Legislator Case Law & Legislation
ln_1980_72 MT

Regulations, 1980

4 Articles / Provisions · Malta
Open official source Machine-readable Markdown (.md)

Statutory Text (4 Articles)

Malta Government Gazette — Legal Notice 1980 72 — Regulations, 1980

L.N. 72 of 1980

BUILDING (PRICE CONTROL) ACT, 1980

(ACT NO. XXVI OF 1980)

Building (Price Control) (Concrete Work and Masonry Work)

Regulations, 1980

IN exercise of the powers conferred by section 3 of the Building

(Price Control) Act 1980, the Minister of Works and Sport

has made

.

the fol1owing regulations:-

l. These regulations may be cited as the Building (Price Control)

(Concrete Work and Masonry Work) Regulations, 1980.

Gazzetta tal-Gvern ta' Malta — Avviż Legali 1980 72 — Kondos u Ġebel)

dwar il-Kontroll tal-Prezzijiet tal-Bini (Xogħol ta' Konkos u Ġebel).

Malta Government Gazette — Legal Notice 1980 72 — Regulations, 1980

Regulation 2

First Column

Concrete Work

l.

Reinforced concrete suspended slab; 0.15m thick, 1 :2:4

mix (Grade 20), including one layer of BRC mesh reinforce­

ment No. 1 06 and all necessary form work

Masonry Work

2. (a) Single Walls

Soft stone ashlar in lime mortar in

-

single walls 0.15m to 0.23m thick fair faced both sides and

cut to uniform height ...

(b) Double Walls - Soft stone ashlar in double walls

from 0.375m to 0.6m thick in lirne mortar consisting of inner

and outer skin not less than 0.15m thick well bonded

together, fair faced both sides and cut to uniform height

(c)

Foundations in Masonry Work -

for single walls ...

(i)

(ii)

for double walls

Notes

(1 ) The a bove prices apply to buildings of a height up to two storeys and

include the stairwell leading to the roof thereof, parapet wall surrounding the roof,

ventilators and plain projections, but do not inc1ude omamental work such as moulded

cornices and projections, moulded facias and si1ls, corbels, arches and balustrades.

For works above 1st floor level the above rates shaH be increased by the fol1owing

rates:-

at 2nd floor level

at 3rd floor level

15%

at 4th and 5th floor level

l7t%

(2) All openings not exceeding 1.2m in width shaH not be deducted in the

calculation of areas. No charge shaB be made for lintels, jambs and arrises thereof.

(3) For openings wider than 1.2m which have lintels, jambs and arrises, onJy the

width exceeding 1.2m shaH be deducted in the calculation of :-treas. A charge sha11 oniy

be made for the lintel in excess of 1.2m.

Ippubblikat

mid.Dipartiment

ta'

I·Informazzjoni

PlIblished

by

the

Department

,;}

Infurmatioll

-

fi-U.ċ.S.

Stampcrija tal-Gvern

Stampat

Printing Press

Printed

af

the

C,O.S.

GovCF/I!ll('1l1

--

-

-

-

Malta Government Gazette — Legal Notice 1980 72 — Regulations, 1980

The prices for works specified in the first column of the Sche-

dule to these regulations shall be those established in the second column

thereof.

Need to analyze how this provision applies to your matter?

Cross-reference this statute against case law, commentaries, and related legislative provisions inside Legislator AI.

Open in Legislator →