Water for Lead·Acid Batteries Order, 1980
Table of Provisions (7)
Statutory Text (7 Articles)
L.N. 101 of 1980
QUALITY CONTROL (EXPORTS, IMPORTS
AND LOCAL GOODS) ACT, 1971
(ACT NO. XIII OF 1971)
Water for Lead·Acid Batteries Order, 1980
(Order No. M7 of 1980)
IN exercise of the powers conferred by section 3 of Quality Control
(Exports, Imports and Loca1 Goods) Act, 197 1 , and in accordance with
that section, the Malta Board of Standards has made the following order.
1. This order may be cited as the Water for Lead-Acid Bat·
Citation and
commencem ent.
teries Order, 1980 , and may be referred to as Order No. M 7 of 1980 .
1.2. This order shall become operative on a date after the lapse
of 20 days from the day on which it is la id on the tab le of the House
of Representatives which date shall be notified by the Board in the
Gazette.
1. This order applies only to disti11ed water sold in bottles or in
S cope.
bulk and nonnally used in lead-acid batteries or for other industrial
purposes.
Characteristics
1. The finished product sold as water
for lead-acid batteries
of water.
should have the following characteristics
3.1.1. The water shall be purified by disti11ation, ion exchange
or other suitable process.
3.1.2.
It shall be clear when viewed through
a depth of
300 mm.
3.1 .3. Conductivity. The water shalI have
a
conductivity
not greater than 10 mho/cm.
3.1.4. Manganese content. The
water
shall
not
contain
mor e than 0.1 mg of mang anese/Kg.
3.1.5. Ammoniacal nitrogen content. The material shall not
contain more than 10 mg of ammoniacal nitrogen, expressed as
NH3, per kilogram, detennined and calculated by the method des
cribed in paragraph 6 .
3.1 .6. Nitrogen oxides content. The material shall not con
tain more than 3 mg of nitrogen oxides, expressed as N, per kilo
gram, determined and ca1culated by the method described in para
graph 6.
3.1.7. Iron content. The material shall not contain more
than 5 mg of iron, expressed as Fe, per kilogram, detennined and
calculated by the method described in paragraph 6.
3.1 .8. Copper content. The materjal shall not contain more
than 5 mg of copper, expressed as Cu, per kilogram, determined
and calculated by the method described in paragraph 6.
1. Every container of 'Distilled Water' should have a label show-
Labelling.
ing in clear and distinct print the following infonnation:-
4.1.1. the fact that the container contains "Water for Lead-
Acid Batteries";
4.1.2.
the net volume of the contents in metric units;
the brand name or trade mark or,
4.1.3.
the name and address of the manufacturer;
4.1.4.
4.1.5. where the brand name is not entered in a list kept by
the Director of Industry nor is the trade mark registered with the
Comptroller of Industrial Property, the inclusion in the label of the
name and address of the manufacturer shall be compulsory;
4.1.6.
the fact that it confonns with Order No. M7 of 1980.
1.
Each container should be sealed in a suitable manner.
1. The determinations referred to in paragraph 3.1.3. to 3.1.8
are to be carried out as described in the appendix of B.S. 4974 of 1975.
l-Inforroazz.loni
lhe Departmenl 0/ Jn/urmullOn
Ippubblikat mid· Dipartiment ta'
Published by
-
n-u.c.s.
Stamperlja tal-Gvern
Prlmed at
Ih. C.O.S.
- Governmelfl Primill/l Pre68
-
-
-