size of the laboratory samples for enforcement shall be sufficient to
allow at least for duplicate analyses.
3.7. Packaging and transmission of aggregate and laboratory samples
Each aggregate and laboratory sample shall be placed in a clean, inert container offering
adequate protection from contamination, from loss of analytes by adsorption to the
internal wall of the container and against damage in transit. All necessary precautions
shall be taken to avoid change of composition of the aggregate and laboratory samples,
which might arise during transportation or storage.
3.8. Sealing and labelling of aggregate and laboratory samples
Each sample taken for official use shall be sealed at the place of sampling and identified
following the procedures established by the Food Safety Commission. A record must be
kept of each sampling, permitting each lot to be identified unambiguously and giving the
date and place of sampling together with any additional information likely to be of
assistance to the analyst.
4. Sampling plans
The sampling method applied shall ensure that the aggregate sample is representative for
the lot that is to be controlled.
Number of incremental samples
In the case of milk and oils, for which a homogeneous distribution of the contaminants in
question can be assumed within a given lot, it is sufficient to take three incremental
samples per lot which forms the aggregate sample. Reference to the lot number shall be
given. For other products, the minimum number of incremental samples to be taken from
the lot shall be as given in Table 1. The aggregate sample uniting all incremental samples
shall be at least 1 kg (see point 3.5). The incremental samples shall be of similar weight.
The weight of an incremental sample should be at least 100 grams. The weight of the
incremental sample is dependent on the size of the particles in the lot. Departure from this
procedure must be recorded in the record provided for under 3.8. In accordance with the
provisions of Commission Decision 97/747/EC of the 27 th October, 1997 fixing the levels
and frequencies of sampling provided for by Council Directive 96/23/EC for the
monitoring of certain substances and residues thereof in certain animal products ( 11 ), the
sample size for hen eggs is at least 12 eggs (for bulk lots as well for lots consisting of
individual packages, Tables 1 and 2).
TABLE 1
Minimum number of incremental samples to be taken from the lot
Weight of the lot (in kg)
Minimum number of incremental samples
to be taken
< 50
50 to 500
> 500
If the lot consists of individual packages, then the number of packages, which shall be
taken to form the aggregate sample, is given in Table 2.
TABLE 2
Number of packages (incremental samples) which shall be taken to form the
aggregate sample if the lot consists of individual packages
Number of packages or units in the lot
Number of packages or units to be taken
1 to 25
1 package or unit
26 to 100
about 5 %, at least 2 packages or units
> 100
about 5 %, at maximum 10 packages or
units
OJ L 303, 6.11.1997, p. 12.
B
Specific provisions for the sampling of lots containing whole fishes
The number of incremental samples to be taken from the lot is defined in Table 1. The
aggregate sample uniting all incremental samples shall be at least 1 kg (see point 3.5).
In case the lot to be sampled contains small fish (individual fish weighing < 1 kg),
the whole fish is taken as incremental sample to form the aggregate sample. In
case the resulting aggregate sample weighs more than 3 kg, the incremental
samples can consist of the middle part, weighing each at least 100 grams, of the
fish forming the aggregate sample. The whole part to which the maximum level is
applicable is used for homogenisation of the sample.
In case the lot to be sampled contains larger fish (individual fish weighing more
than 1 kg), the incremental sample consists of the middle part of the fish. Each
incremental sample weighs at least 100 grams. In case the lot to be sampled
consist of very large fish (e.g. > 6 kg) and taking a piece of the middle part of the
fish would result in significant economic damage, taking three incremental
samples of at least 350 grams each can be considered sufficient, independently of
the size of the lot.
5. Compliance of the lot or sublot with the specification
The lot is accepted if the analytical result of a single analysis does not exceed the
respective maximum level as laid down in Regulation (EC) No 466/2001, taking into
account the measurement uncertainty.
The lot is non-compliant with the maximum level as laid down in Regulation (EC) No
466/2001, if the analytical result confirmed by duplicate analysis and calculated as the
mean of at least two separate determinations exceeds the maximum level beyond
reasonable doubt, taking into account the measurement uncertainty.
The taking into account of the measurement uncertainty can be done according to one of
the following approaches
by calculating the expanded uncertainty, using a coverage factor of 2, which gives
a level of confidence of approximately 95 %,
by establishing the decision limit (CCα) according to the provisions of
Commission Decision 2002/657/EC of the 12 th August, 2002 implementing
Council Directive 96/23/EC concerning the performance of analytical methods
and the interpretation of results ( 12 ) (point 3.1.2.5 of the Annex — the case of
substances with established permitted levels).
OJ L 221, 17.8.2002, p. 8. Decision as last amended by Decision 2004/25/EC (OJ L 6, 10.1.2004, p. 38).
The present interpretation rules apply for the analytical result obtained on the sample for
official control. In case of analysis for defence or referee purposes, the national rules
apply.
B
Reporting of the result
Insofar as the used analytical procedure makes it possible, the analytical results should
contain the levels of the individual PCDD/F and PCB congeners and be reported as
lowerbound, upperbound and mediumbound in order to include a maximum of
information in the reporting of the results and thereby enabling the interpretation of the
results according to specific requirements.
The report should also include the lipid content of the sample as well the method used for
lipid extraction.
The recoveries of the individual internal standards must be made available in case the
recoveries are outside the range mentioned in point 6, in case the maximum level is
exceeded and in other cases upon request.
B
Sample Preparation and Requirements for Methods of Analysis used in Official
Control of the Levels of Dioxins (PCDD/PCDF) and the Determination of Dioxin-
like PCBs in certain foodstuffs
1. Objective and field of application
These requirements should be applied where foodstuffs are analysed for the official
control of the levels of dioxins (polychlorinated dibenzo-p-dioxins (PCDD) and
polychlorinated dibenzofurans (PCDF)) and the determination of dioxin-like PCBs.
Monitoring for the presence of dioxins in foodstuffs can be performed by a strategy
involving a screening method in order to select those samples with levels of dioxins and
dioxin-like PCBs that are less than 30-40 % below or exceed the level of interest. The
concentration of dioxins in those samples with significant levels needs to be
determined/confirmed by a confirmatory method.
Screening methods are methods that are used to detect the presence of dioxins and
dioxin-like PCBs at the level of interest. These methods have a capacity for a high sample
throughput and are used to sift large numbers of samples for potential positives. They are
specifically designed to avoid false negatives.
Confirmatory methods are methods that provide full or complementary information
enabling the dioxins and dioxin-like PCBs to be identified and quantified unequivocally
at the level of interest.
2. Background
Because environmental and biological samples (including samples of foodstuffs) in
general contain complex mixtures of different dioxin congeners, the concept of Toxic
Equivalency Factors (TEFs) has been developed to facilitate risk assessment. These TEFs
have been established to express concentrations of mixtures of 2,3,7,8-substituted PCDDs
and PCDFs, and more recently, some non-ortho and mono-ortho chlorine substituted
PCBs which possesses dioxin-like activity in toxic equivalents (TEQs) of 2,3,7,8-TCDD
(see Seventh Schedule, footnote 1).
The concentrations of the individual substances in a given sample are multiplied by their
respective TEF and subsequently summed to give the total concentration of dioxin-like
compounds expressed as TEQs.
The concept of ‘upperbound’ requires using the limit of quantification for the
contribution of each non-quantified congener to the TEQ.
The concept of ‘lowerbound’ requires using zero for the contribution of each non-
quantified congener to the TEQ.
The concept of ‘mediumbound’ requires using half of the limit of quantification
calculating the contribution of each non-quantified congener to the TEQ.
For the purposes of this Schedule only, the accepted specific limit of quantification of an
individual congener is the concentration of an analyte in the extract of a sample which
produces an instrumental response at two different ions, to be monitored with an S/N
(signal/noise) ratio of 3:1 for the less sensitive signal and fulfilment of the basic
requirements such as, e.g., retention time, isotope ratio according to the determination
procedure as described in EPA method 1613 revision B.
3. Quality assurance requirements to be complied with for sample preparation
Measures must be taken to avoid cross-contamination at each stage of the
sampling and analysis procedure.
The samples must be stored and transported in glass, aluminium, polypropylene
or polyethylene containers. Traces of paper dust must be removed from the
sample container. Glassware should be rinsed with solvents previously controlled
for the presence of dioxins.
The sample storage and transportation has to be performed in a way that
maintains the integrity of the foodstuff sample.
Insofar as relevant, finely grind and mix thoroughly each laboratory sample using
a process that has been demonstrated to achieve complete homogenisation (e.g.
ground to pass a 1 mm sieve); samples have to be dried before grinding if
moisture content is too high.
Perform a blank analysis by carrying out the entire analytical procedure omitting
only the sample.
Sample weight used for the extraction must be sufficient to fulfil the requirements
with respect to sensitivity.
There are many satisfactory specific sample preparation procedures, which may
be used for the products under consideration. The procedures have to be validated
according to internationally accepted guidelines.
4. Requirements for laboratories
Laboratories shall demonstrate the performance of a method in the range of the
level of interest, e.g. 0,5 ×, 1 × and 2 × the level of interest with an acceptable
coefficient of variation for repeated analysis. For details of acceptance criteria,
see point 5.
B
Limit of quantification for a confirmatory method should be in the range of about
one fifth of the level of interest, to make sure that acceptable coefficients of
variations are met in the range of the level of interest.
Regular blank controls and spiking experiments or analysis of control samples
(preferably, if available, certified reference material) should be performed as
internal quality control measures.
Successful participation in interlaboratory studies that assess laboratory
proficiency is the best way to prove the competence in specific analyses. However
successful participation in interlaboratory studies for, e.g. soil or sewage samples,
does not necessarily prove the competence also in the field of food or feedingstuff
samples, which present lower contamination levels. Therefore, the continuous
participation in interlaboratory studies for the determination of dioxins and
dioxin-like PCBs in the relevant feed/food matrices is mandatory.
In accordance with the provisions of Directive 93/99/EEC, laboratories should be
accredited by a recognised body operating in accordance with ISO Guide 58 to
ensure that they are applying analytical quality assurance. Laboratories should be
accredited following the ISO/IEC/17025:1999 standard.
5. Requirements to be met by analytical procedure for dioxinsand dioxin-like PCBs
Basic requirements for acceptance of analytical procedures
High sensitivity and low limits of detection. For PCDDs and PCDFs, detectable
quantities have to be in the picogram TEQ (10-12 g) range because of extreme
toxicity of some of these compounds. PCBs are known to occur at higher levels
than the PCDDs and PCDFs. For most PCB congeners sensitivity in the nanogram
(10-9 g) range is already sufficient. However, for the measurement of the more
toxic dioxin-like PCB congeners (in particular non-ortho substituted congeners),
the same sensitivity must be reached as for the PCDDs and PCDFs.
High selectivity (specificity). A distinction is required for PCDDs, PCDFs and
dioxin-like PCBs from a multitude of other, coextracted and possibly interfering
compounds present at concentrations up to several orders of magnitude higher
than those of the analytes of interest. For gas chromatography/mass spectrometry
(GC/MS) methods a differentiation among various congeners is necessary, such
as between toxic (e.g. the seventeen 2,3,7,8-substituted PCDDs and PCDFs and
dioxin-like PCBs) and other congeners. Bioassays should be able to determine
TEQ values selectively as the sum of PCDDs, PCDFs and dioxin-like PCBs.
High accuracy (trueness and precision). The determination should provide a valid
estimate of the true concentration in a sample. High accuracy (accuracy of the
measurement: the closeness of the agreement between the result of a measurement
with the true or assigned value of the measurement) is necessary to avoid the
rejection of a sample analysis result on the basis of poor reliability of the estimate
of TEQ. Accuracy is expressed as trueness (difference between the mean value
measured for an analyte in a certified material and its certified value, expressed as
percentage of this value) and precision (precision is usually calculated as a
standard deviation including repeatability and reproducibility, and indicates the
closeness of agreement between the results obtained by applying the experimental
procedure several times under prescribed conditions).
Screening methods can comprise bioassays and GC/MS methods; confirmatory
methods are high-resolution gas chromatography/high resolution mass
spectrometry (HRGC/HRMS) methods. Following criteria have to be complied
with on total TEQ value
Screening methods
Confirmatory methods
False negative rate
< 1 %
Trueness
-20 % to + 20 %
< 30 %
< 15 %
6. Specific requirements for GC/MS methods to be complied with for screening or
confirmatory purposes
Addition of 13 C-labelled 2,3,7,8-chlorine substituted internal PCDD/F standards
(and of 13 C-labelled internal dioxin-like PCB standards, if dioxin-like PCBs have
to be determined) must be carried out at the very beginning or start of the
analytical method e.g. prior to extraction in order to validate the analytical
procedure. At least one congener for each of the tetra to octa-chlorinated
homologous groups for PCDD/F (and at least one congener for each of the
homologous groups for dioxin-like PCBs, if dioxin-like PCBs have to be
determined) must be added (alternatively, at least one congener for each mass
spectrometric selected ion recording function used for monitoring PCDD/F and
dioxin-like PCBs). There is a clear preference, certainly in case of confirmatory
methods, of using all 17 13 C-labelled 2,3,7,8-substituted internal PCDD/F
standards and all 12 13 C-labelled internal dioxin-like PCB standard (if dioxin-like
PCBs have to be determined).
Relative response factors should also be determined for those congeners for which
no 13 C-labelled analogue is added by using appropriate calibration solutions.
For foodstuffs of plant origin and foodstuffs of animal origin containing less than
10 % fat, the addition of the internal standards is mandatory prior to extraction.
For foodstuffs of animal origin containing more than 10 % fat, the internal
standards can be added either before extraction or after fat extraction. An
appropriate validation of the extraction efficiency should be carried out,
depending on the stage at which internal standards are introduced and on whether
results are reported on product or fat basis.
B
Prior to GC/MS analysis, 1 or 2 recovery (surrogate) standard(s) must be added.
Control of recovery is necessary. For confirmatory methods, the recoveries of the
individual internal standards should be in the range of 60 % to 120 %. Lower or
higher recoveries for individual congeners, in particular for some hepta- and octa-
chlorinated dibenzodioxins and dibenzofurans, are acceptable on the condition
that their contribution to the TEQ value does not exceed 10 % of the total TEQ
value (based on PCDD/F only). For screening methods, the recoveries should be
in the range of 30 % to 140 %.
Separation of dioxins from interfering chlorinated compounds such as PCBs and
chlorinated diphenyl ethers should be carried out by suitable chromatographic
techniques (preferably with a florisil, alumina and/or carbon column).
Gas chromatographic separation of isomers should be sufficient (< 25 % peak to
peak between 1,2,3,4,7,8-HxCDF and 1,2,3,6,7,8-HxCDF).
Determination should be performed according to EPA Method 1613 revision B
Tetra- through octa-chlorinated dioxins and furans by isotope dilution
HRGC/HRMS or another with equivalent performance criteria.
The difference between upperbound level and lower bound level should not
exceed 20 % for foodstuffs with a dioxin contamination of about 1 pg WHO-
TEQ/g fat (based on PCDD/PCDF only). For foodstuffs with a low fat content,
the same requirements for contamination levels of about 1 pg WHO-TEQ/g
product have to be applied. For lower contamination levels, for example 0,50 pg
WHO-TEQ/g product, the difference between upperbound and lowerbound level
may be in the range of 25 to 40 %.
7. Screening methods of analysis
7.1. Introduction
Different analytical approaches can be performed using a screening method: a pure
screening approach and a quantitative approach.
Screening approach
The response of samples is compared to that of a reference sample at the level of interest.
Samples with a response less than the reference are declared negative, those with a higher
response are suspected positives. Requirements
A blank and a reference sample(s) have to be included in each test series, which is
extracted and tested at the same time under identical conditions. The reference
sample must show a clearly elevated response in comparison to a blank.
Extra reference samples 0,5 × and 2 × the level of interest should be included to
demonstrate the proper performance of the test in the range of interest for the
control of the level of interest.
When testing other matrices, the suitability of the reference sample(s) has to be
demonstrated, preferentially by including samples shown by HRGC/HRMS to
contain a TEQ level around that of the reference sample or else a blank spiked at
this level.
Since no internal standards can be used in bioassays, tests on repeatability are
very important to obtain information on the standard deviation within one test
series. The coefficient of variation should be below 30 %.
For bioassays, the target compounds, possible interferences and maximum
tolerable blank levels should be defined.
Quantitative approach
The quantitative approach requires standard dilution series, duplicate or triplicate clean
up and measuring as well as blank and recovery controls. The result may be expressed as
TEQ, thereby assuming that the compounds responsible for the signal correspond to the
TEQ principle. This can be performed by using TCDD (or a dioxin/furan standard
mixture) to produce a calibration curve to calculate the TEQ level in the extract and thus
in the sample. This is subsequently corrected for the TEQ level calculated for a blank
sample (to account for impurities from solvents and chemicals used), and a recovery
(calculated from the TEQ level in a quality control sample around the level of interest). It
is essential to note that part of the apparent recovery loss may be due to matrix effects
and/or differences between the TEF values in the bioassays and the official TEF values
set by WHO.
7.2. Requirements for methods of analysis used for screening
GC/MS methods of analysis and bioassays may be used for screening. For
GC/MS methods the requirements as laid down in point 6 are to be used. For cell
based bioassays specific requirements are laid down in point 7.3 and for kit-based
bioassays in point 7.4.
Information on the number of false-positive and false-negative results of a large
set of samples below and above the maximum level or action level is necessary, in
comparison to the TEQ content as determined by a confirmatory method of
analysis. Actual false negative rates should be under 1 %. The rate of false
positive samples should be low enough to make the use of a screening tool
advantageous.
Positive results have always to be confirmed by a confirmatory method of
analysis (HRGC/HRMS). In addition, samples from a wide TEQ-range should be
B
confirmed by HRGC/HRMS (approximately 2 % to 10 % of the negative
samples). Information on correspondence between bioassay and HRGC/HRMS
results should be made available.
7.3. Specific requirements for cell-based bioassays
When performing a bioassay, every test run requires a series of reference
concentrations of TCDD or a dioxin/furan mixture (full dose-response curve with
a R2 > 0,95). However, for screening purposes an expanded low level curve for
analysing low level samples could be used.
A TCDD reference concentration (about 3 × limit of quantification) on a quality
control sheet should be used for the outcome of the bioassay over a constant time
period. An alternative could be the relative response of a reference sample in
comparison to the TCDD calibration line since the response of the cells may
depend on many factors.
Quality control (QC) charts for each type of reference material should be recorded
and checked to make sure the outcome is in accordance with the stated guidelines.
In particular for quantitative calculations, the induction of the sample dilution
used must be within the linear portion of the response curve. Samples above the
linear portion of the response curve must be diluted and re-tested. Therefore, at
least three or more dilutions at one time are recommended to be tested.
The percent standard deviation should not be above 15 % in a triplicate
determination for each sample dilution and not above 30 % between three
independent experiments.
The limit of detection may be set as 3 × the standard deviation of the solvent
blank or of the background response. Another approach is to apply a response that
is above the background (induction factor 5 × the solvent blank) calculated from
the calibration curve of the day. The limit of quantification may be set as 5 × to 6
× the standard deviation of the solvent blank or of the background response or to
apply a response that is above the background (induction factor 10 × the solvent
blank) calculated from the calibration curve of the day.
7.4. Specific requirements for kit-based bioassays ( 13 )
Manufacturer's instructions for sample preparation and analyses have to be
followed.
No evidence have yet been submitted of commercially available kit-based bioassays having sufficient
sensitivity and reliability to be used for screening for the presence of dioxins at the required levels in
samples of foodstuffs and feedingstuffs.
Test kits should not be used after the expiration date.
Materials or components designed for use with other kits should not be used.
Test kits should be kept within the specified range of storage temperature and
used at the specified operating temperature.
The limit of detection for immunoassays is determined as 3 × the standard
deviation, based on 10 replicate analysis of the blank, to be divided by the slope
value of the linear regression equation.
Reference standards should be used for tests at the laboratory to make sure that
the responsiveness to the standard is within an acceptable range.
(Equivalent to Annex I of Commission Directive 2003/78/EC)
Methods of Sampling for Official Control of the Levels of Patulin in certain
foodstuffs
1. Purpose and scope
Samples intended for official checking of the levels of patulin in foodstuffs shall be taken
according to the methods described below. Aggregate samples thus obtained shall be
considered as representative of the lots. Compliance with maximum levels laid down in
Commission Regulation (EC) No 466/2001 shall be established on the basis of the levels
determined in the laboratory samples.
2. Definitions
Lot
an identifiable quantity of a food commodity delivered at one time
and having been determined by the official to have common
characteristics, such as origin, variety, type of packing, packer,
consignor or markings.
Sublot
designated part of a lot in order to apply the sampling method on
that designated part. Each sublot must be physically separate and
identifiable.
Incremental sample: a quantity of material taken from a single place in the lot or sublot.
Aggregate sample
the combined total of all the incremental samples taken from the
lot or sublot.
3. General provisions
3.1. Personnel
Sampling shall be performed by an authorised person as specified by the Food Safety
Commission.
3.2. Material to be sampled
Each lot which is to be examined must be sampled separately.
3.3. Precautions to be taken
In the course of sampling and preparation of the samples precautions must be taken to
avoid any changes, which would affect the patulin content, adversely affect the analytical
determination or make the aggregate samples unrepresentative.
3.4. Incremental samples
As far as possible incremental samples should be taken at various places distributed
throughout the lot or sublot. Departure from this procedure must be recorded in the
record.
3.5. Preparation of the aggregate sample
The aggregate sample is made up by uniting the incremental samples. It shall be at least 1
kg unless not practical e.g. when a single package has been sampled.
3.6. Replicate samples
Replicate samples for enforcement, trade (defence) and referee purposes shall be taken
from the homogenised aggregate sample unless this conflicts with other provisions on
sampling.
3.7. Packaging and transmission of samples
Each sample shall be placed in a clean, inert container offering adequate protection from
contamination and against damage in transit. All necessary precautions shall be taken to
avoid any change in composition of the sample, which might arise during transportation
or storage.
3.8. Sealing and labelling of samples
Each sample taken for official use shall be sealed at the place of sampling and identified
following the procedures established by the Food Safety Commission.
A record must be kept of each sampling, permitting each lot to be identified
unambiguously and giving the date and place of sampling together with any additional
information likely to be of assistance to the analyst.
4. Sampling plans
The sampling method applied shall ensure that the aggregate sample is representative for
the lot that is to be controlled.
Number of incremental samples
The aggregate sample shall be at least 1 kg (see point 3.5), except where it is not possible
e.g. when sampling a single package.
The minimum number of incremental samples to be taken from the lot shall be as given
in Table 1. In the case of liquid products the lot shall be thoroughly mixed insofar as
possible by either manual or mechanical means immediately prior to sampling. In this
B
case, a homogeneous distribution of patulin can be assumed within a given lot. It is
therefore sufficient to take three incremental samples from a lot to form the aggregate
sample.
The incremental samples shall be of similar weight. The weight of an incremental sample
should be at least 100 grams, resulting in an aggregate sample of at least 1 kg. Departure
from this procedure must be recorded in the record provided for under 3.8.
Table 1
Minimum number of incremental samples to be taken from the lot
Weight of lot (in kg)
Minimum number of incremental samples
to be taken
< 50
50 to 500
> 500
If the lot consists of individual packages, then the number of packages, which shall be
taken to form the aggregate sample, is given in Table 2.
Table 2
Number of packages (incremental samples) which shall be taken to form the
aggregate sample if the lot consists of individual packages
Number of packages or units in the lot
Number of packages or units to be taken
1 to 25
1 package or unit
26 to 100
about 5 %, at least 2 packages or units
> 100
about 5 %, at maximum 10 packages or
units
5. Compliance of the lot or sublot with the specification
The control laboratory shall analyse the laboratory sample for enforcement in duplicate
analysis in case the obtained result of the first analysis is less than 20 % below or above
the maximum level, and calculate the mean of the results.
The lot is accepted if the result of the first analysis is more than 20 % below the
maximum level or, where duplicate analysis is necessary, if the mean does not exceed the
respective maximum level as laid down in Regulation (EC) No 466/2001 taking into
account the measurement uncertainty and correction for recovery.
The lot is non-compliant with the maximum level as laid down in Regulation (EC) No
466/2001, if the mean, corrected for recovery exceeds the maximum level beyond
reasonable doubt taking into account the measurement uncertainty.
Sample Preparation and Criteria for Methods of Analysis used in Official Checking
of the Levels of Patulin in certain foodstuffs
1. Precautions
As the distribution of patulin in certain foodstuffs could be non-homogeneous, samples
should be prepared — and especially homogenised — with extreme care.
All the material received by the laboratory is to be used for the preparation of test
material.
2. Treatment of the sample as received in the laboratory
Finely grind (insofar relevant) and mix thoroughly the complete aggregate sample using a
process that has been demonstrated to achieve complete homogenisation.
3. Subdivision of samples for enforcement and defence purposes
The replicate samples for enforcement, trade (defence) and referee purposes shall be
taken from the homogenised material unless this conflicts with other provisions on
sampling.
4. Method of analysis to be used by the laboratory and laboratory control
requirements
4.1. Definitions
A number of the most commonly used definitions that the laboratory will be required to
use are given below.
The most commonly quoted precision parameters are repeatability and reproducibility.
r =
Repeatability, the value below which the absolute difference between two
single test results obtained under repeatability conditions (i.e. same
sample, same operator, same apparatus, same laboratory, and short
interval of time) may be expected to lie within a specific probability
(typically 95 %) and hence r = 2,8 x s r .
s r =
Standard deviation, calculated from results generated under repeatability
conditions.
B
Relative standard deviation, calculated from results generated under
s
−
repeatability conditions [ − r . 100 ] where x is the average of results over
x
all laboratories and samples.
Reproducibility, the value below which the absolute difference between
single test results obtained under reproducibility conditions (i.e. on
identical material obtained by operators in different laboratories, using the
standardised test method) may be expected to lie within a certain
probability (typically 95 %); R = 2,8 x s R .
Standard deviation, calculated from results under reproducibility
conditions.
Relative standard deviation calculated from results generated under
s
reproducibility conditions [ − r . 100 ].
x
4.2. General requirements
Methods of analysis used for food control purposes must comply with the provisions of
items 1 and 2 of the Annex to Council Directive 85/591/EEC of the 20 th December, 1985
concerning the introduction of Community methods of sampling and analysis for the
monitoring of foodstuffs intended for human consumption ( 14 ).
4.3. Specific requirements
Where no specific methods for the determination of patulin in foodstuffs are prescribed at
Community level, laboratories may select any method provided the selected method
meets the following criteria
Patulin
RSD r %
RSD R %
Recovery %
≤ 30
≤ 40
50 to120
≤ 20
≤ 30
70 to105
≤ 15
≤ 25
75 to 105
The detection limits of the methods used are not stated as the precision values are given
at the concentrations of interest.
The precision values are calculated from the Horwitz equation
OJ L 372, 31.12.1985, p. 50.
RSD R = 2 ( 1 − 0 . 5 log C )
where
—
RSD R is the relative standard deviation calculated from results generated under
−
reproducibility conditions [ ( S R x . 100 ] .
—
C is the concentration ratio (i.e. 1 = 100g/100g, 0,001 = 1,000 mg/kg)
This is a generalised precision equation, which has been found to be independent of
analyte and matrix but solely dependent on concentration for most routine methods of
analysis.
4.4. Recovery calculation and reporting of results
The analytical result is to be reported corrected or uncorrected for recovery. The manner
of reporting and the level of recovery must be reported. The analytical result corrected for
recovery is used for checking compliance (see Annex I, point 5).
The analytical result has to be reported as x ± U whereby x is the analytical result and U
is the measurement uncertainty.
4.5. Laboratory quality standards
Laboratories must comply with Council Directive 93/99/EEC of 29 th October, 1993 on
the subject of additional measures concerning the official control of foodstuffs.